 共查询到18条相似文献,搜索用时 125 毫秒
1.
目的 探讨CT低剂量联合迭代算法在输尿管结石诊断中的应用价值.方法 90例输尿管结石患者在首次检查均应用常规剂量扫描(120 kV,400 mAs),采用滤波反投影算法(FBP)薄层重组,保守治疗后结石未排出.复查CT应用低剂量扫描随机分为3组(A组:120 kV,200 mAs;B组:120 kV,150 mAs;C组:120 kV,100 mAs)后分别行6级迭代算法薄层重组.由2名放射医师采用双盲法读片并对图像质量做主观评分,记录CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP),计算辐射有效剂量(ED);测量图像的客观噪声值,计算信噪比,测量结石CT值及最大长径,记录结石检出数.结果 常规组:CTDIvol(23.51±0.79) mGy,DLP(1166.38±52.78)mGy·cm,ED(17.50±0.79)mSv;A组:CTDIvol(11.78±0.38) mGy,DLP(584.68±25.47) mGy· cm,ED(8.77±0.38) mSv;B组:CTDIvol(8.34±0.13)mGy,DLP(462.87±24.76) mGy· em,ED(6.94±0.37)mSv;C组:CTDIvol(5.47±0.21) mGy,DLP(268.20±19.03)mGy·cm,ED(4.02±0.29) mSv;各组低剂量迭代算法重组的iDose l ~6图像结石检出数、结石CT值及大小与常规剂量比较差异无统计学意义(P>0.05);A组低剂量迭代算法重组的iDose4图像噪声(SD)、信噪比(SNR)及iDose 4—6图像质量主观评分与常规剂量比较差异无统计学意义(P>0.05);B组低剂量迭代算法重建的iDose6图像噪声、信噪比及图像质量主观评分与常规剂量比较差异无统计学意义(P>0.05);C组低剂量迭代算法重建的iDose l~6各组图像噪声、信噪比及图像质量主观评分与常规剂量比较差异有统计学意义(P<0.05).结论 CT低剂量扫描联合迭代算法诊断输尿管结石是可行的,可以在不影响图像质量的前提下明显减低辐射剂量.管电压120 kV情况下,在iDose6水平管电流150mAs为最低临界扫描参数.  相似文献   

2.
目的 探讨两种不同扫描方案下泌尿系统正常人群64层螺旋CT尿路成像(MSCTU)的图像质量和辐射剂量.方法 回顾性分析40名行64层MSCTU且最终证实无泌尿系统疾患的正常人群影像资料,CT扫描包括四期图像(平扫期、皮质期、髓质期、5分钟延迟期),延迟扫描分2组(120 kV组和100 kV组),每组20名,均采用CARE Dose 4D技术,参照管电流175 mAs.将2组延迟期图像的辐射剂量[平均容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效剂量(ED)]和图像质量[信噪比(SNR)、对比噪声比(CNR)、5分法图像质量评分]进行对照分析.结果 120 kV组和100 kV组泌尿系统延迟期图像CTDIvol分别为(7.04±1.07) mGy和(4.60±0.66)mGy,DLP分别为(308.80±60.00) mGy·om和(201.80 ±34.86)mGy·cm,ED分别为(4.63 ±0.90)mSy和(3.03 ±0.52)mSv,两组比较,在100 kV组辐射剂量明显低于120 kV组,差异有显著统计学意义(P均=0.000),而图像质量SNR分别为(102.34 ±29.66)和(109.87±33.21),CNR分别为(94.51 ±28.42)和(103.33±32.91),平均图像质量评分分别为(3.93 ±0.73)和(3.90±0.58),两组图像质量比较差异无统计学意义(P均>0.05).结论 MSCTU延迟期采用100 kV结合CARE Dose 4D技术能在不影响图像质量的前提下明显减少辐射剂量.  相似文献   

3.
目的:对比分析双源CT Flash扫描技术在新型冠状病毒肺炎(简称新冠肺炎)重症患者检查中的应用价值。方法:选择在我院行双源CT检查的100例新冠肺炎重症患者,分为研究组和对照组各50例,研究组采用Flash扫描技术,对照对采用常规剂量扫描技术,对比2组的检查时间、容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED),并比较2组图像的SNR及图像质量优良率。结果:研究组平均检查时间为(0.84±0.14)s,对照组(3.65±0.89)s,差异有统计学意义(P0.01)。研究组CTDIvol、DLP、ED平均值分别为(2.97±0.55)mGy、(106.33±22.63)mGy·cm、(1.49±0.32)mSv,对照组分别为(9.39±4.82)mGy、(290.52±64.28)mGy·cm、(4.07±0.91)mGy,2组差异均有统计学意义(均P0.01)。研究组3处测量点的SNR与对照组比较,差异均无统计学意义(均P 0.05)。研究组图像质量优良率为100.0%,高于对照组的92.0%,差异有统计学意义(P0.05)。结论:对新冠肺炎重症患者采用双源CT Flash扫描技术,可明显缩短检查时间,有效降低辐射剂量水平,且提高图像质量,值得临床推广使用。  相似文献   

4.
目的 探讨双源CT肺动脉成像双能量扫描与普通扫描(单能量扫描)对图像质量及辐射剂量的影响.方法 临床怀疑肺栓塞并行炫速双源CT肺动脉成像单、双能量扫描患者各61例,按扫描方式不同分为A、B2组,A组为双能量扫描(80/Sn140 kV),B组为普通扫描(Care kV选择输出管电压).对2组图像进行图像质量评分及测量2组肺动脉CT值、空气标准差(背景噪声)并计算信噪比(SNR),同时对2组图像的辐射剂量进行对比分析,以P<0.05为具有统计学意义.结果 2组图像质量主观评分2名观察者间一致性较好,Kappa分别为0.705、0.827,2组图像质量评分差异无统计学意义(P>0.05);A组右下肺动脉CT值高于B组,差异有统计学意义(P<0.05),其余肺动脉的CT值差异均无统计学意义(P>0.05);A组图像噪声稍高于B组,SNR稍低于B组,差异无统计学意义(P>0.05);A、B2组CT剂量指数(CTDIvol)、剂量长度乘积(DLP)有效剂量(ED)分别为(6.13± 1.09)mGy和(12.41±3.42) mGy、(172.49士41.35)mGy· cm和(332.16±115.65) mGy.cm、(2.41±0.58) mSv和(4.65±1.62) mSv,差异具有统计学意义(P=0.000),A组CTDIvol、DLP、ED较B组分别减少50.60%、48.07%、48.17%.结论 双源CT肺动脉成像双能量扫描(80/Sn140 kV)的图像质量与单能量扫描相近,X线辐射剂量较单能量扫描明显降低.  相似文献   

5.
目的:探讨低管电流联合 SAFIRE 重建的双能量 CT 扫描在颈部肿大淋巴结诊断中的应用。方法经病理证实的50例颈部肿大淋巴结的患者,进行常规 CT 平扫及双能量动脉期扫描,将其随机分为2组,即实验组和对照组,每组25例。实验组管电压分别为100 kV 和 Sn140 kV,管电流分别为117 mAs 和109 mAs,图像重建采用 SAFIRE 迭代重建技术,值选3;对照组管电压分别为100 kV 和 Sn140 kV,管电流分别为189 mAs 和165 mAs,1.0 cm,图像重建算法采用滤波反投影(FBP)技术,其余参数均相同。由2名有经验的医师对2组图像质量进行双盲法评分,利用 Kappa 检验比较观察者间评分的一致性;采用独立样本 t 检验比较2组患者的图像质量及有效辐射剂量。结果2组患者平均 CT 值的比较无统计学差异(P >0.05);2组噪声及信噪比(SNR)的比较有统计学差异(t 分别为4.705、4.403,P 分别为0.0008、0.0007);2组对比噪声比(CNR)无统计学差异(P >0.05);2组图像主观评分一致性较好(Kappa=0.720)且无统计学差异(P >0.05);实验组容积 CT 剂量指数(CTDIvol)为(10.801±0.594)mGy,剂量长度乘积(DLP)为(270.317±5.439)mGy·cm,有效辐射剂量(ED)为(1.594±0.031)mSv,对照组 CTDIvol 为(18.870±0.356)mGy, DLP 为(464.560±1.577)mGy·cm,ED 为(2.741±0.009)mSv,实验组 ED 较对照组降低约41.8%,且2组差异均有统计学意义(P <0.05)。结论在颈部肿大淋巴结的双能量扫描中,低管电流联合 SAFIRE 迭代重建能够在保证图像质量的同时,降低受检者所接受的辐射剂量。  相似文献   

6.
目的 探讨64层CT低剂量扫描在胸主动脉CT血管造影(CTA)成像中的临床应用研究。方法 应用64层CT对100例胸厚为22~23cm疑似胸主动脉疾病的患者分成5组进行胸主动脉CTA扫描,扫描范围为250~300mm,扫描条件为机器默认的120kV、350mAs,然后固定120kV,用300mAs、250mAs、200mAs及150mAs对其它四组患者进行扫描,记录不同mAs的CTDIvol及DLP,并转换为有效剂量ED。2位影像学家对上述图像进行SNR、CNR及主观评价。结果 将120kV、350mAs及300mAs、250mAs、200mAs及150mAs扫描产生的图像传至机器工作站进行SNR及CNR计算,其值分别为:4.81、4.02、2.59、1.73、1.57和3.81、3.27、1.86、0.92、0.94。2位影像学家对120kV下350~150mAs主观评价分值分别为:4.61±0.72,4.48±0.30,4.52±0.28,4.28±0.36,3.65±0.38;其CTDIvol、DLP分别为:10.08mGy、8.73mGy、7.14mGy、5.68mGy、4.21mGy和352.8mGy、309.32mGy、255.46mGy、203.8mGy、171.08mGy,将DLP转换为ED为5.29mSv、4.64mSv、3.83mSv、3.06mSv、2.57mSv。对上述数据进行单因素方差分析,200mAs和350mAs、300mAs、250mAs产生的影像质量没有明显差异,但200mAs的CTDIvol、DLP及ED较350mAs分别低43.7%、42.2%及43.7%。结论 胸厚为22~23cm的患者进行胸主动脉CTA扫描推荐mAs为200mAs。对于体型较小(肌肉较少)或有肺气肿等疾病可以选用150mAs及以下条件进行扫描。  相似文献   

7.
田葵  余辉山  沙晋璐   《放射学实践》2013,(10):1069-1072
目的:探索耐多药肺结核(MDR-TB)患者低剂量CT定位下空洞注药术的临床应用价值。方法:2006年1月-2011年12月在本院就诊的痰菌阳性耐药空洞型肺结核病例154例,随机分为低剂量CT(30mA)定位下空洞介入治疗组(78例)及常规剂量CT(150mA)定位下空洞介入治疗组(76例)。常规消毒麻醉,在CT导向下根据自制定位铅栅选择合适穿刺点、进针角度及路径后行空洞内联合灌注给药。比较两种不同剂量CT扫描在总辐射量、图像质量、穿刺治疗成功率、并发症发生率及临床疗效方面有何差异。结果:低剂量CT介入治疗组的CTDIvol 0.99mGy,DLP(14.20±1.46)mGy·cm;ED(0.199±0.02)mSv;常规剂量组CTDIvol 4.92mGy,DLP(75.92±7.42)mGy·cm;ED(1.06±0.10)mSv。统计学结果示两组患者的辐射量有显著性差异(t=-71.18,P=0.00);但在图像质量可接受性方面,两组患者的图像均为100%(评分均>2分);关于穿刺成功率及患者的远期疗效,低剂量组与常规剂量组相比差异无显著性(P>0.05)。结论:低剂量CT引导下的空洞注药技术在大大降低辐射量的同时既保障了穿刺治疗的成功,又促进了MDR-TB患者的疾病转归,因此值得在临床上普遍开展。  相似文献   

8.
目的:探讨低浓度等渗对比剂联合应用80 kV 和自适应统计迭代重建(ASiR)技术,对支气管动脉(BA)CT 血管成像(CTA)的价值。方法随机选取本院40例欲行 CT 增强检查的肺癌患者,18.5 kg/m2≤体质量指数(BMI)≤25 kg/m2。随机分为80 kV、260 mA 及120 kV、150 mA 2组,每组20例,其中80 kV 组为低浓度等渗对比剂(Visipaque 270 mg I/mL),50% ASiR;120 kV 组为高浓度对比剂(Ultravist 370 mg I/mL),滤波反投影(FBP)。比较2组中 BA 的 CT 值、图像噪声(SD)、信噪比(SNR)、对比噪声比(CNR)及有效辐射剂量(ED)。所得结果应用 SPSS 17.0软件采用独立样本 t 检验两两比较,P <0.05有统计学意义。结果80 kV 组的 CT 值(317.33 HU±70.44 HU)高于120 kV 组(256.39 HU±37.38 HU),差异有统计学意义(P <0.05);80 kV 组 SD、ED 及剂量长度乘积(DLP)[SD (7.55±1.51)HU;ED (1.74±0.14)mSv;DLP (124.94±9.9)mGy/cm]低于120 kV 组[SD (9.36±1.26)HU;ED (3.20±0.35)mSv;DLP (228.82±25.13)mGy/cm],差异有统计学意义(P<0.05);80 kV 组的 CNR 和 SNR(CNR 59.71±17.36;SNR 44.01±14.71)均优于120 kV 组(CNR 37.61±6.16;SNR 27.75±4.72),差异有统计学意义(P <0.05)。80 kV 组图像质量主观评分(3.73±0.66)略低于120 kV 组(3.81±0.59),但差异无统计学意义(t =-0.558,P >0.05)。结论对于 BMI 在正常范围内的患者,采用低浓度等渗对比剂联合80 kV 和 ASiR 技术行 BA CTA 检查,可在保证 BA 图像质量的同时显著降低有效辐射剂量47%,降低碘用量27%。  相似文献   

9.
目的 探讨64层CT自动管电流调节技术(ATCM)结合低电压在幼儿胸部低剂量扫描中的应用价值.方法 搜集行64层CT ATCM胸部扫描的幼儿(≤2岁)48例,其中A组(管电压100 kV)30例,B组(管电压80kV) 18例;并与既往采用固定管电流条件下的低剂量扫描数据进行对比分析,对照组C组(100 kV/60 mAs)30例;其余扫描参数一致.记录每次扫描的平均管电流(mAs)、CT容积剂量指数(CTDIvol)、剂量长度值(DLP),计算出有效剂量(ED)及剂量减低比值(DR),并比较3组的剂量及图像质量.结果 A组CTDIvol为(1.11±0.19)mGy,B组CTDIvol为(0.99 ±0.11)mGy,C组CTDIvol为(2.38±0.00) mGy;3组数据两两比较差异均有统计学意义(P<0.05).A组相对C组DR约51.07%,B组相对C组DR降低约58.20%.3组图像质量均满足诊断要求,差异无统计学意义(P=0.50).结论 低电压联合ATCM技术在幼儿胸部扫描中可以广泛应用,能够有效降低辐射剂量且不影响图像质量.  相似文献   

10.
目的探讨双源CT低kV和CARE Dose 4D管电流调节技术对降低主动脉CT血管成像(CTA)的辐射剂量的价值及其对图像质量的影响。资料与方法对临床拟诊主动脉夹层的53例患者行双源CT主动脉成像检查。并按数字表法将患者随机分为3组:A组:17例。扫描管电压为120 kV;B组:18例。扫描管电压为120 kV和CARE Dose 4D技术;C组:18例。扫描管电压为100 kV和CARE Dose 4D技术;3组其他扫描参数和重组参数均相同。测量气管分叉层面和肝门层面主动脉的CT强化值及图像噪声(SD),并由两名有经验的医师对3组图像质量进行评价。比较A组和B组、B组和C组平均容积CT剂量指数(CTDIvol),剂量长度乘积(DLP),有效剂量(ED),SD,信噪比(SNR),对比噪声比(CNR)和扫描长度。结果 A、B、C 3组图像质量评分依次为2.94±0.24、2.89±0.32、2.94±0.23。A、B、C 3组CTDIvol分别为(7.2±1.8)mGy、(6.1±1.4)mGy、(3.7±1.0)mGy;ED分别为(6.0±0.4)mSv、(5.0±1.0)mSv、(3.2±0.9)mSv;S...  相似文献   

11.
双源CT低管电压技术在超重患者冠状动脉成像中的应用   总被引:1,自引:1,他引:0  
目的 探讨在超重患者双源CT冠状动脉成像中低管电压技术的应用价值,评价其图像质量和辐射剂量.方法 将66例接受双源CT冠状动脉检查,体质量<85 kg、且体质量指数(BMI)为25.0~30.0 ks/m2的患者完全随机化分为A、B 2组.A组30例,管电压为120 kVp;B组36例,管电压为100 kVp.所有患者均采用回顾性心电门控螺旋扫描和四维智能在线剂量调控(CARE Dose 4D)技术,严格控制扫描范围.对2组的扫描数据分别进行多种图像后处理,由影像科副主任医师和副主任技师各1名采用双盲法评估图像质量.测量并计算信噪比(SNR)、对比信噪比(CNR).记录CT容积剂量指数(CTDIvol)和剂量长度乘积(DLP),计算有效辐射剂量(ED).应用两独立样本t检验比较2组患者图像ROI的CT值、噪声、SNR、CNR、辐射剂量及对比剂用量、图像质量评分等.应用X2检验比较两组患者冠状动脉图像质量分级显示段数.应用Kappa检验判断2名评价者评分的一致性.以P<0.05为差异有统计学意义.结果 图像ROI内CT值、噪声(以标准差SD计算)、SNR测量值:A组右冠状动脉(RCA)起始部分别为(429.3±77.4)HU,24.0±8.2、21.8±9.9,左冠状动脉主干(LMA)起始部分别为(436.7±79.0)HU、19.4±7.3、22.3±9.8;B组RCA分别为(503.5±95.4)HU、34.0±12.6、21.0±10.7,LMA分别为(491.7±96.2)HU、33.4±15.5、20.6±11.4;CNR测量值:A组为24.4±10.3,B组为21.9±8.2.2组患者冠状动脉血管腔内强化平均CT值、噪声比较,B组大于A组,差异有统汁学意义(P值均<0.05);2组间SNR、CNR筹异无统计学意义(P值均>0.05);2组CTDIvol比较,A组为(42.2±13.8)mGy,B组为(20.2±6.5)mGy,差异有统计学意义(P<0.05);A组ED为(9.5±3.6)roSy,B组为(4.8±1.7)mSv,差异有统汁学意义(P<0.05);A组图像质量评分为(4.5±1.0)分,B组为(4.7±0.5)分,筹异无统计学意义(P>0.05);A绀评价383段冠状动脉,图像优良者377段(98.4%)B组评价490段冠状动脉,图像优良者483段(98.6%).结论 对于BMI在25.0~30.0 kg/m2的患者,使用100 kVp管电压配合CARE Dose 4D技术进行双源CT冠状动脉检查,可以获得较好的图像质量,并且可以显著降低辐射剂量.
Abstract:
Objective To investigate the image quality and the radiation dose of dual-source computed tomography coronary angiography by using low kilovohage combination with low tube current in overweight patients.Methods Sixty-six patients with body mass inde,(BMI)25.(0-30.0 kg/m2 and a body weight<85 kg were randomized two groups(group A and group B).Thirty patients in group A were examined with 120 kVp,and 36 patients in group B with 100 kVp.ECG-pulsing and care dose 4D for radiation dose reduction were used in all patients.All images were transferred to Siemens workstation for post processing and analysis.Two observers blimted to clinical data independently assessed the image quality of each coronary segment by using a 5-point scoring scale(5:excellent,1:no diagnostic).and measured the different image parameters including image noise,signal-to-noise ratio(SNR)and contrast-to-noise ratio (CNR).The effective dose(ED)was calculated by using CT dose volume index(CTDIvol)and the doselength product (DLP). The mean intraluminal attenuation, image noise, SNR, CNR, radiation dose,volume of contrast medium, and mean image quality scores were compared between the two groups with t test. The grading quantity of coronary artery segment was compared with Chi-square test. The interobserver agreement was determined by Kappa statistics. Results The mean intraluminal attenuation, image noise,SNR in group A were (429. 3±77.4 ) HU, 24.0±8.2, 21.8±9. 9 in right coronary artery ( RCA), and (436. 7±79. 0) HU, 19.4±7.3, 22. 3±9. 8 in left main coronary artery (LMA ), and that in group B were (503.5±95.4) HU, 34.0±12.6, 21.0±10.7 in RCA, and (491.7±96.2) HU, 33.4±15.5,20.6±11.4 in LMA. The CNR were 24.4±10.3 in group A and 21.9±8.2 in group B. The mean intraluminal attenuation and image noise were significantly higher for group B compared with group A ( P <0. 05 ). There were no difference in SNR and CNR between the two groups ( P > 0. 05 ). Estimated ED in group B was significantly lower than that in group A [CTDIvol = (42. 2±13. 8) mGy, ED = (9. 5±3.6)mSv in group A vs. CTDIvol = ( 20. 2±6.5 ) mGy, ED = (4. 8±1.7 ) mSv in group B ; each P < 0. 05 ].Mean image quality scores were not significantly different between two groups ( 4. 5±1.0 in group A vs.4. 7±0. 5 in group B, P > 0. 05 ). A total of 383 coronary artery segments were evaluated in group A and 490 segments in group B. The difference of grading quantity of coronary artery segment was no statistical significant between two groups. Conclusions 100 kVp combination with ECC-pulsing and CARE Dose 4D of dual-source CTCA was valuable for patients with BMI ranging from 25 to 30 kg/m2 which have a better image quality and low radiatiun dose.  相似文献   

12.
目的 研究新双源CT的虚拟平扫技术在肝脏扫描中的应用价值.方法 51例肝脏CT平扫和增强扫描患者在完成常规平扫、肝动脉期及门静脉期3期扫描后,采用肝脏虚拟平扫后处理软件生成虚拟平扫图像.采用Wilcoxon分析比较常规平扫和虚拟平扫图像的病灶显示,并利用t检验对比分析肝脏、肌肉的CT值、图像SNR,以及患者单期扫描时接受的辐射剂量和总辐射剂量容积CT剂量指数(CTDIvol)值和剂量长度乘积(DLP)值.结果 虚拟平扫和常规平扫在病灶显示上无明显差异.虚拟平扫肝脏CT值(61.32±6.04)HU,大于常规平扫的(56.85±4.80)HU,差异有统计学意义(t=-3.927,P<0.01);虚拟平扫图像SNR 11.28±2.78,大于常规平扫的8.65±1.56,差异有统计学意义(t=-5.590,P<0.01).虚拟平扫CTDIvol总量(14.35±1.66)mGy和DLP总量(313.91±45.08)mGy·cm均低于常规平扫的(21.43±2.46)mGy和(469.02±66.22)mGy·cm,差异均有统计学意义(t值分别为16.168和13.132,P值均<0.01).结论 新双源CT的虚拟平扫技术在保证图像质量的前提下降低了辐射剂量,使其取代常规平扫成为可能.
Abstract:
Objective To assess the virtual non-contrast liver CT from dual-energy CT for the clinical application. Methods In total, 51 patients were included in the study, and all patients underwent multi-phase liver CT on a dual-source CT. The True non-contrast liver CT (TNCT) was performed in a single-energy acquisition mode, but the arterial and portovenous liver CT (VNCT) were performed in a dual-energy mode of 110 kV and 140 kV respectively. The virtual non-contrast CT images were derived from the arterial data using liver virtual non-contrast software. Between the true non-contrast CT and the virtual non-contrast CT, the image quality, mean CT HU values in the liver and muscle, signal to noise (SNR), the radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination were compared with t test. Results There was no significant difference in the detection of liver lesions between TNCT and VNCT. The CT Hu values of muscle on both TNCT and VNCT images were almost equal. The CT HU values of liver on VNCT images were higher than that on TNCT images and the difference was significant [61.32 ±6. 04 vs. (56. 85 ±4. 80) HU, t = -3. 927,P<0.01]. There was also significant differenc of SNR between TNCT (11.28±2. 78) and VNCT (8.65 ± 1.56) images( t =-5.590,P<0.01). The CTDIvol and DLP of single phase were (7.07 ±0.85) mGy and (155.11 ±respectively, but in TNCT the total CTDIvol and DLP reached (21.43 ± 2. 46 ) mGy and (469. 02 ±significance, but the total CTDIvol and DLP were significantly different (t = 16. 168 and 13. 132, P <0. 01). Conclusion With the consequent reduction in radiation dose, the VNCT can replace TNCT as an imaging protocol in multi-phase abdominal CT examination in clinic.  相似文献   

13.
目的 比较第一代与Flash双源CT不同扫描方式在肺动脉成像时剂量与图像质量.方法 收集120例临床疑诊为PE患者,按扫描方式随机分为4组:A组行第一代双源CT双能量扫描(80/140kV),B组行flash双源CT双能量扫描(80/sn140kV),C组行flash双源CT双能量扫描(100/sn140kV),D组行flash双源CT双能量扫描(140/80kV).比较4组间的CT容积剂量指数(CT dose volume index,CTDIvol)、剂量长度乘积(dose length product,DLP)、背景噪声和肺动脉信噪比.结果 各组间患者一般情况没有明显统计学差异.B组的CTDIvol,DLP值明显低于A、C两组,图像质量明显好于D组.结论 flash双源CT(80/sn140kV)在获得满意的图像质量的同时可以减低辐射剂量.  相似文献   

14.
目的探讨64排螺旋CT(MSCT),采用固定噪声指数(NI)的Z轴自动管电流调节(ATCM)技术在主动脉夹层术后CT造影中对图像质量及辐射剂量的影响。资料与方法随机将本院主动脉夹层术后的患者100例分为2组,每组50例。A组采用固定管电流扫描技术,均采用280 mA。B组采用Z轴ATCM扫描技术,管电流为100~350 mA,根据体重指数(BMI)不同分为两组:BMI>25 kg/m2者,NI=10;BMI<25 kg/m2者,NI=12,其余扫描参数均一致。将所有图像均传输至ADW 4.3工作站,进行三维及二维后处理,同时记录机器自动生成的CT剂量指数(CTDlvol)、相应剂量长度乘积(DLP)。结果 B组在不影响诊断的情况下,辐射剂量较A组CTDlvol降低了28.3%、DLP降低了30.4%。A组CTDIvol均值为(19.13±1.94)mGy;DLP均值为(1205.59±197.12)mGy.cm,B组BMI>25 kg/m2者CTDIvol均值为(14.82±2.97)mGy;DLP均值为(887.6±177.51)mGy.cm,BMI<25kg/m2者CTDIvol均值为(12.61±2.17)mGy;DLP均值为(789.86±139.33)mGy.cm,所有图像均能满足诊断需要。结论 64排螺旋CT采用固定NI的ATCM技术在主动脉夹层CT造影中可获得较好图像质量,在满足诊断需求的同时降低了患者辐射剂量。  相似文献   

15.
目的 探讨自动管电流调制(ATCM)技术对PET/CT受检者CT图像质量及有效剂量的影响。 方法 将2017年10月至2018年7月接受PET/CT检查的90例受检者按系统抽样方法分为A、B、C 3组,每组各30例。CT采用ATCM扫描。A、B两组采用的管电流区间为60~240 mA,噪声指数分别为10、15;C组管电流区间为60~180 mA,噪声指数为15。记录容积CT剂量指数(CTDIvol)和剂量长度乘积(DLP),根据公式估算有效剂量。由两位核医学科主治及以上医师采用双盲法对受检者颈部、胸部、腹部、盆腔CT图像质量进行评分,测定图像CT值、噪声值并计算信噪比。采用方差分析比较3组的噪声值、信噪比差异,采用非参数检验中的Kruskal-Wallis检验比较3组的CTDIvol、DLP、有效剂量差异,组内两两比较采用Nemenyi检验。 结果 A、B、C 3组受检者所有图像质量评分均不低于3分,且差异均有统计学意义(F=3.77~14.42,均P<0.05)。A、B、C 3组受检者的噪声值[(11.90±2.83)~(26.03±3.74)]、信噪比[(2.03±0.34)~(4.35±0.71)]差异均有统计学意义(F=38.01~64.20和F=32.09~81.62,均P<0.05),CT图像质量均能满足临床诊断要求。A、B、C 3组受检者的CTDIvol[(12.44±0.53)、(9.39±2.01)和(7.05±1.03)mGy]、DLP[(998.45±96.04)、(741.60±168.87)和(571.29±97.41) mGy·cm]、有效剂量[(14.98±1.44)、(11.12±2.53)和(8.57±1.46) mSv]的差异均有统计学意义(χ2=62.18、57.19和57.16,均P<0.05)。其中,C组比A组的有效剂量低,差异有统计学意义(χ2=56.55,P<0.05)。 结论 应用PET/CT ATCM技术,合理调节管电流区间及噪声指数,保证图像质量的同时可有效降低受检者的有效剂量。   相似文献   

16.
目的:探讨CARE技术即自动综合选择管电压(CAREkV)和四维实时剂量调节CAREDose4D技术对冠脉CTA辐射剂量和图像质量的影响。方法将78例患者随机分成两组,采用西门子64排128层DefinitionAS螺旋CT机行回顾性心电门控螺旋扫描。A组41例,由CAREkV选择输出管电压;B组37例,管电压人为设定120kVp。两组均采用CAREDose4D技术,其他扫描参数两组相同。应用t检验比较两组CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)、图像质量评分、信噪比(SNR)和对比噪声比(CNR),P<0.05认为有统计学差异。结果A和B两组CTDIvol分别为(17.15±10.87)mGy和(29.97±7.80)mGy;DLP分别为(261.43±176.49)mGy×cm和(469.61±119.66)mGy×cm;ED分别为(3.62±2.98)mSv和(6.58±2.03)mSv,两组间CTDIvol、DLP和ED值差异有统计学意义(P<0.05),且A组ED降低44.98%。A和B两组图像质量评分分别为(3.58±0.27)和(3.63±0.31),差异无统计学意义(P>0.05);主动脉根部管腔的SNR分别为(18.14±4.27)和(17.96±3.37),差异无统计学意义(P>0.05);A组RCA和LM近端管腔的CNR分别为(23.07±8.89)和(27.26±9.57),B组分别为(17.23±7.35)和(21.27±8.43),差异有统计学意义(P<0.05),A组CNR大于B组。结论应用于冠状动脉造影的CARE技术,在保证图像质量的同时,可降低受检者44.98%的有效辐射剂量,具有临床意义。  相似文献   

17.
目的 探讨64层螺旋CT自动毫安技术(ATCM)对降低下肢动脉血管成像辐射剂量的可行性。方法 通过预实验改变噪声指数(NI)调节管电流,得出NI值为10 HU时图像质量与辐射剂量匹配较佳。搜集52例疑有下肢动脉闭塞糖尿病及高血压病患者病例,随机分为实验组和对照组行自肾下腹主动脉至足底的CT容积扫描,每组病例26例。对照组采用常规固定300 mA(FM组),实验组采用NI为10 HU的自动毫安(ATCM组)技术。分别选择肾下腹主动脉、髋关节水平股动脉、 NFDB1 动脉及踝关节胫前动脉平面作为观察平面,对两种毫安技术的图像质量、图像噪声和辐射剂量均采用 t 检验方法进行统计学分析。结果 FM组的辐射剂量CTDIvol为10.81 mGy,平均DLP为(1280.4±124.7)mGy·cm,ATCM组的平均CTDIvol为(5.14±1.23)mGy,平均DLP为(582.86±150.41)mGy·cm,比FM组降低约54.4%,两组差异有统计学意义(CTDIvol、DLP的 t 值分别为13.13、17.36, P 值均<0.05)。FM组的4个选取平面图像噪声分别为13.8±4.04、14.53±2.79、5.69±1.38、(4.75±1.38) HU。ATCM组分别为10.76±2.11、12.13±2.96、10.47±2.96、(6.17±1.53) HU,两组差异有统计学意义( t 值分别为2.911、3.038、7.287及3.186, P 值均<0.05),ATCM组肾下腹主动脉、髋关节水平股动脉层面的图像噪声较FM组的低,而 NFDB1 动脉、踝关节胫前动脉层面的图像噪声较FM组的高,ATCM组图像噪声变异度小,图像更加均匀。FM组图像质量评分平均为2.654±0.562,ATCM组图像评分平均为2.462±0.582,两组图像质量评分差异无统计学意义( t =1.21, P >0.05)。结论 使用噪声指数为10的下肢动脉ATCM技术,在保证图像质量的情况下可以降低辐射剂量约54.4%。  相似文献   

18.
齐燕  欧陕兴  钱民  彭光明  刘波  刘玉品   《放射学实践》2012,27(10):1095-1099
目的:探讨运用双源CT双能量技术行冠状动脉血管成像的图像质量和辐射剂量。方法:204例患者分为两组行双源CT冠状动脉血管造影检查,A组采用双能量扫描方案,B组采用传统单能量扫描方案,比较两组的图像质量及辐射剂量。结果:A、B两组冠状动脉图像质量评分分别为(4.70±0.72)分、(4.70±0.71)分,两组间差异无统计学意义(t=-1.000,P=0.318)。A、B两组图像左、右冠状动脉信噪比(SNR)分别为A组20.0±3.4和19.0±3.0、B组20.1±3.2和19.9±3.2,且两组间差异均无统计学意义(t=1.967,P=0.051;t=-0.233,P=0.816)。A、B两组的容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)分别为(48.27±8.70)mGy、(54.10±8.77)mGy;(565.63±115.48)mGy.cm、(702.75±144.04)mGy.cm;(9.62±1.96)mSv、(11.95±2.45)mSv,A组的CTDIvol、DLP及ED明显低于B组,差异均有统计学意义(t=-4.764,P=0.000;t=-7.501,P=0.000;t=-7.501,P=0.000)。结论:双能量心肌灌注成像技术在不降低图像质量的情况下,能够显著降低患者的有效辐射剂量,有很高的临床应用价值。  相似文献   