首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   51篇
  免费   4篇
工业技术   55篇
  2023年   1篇
  2021年   1篇
  2018年   1篇
  2016年   4篇
  2015年   2篇
  2013年   3篇
  2012年   2篇
  2011年   1篇
  2009年   2篇
  2008年   1篇
  2007年   2篇
  2006年   1篇
  2005年   1篇
  2004年   2篇
  2003年   5篇
  2002年   3篇
  2001年   1篇
  2000年   1篇
  1999年   2篇
  1998年   4篇
  1997年   1篇
  1996年   3篇
  1995年   1篇
  1994年   5篇
  1993年   2篇
  1992年   1篇
  1989年   1篇
  1988年   1篇
排序方式: 共有55条查询结果,搜索用时 62 毫秒
1.
The emissions of volatile organic compounds (VOCs) from building materials may significantly contribute to indoor air pollution, and VOCs have been associated with odor annoyance and adverse health effects. Wood materials together with coatings are commonly used indoors for furniture and large surfaces such as walls, floors, and ceilings. This leads to high surface-to-volume ratios, and therefore, these materials may participate remarkably to the VOC levels of indoor environment. We studied emissions of VOCs and carbonyl compounds from pinewood (Pinus sylvestris) boards of 10% and 16% moisture contents (MC) with three paints using small-scale test chambers (27 L). The emissions from uncoated pinewood and paints (on a glass substrate) were tested as references. The 28-day experiment showed that the VOC emissions from uncoated pinewood were lower from sample with 16% MC. Painted pinewood samples showed lower emissions compared to paints on glass substrate. Additionally, paints on 16% MC pinewood exhibited lower emissions than on drier 10% MC wood. The emissions from painted pinewood samples were dominated by paint-based compounds, but the share of wood-based compounds increased over time. However, we noticed differences between the paints, and wood-based emissions were clearly higher with the most permeable paint.  相似文献   
2.
The relevance of particle mass, surface area or number concentration as risk indicators for health effects in non-industrial buildings has been assessed by a European interdisciplinary group of researchers (called EUROPART) by reviewing papers identified in Medline, Toxline, and OSH. Studies dealing with dermal effects or cancer or specifically addressing environmental tobacco smoke, house dust-mite, cockroach or animal allergens, microorganisms and pesticides were excluded. A total of 70 papers were reviewed, and eight were identified for the final review: Five experimental studies involving mainly healthy subjects, two cross-sectional office studies and one longitudinal study among elderly on cardiovascular effects. From most studies, no definite conclusions could be drawn. Overall, the group concluded that there is inadequate scientific evidence that airborne, indoor particulate mass or number concentrations can be used as generally applicable risk indicators of health effects in non-industrial buildings and consequently that there is inadequate scientific evidence for establishing limit values or guidelines for particulate mass or number concentrations.  相似文献   
3.
Abstract Fungal spore content in dust accumulated in air ducts was investigated in 24 mechanically ventilated single-family houses of which 15 had also a central air heating system. Dust was collected from the ducts simultaneously with cleaning of the ventilation systems. Besides spore concentrations and flora of culturable fungi, total fungal spore concentrations were determined in dust samples by the aqueous two-phase technique and spore counting with epifluorescence microscopy. Culturable spore concentrations in the dust varied from 104 to 107 CFU/g and total spore concentrations from 107 to 108 spores/g. Total spore concentrations in the duct dust were significantly higher in the air heated houses than in the other mechanically ventilated houses. The difference resulted mainly from a higher proportion of recirculation air and a higher age of the air heated houses. Cladosporium, Penicillium, Aspergillus and yeasts consisted of >90% of fungal flora in the dust. Although total spore concentrations were at the same level both in the exhaust and in the supply ducts in both types of house, culturable fungal spore concentrations were slightly higher in the exhaust ducts than in the supply ducts. The proportion of culturable spores was <5% of total spores in dust accumulated in the ducts.  相似文献   
4.
The actor-partner interdependence model was used to test whether one parent's depressive vulnerability (self-criticism and dependency) was associated with the same parent's own (an intraparental association) and the other parent's (a cross-parental association) ratings of their 5-year-old child's temperament (536 parents, 268 dyads). The more vulnerable the parents were, the more the children showed negative affectivity and lack of effortful control. Significant interactions with the parent's gender and between the spouses' depressive vulnerabilities were found, highlighting the fact that child outcomes are dependent on family processes. All associations were independent of maternal and paternal depressive symptoms. The influence of personality-based depressive traits on child temperamental outcomes and effective parenting is discussed with reference to between-dyad family dynamics. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   
5.
The triboelectric charging of fungal spores was experimentally characterized during rebound and resuspension. A fungal spore source strength tester (FSSST) was used as a primary aerosol generator for spores of three fungal species and two powders (silicon carbide and silver). The critical velocity of rebound was determined using a variable nozzle area impactor (VNAI), and the charging state of particles after resuspension and rebound was measured using the FSSST, different impactor setups, electrometers, and optical particle counters. In the impactor setups and the FSSST, five different surface materials relevant for indoor environments were used (steel, glass, polystyrene, paper, and polytetrafluoroethylene). The critical velocity of rebound was determined to be 0.57 m/s for fungal spores, which is relatively low compared to silicon carbide and previous results for micron-sized aerosol particles. Based on the rebound impactor measurements, we were able to define the crucial parameters of charge transfer for different particle–surface material pairs. A contact charge parameter, which describes the triboelectric charging during rebound, was found to have a negative correlation with the charging state of the particles after the resuspension from an impactor. This connects the triboelectric charging during rebound and resuspension to each other. Based on the contact charge parameter values, quantified triboelectric series could be formed. The results of this work show that fungal spores can be charged both positively and negatively during rebound and resuspension depending on the fungal species and surface material.

Copyright © 2016 American Association for Aerosol Research  相似文献   

6.
The development of odor emission rates from EU6 classified glass fiber bag filters was studied in four air-handling units (AHU), and emissions from the same kind of filters with EU3 classified polyester prefilters were studied in two units. The filters were loaded in six AHU in downtown Helsinki. The pressure drop was measured, and the odors of the filters were evaluated by a trained panel under laboratory conditions (T = 20°C, face velocity 1.0 m/s) every sixth week. The odor emissions of simultaneous atmospheric dust samples were also studied. The odor emissions of the filters rose during the first three months to a level where every third person would be dissatisfied. The emissions from coarse prefilters were similar to those from the more efficient filters without prefilters, and the emissions of the main filters were significantly lower if used with prefilters. This result indicates that the prefilters effectively protected the fine filters from odor-causing particles. The results of tests made with atmospheric samples agree with this result. Relative odor emissions were the highest in coarse fractions (> 10.0 μm). The pressure drop increased with the particle mass collected on the ventilation filter, but it did not correlate well with the odor emission of the filter. Thus, pressure drop alone is not an adequate criterion for changing supply air filters when hygienic aspects are a concern.  相似文献   
7.
In a subarctic climate the diurnal variation in temperature may cause water condensation in ducts placed in the unheated spaces of a building. In this study, germination time and sporulation of a fungus, Penicillium verrucosum , were studied on dusty, galvanized steel sheet under different moisture conditions at room temperature. The effect of condensed water in a supply air duct on spore amplification was studied in an experimental ventilation set-up. In the field, air temperatures and the dew point temperature of air in the duct were monitored continuously for a week. P. verrucosum germinated on steel surfaces during five-hour incubation of the surface under humid conditions; when the surface had been moist for half an hour, germ tubes appeared within 17 hours. During 24-hour incubation under moist conditions, P. verrucosum produced hypae and spores. In the experimental set-up the airborne spore counts increased when the air passed through a water-condensingsection of the duct. Penicillium was the most abundant fungus sporulated on the moist duct surface. In the field, during humid weather, the surface temperature on the air stream surface decreased to the dew point temperature of the air in the duct. Thus water condensation in air ducts may promote fungal growth.  相似文献   
8.
Three enzymatic activities of the CYP2A subfamily, coumarin 7-hydroxylase (COH), testosterone 15 alpha-hydroxylase (T15 alpha OH) and testosterone 7 alpha-hydroxylase (T7 alpha OH), were characterized in liver, kidney and lung microsomes from control, pyrazole (PYR), 3-methylcholanthrene (MC) and phenobarbital (PB) treated female and male Syrian golden hamsters. Sex-dependent changes in the enzymatic activities were found. Among control animals COH and T15 alpha OH activities were higher in males. T7 alpha OH activity was five times higher in female kidneys than in males. Inducers changed this metabolic profile. MC and PB were potent CYP2A inducers in extrahepatic tissues: significant increases were found in COH (5-fold) and T15 alpha OH (12-fold) activities in female MC lung microsomes and T7 alpha OH (7-fold) in MC male kidney microsomes. PB increased significantly activities of COH (5-fold), T15 alpha OH (3-fold) and T7 alpha OH (10-fold) in male kidney microsomes. All inducers significantly increased T7 alpha OH activity in male kidney microsomes but decreased hepatic T7 alpha OH activity in both sexes. PYR treatment decreased hepatic CYP2A activities. Anti-mouse CYP2A4/5 antibody inhibited COH activity by a variable extent depending on the tissue and pretreatment and recognised three 52-, 49-, 48-kDa bands in liver and two major bands in kidney (48 and 49 kDa) and lung (49 and 52 kDa) microsomes. COH and T15 alpha OH activities correlated well with 49 kDa protein (r = 0.95 and r = 0.99, respectively) in lung microsomes.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   
9.
10.
The aim of this study was to evaluate the amount of dust in supply air ducts in recently installed ventilation systems. The samples for the determination of dust accumulation were collected from supply air ducts in 18 new buildings that have been constructed according to two different cleanliness control levels classified as category P1 (low oil residues and protected against contaminations) and category P2, as defined in the Classification of Indoor Climate, Construction and Building Materials. In the ducts installed according to the requirements of cleanliness category P1 the mean amount of accumulated dust was 0.9 g/m2 (0.4-2.9 g/m2), and in the ducts installed according to the cleanliness category P2 it was 2.3 g/m2 (1.2-4.9 g/m2). A significant difference was found in the mean amounts of dust between ducts of categories P1 and P2 (P < 0.008). The cleanliness control procedure in category P1 proved to be a useful and effective tool for preventing dust accumulation in new air ducts during the construction process. Additionally, the ducts without residual oil had lower amounts of accumulated dust indicating that the demand for oil free components in the cleanliness classification is reasonable.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号