首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Principles of CT: multislice CT   总被引:1,自引:0,他引:1  
This article describes the principles and evolution of multislice CT (MSCT), including conceptual differences associated with slice definition, cone beam effects, helical pitch, and helical scan technique. MSCT radiation dosimetry is described, and dose issues associated with MSCT-and with CT in general-as well as techniques for reducing patient radiation dose are discussed. Factors associated with the large volume of data associated with MSCT examinations are presented.  相似文献   

2.
Principles of CT and CT technology   总被引:1,自引:0,他引:1  
This article provides a review of the basic principles of CT within the context of the evolution of CT. Modern CT technology can be understood as a natural progression of improvements and innovations in response to both engineering problems and clinical requirements. Detailed discussions of multislice CT, CT image quality evaluation, and radiation doses in CT will be presented in upcoming articles in this series.  相似文献   

3.
Real-time CT and CT fluoroscopy.   总被引:2,自引:0,他引:2  
  相似文献   

4.

Purpose  

The aim of this study was to evaluate the diagnostic value of contrast-enhanced CT (CECT) versus non-enhanced low-dose CT (NECT) in the staging of advanced malignant melanoma with 18F-fluordeoxyglucose (FDG) positron emission tomography (PET)/CT.  相似文献   

5.
CT扫描参数对人体组织CT值影响的研究   总被引:6,自引:1,他引:5       下载免费PDF全文
目的 探索不同CT扫描参数对人体同一种组织CT值的影响。方法 通过在同一台CT机上,分别改变其中1个扫描参数,如X线管电压、毫安秒和重建函数等,而保持其他扫描参数不变,多次扫描标准体模,测量和分析体模中不同物质的CT值。结果 X线管电压的改变对物质的CT值影响具有显著意义。聚乙烯、聚碳酸酯、有机玻璃的CT值与管电压成正相关;聚四氟乙烯的CT值与管电压成负相关。毫安秒和重建函数对CT值的影响差异无统计学意义。结论 同一个人体组织在不同的X线管电压条件下CT值是变化的。因此,在临床影像诊断和放疗中应该考虑图像扫描参数的设置对诊断和治疗结果的影响。  相似文献   

6.
CT angiography   总被引:13,自引:0,他引:13  
The advent of spiral (helical, volume ) CT has revolutionised the performance of body CT and allowed the development of CT angiography (CTA). CT angiography is a non-invasive method of visualising the vascular system and in some instances can replace conventional angiography. In spiral CT a volume of data is obtained rapidly with no respiratory misregistration at peak vascular opacification following the peripheral injection of contrast. Appropriate timing will ensure that either the venous or arterial tree is visualised and from the volume of data multiple overlapping slices can be obtained to generate 2D and 3D images with no increase in radiation to the patient. CT angiography may be performed as a dedicated study or be undertaken retrospectively using post-processing of data from a conventional diagnostic spiral scan to provide additional information about the vascular tree. When undertaken as a dedicated study CTA is quicker, less invasive and less costly than a conventional angiogram with a decrease in the radiation dose to the patient; however, the spatial resolution is limited with vessels less than 2 mm not visualised and there is no contrast saving. Received: 25 March 1998; Revision received: 16 July 1998; Accepted: 22 July 1998  相似文献   

7.
Cardiac CT     
  相似文献   

8.
9.
Limitations of CT during PET/CT.   总被引:1,自引:0,他引:1  
Our aim was to determine the diagnostic limitations of low-dose, unenhanced CT scans performed for anatomic reference and attenuation correction during PET/CT. METHODS: The Radiology Information System at our oncologic hospital was queried during the 9-mo period from July 2002 to April 2003 for patients with PET/CT scans and diagnostic enhanced CT within 2 wk of each other. One radiologist interpreted the CT portion of the PET/CT (CT(p)) unaware of the PET results and the associated enhanced diagnostic CT (CT(d)). A medical student compared this interpretation with the official report of the CT(d) and listed all discrepancies between reports. A separate radiologist compared CT(p) and CT(d) images and classified true discrepant findings as due to lack of intravenous contrast, arm-position artifact, lack of enteric contrast, low milliamperage (mA), and quality of lung images. RESULTS: Among 100 patients, the most common malignancies were lymphoma (n = 37), cancer of the colorectum (n = 31), and esophageal cancer (n = 15). Among 194 true discrepancies in which findings were missed at CT(p), causes were as follows: (a) lack of intravenous contrast (128/194, 66%), (b) arm-down artifact (17/194, 9%), (c) quality of lung images (26/194, 13%), (d) lack of enteric contrast (15/194, 8%), and (e) low mA (8/194, 4%). Discrepancies were seen most commonly in detecting lymphadenopathy and visceral metastases. CONCLUSION: Most missed findings on the unenhanced CT portion of the PET/CT scans were due to technical factors that could be altered. Discrepant findings would have led to altered management in only 2 patients, suggesting a role for limited repeat imaging to reduce radiation and use of valuable resources.  相似文献   

10.

Purpose

To evaluate the role of 64-multidetector CT in assessment of mesenteric vascular ischemia in clinically suspected patients.

Patients and methods

This study included 38 patients during period from October 2009 to October 2011. The patients age ranged from 38 to 72 year old (mean age was 57 ± 11.2 years). All cases met the criteria of acute non traumatic (28 patients) or chronic abdominal pain (10 patients) and suspected mesenteric vascular ischemia. All 38 cases were evaluated in surgery department, then underwent CT of the abdomen and pelvis & CTA by using 64 multislice GE light speed VCT. MDCT& CT angiographic findings were correlated with surgical findings in acute mesenteric ischemia (AMI) cases & conventional angiography in chronic mesenteric ischemia (CMI) cases.

Results

MDCT findings alone were nonspecific for detection of MI. The sensitivity, specificity& accuracy of CTA in diagnosis of AMI after surgical confirmation were 96%, 66.6% & 92.8% respectively, while in CMI the sensitivity, specificity & accuracy were 88.8%, 100%, 90% respectively, after confirmation by conventional angiography.

Conclusion

CTA scan appears to be an excellent tool to find out and localize cases of AMI rather than in CMI cases.  相似文献   

11.
CT urography     
With the advent of multi-detector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract-the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mm in diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination—MDCTU.  相似文献   

12.
13.
CT urography     
With the advent of multi-detector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract-the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mm in diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination--MDCTU.  相似文献   

14.
15.
16.
CT Enteroclysis     
Computed tomographic (CT) enteroclysis is a hybrid technique that combines the methods of fluoroscopic intubation-infusion small-bowel examinations with that of abdominal CT. The use of multidetector CT technology has made this a versatile examination that has evolved into two distinct technical modifications. CT enteroclysis can be performed by using positive enteral contrast material without intravenous contrast material and neutral enteral contrast material with intravenous contrast material. CT enteroclysis has been shown to be superior to other imaging tests such as peroral small-bowel examinations, conventional CT, and barium enteroclysis, except in the demonstration of early apthous ulcers of Crohn disease. CT enteroclysis is complementary to capsule endoscopy in the elective investigation of small-bowel disease, with a specific role in the investigation of Crohn disease, small-bowel obstruction, and unexplained gastrointestinal bleeding.  相似文献   

17.
CT screening     
Amis ES 《Radiology》2003,228(3):901-902
  相似文献   

18.
CT fluoroscopy   总被引:1,自引:0,他引:1  
Rogalla P  Juran R 《Der Radiologe》2004,44(7):671-675
Percutaneous biopsy of pulmonary nodules requires precise needle placement, with the goal of attaining a secure position of the needle for therapeutic or diagnostic purposes as quickly as possible and with minimal tissue damage along the access route. The requirements from the image guidance system during the intervention are, in addition to universal applicability, a quick reaction time and a user-friendly interface. CT fluoroscopy fulfils these requirements, although radiation protection for the patient and radiologist becomes an important issue.  相似文献   

19.
PURPOSE: To measure the effective radiation doses delivered at electron-beam computed tomography (CT) and multi-detector row spiral CT of coronary arteries and to compare these doses with those delivered at catheter coronary angiography. MATERIALS AND METHODS: An anthropomorphic phantom equipped with 66 thermoluminescent dosimeters was imaged at cardiac CT. Four protocols for unenhanced coronary artery calcium scoring were simulated: one with electron-beam CT and three with multi-detector row CT. Four similar protocols for coronary CT angiography were simulated. All multi-detector row spiral CT protocols were performed with retrospective electrocardiographic triggering. Biplane catheter coronary angiography also was simulated. Radiation doses to organs were measured, and effective doses were calculated according to guidelines published in International Commission on Radiological Protection Publication 60. RESULTS: Coronary artery calcium scoring with electron-beam CT yielded effective radiation doses of 1.0 and 1.3 mSv for male and female patients, respectively. The radiation doses at calcium scoring with multi-detector row CT were 1.5-5.2 mSv for male patients and 1.8-6.2 mSv for female patients. Electron-beam CT coronary angiography yielded effective doses of 1.5 and 2.0 mSv for male and female patients, respectively. The highest effective doses were delivered at multi-detector row CT angiography: 6.7-10.9 mSv for male patients and 8.1-13.0 mSv for female patients. Catheter coronary angiography yielded effective doses of 2.1 and 2.5 mSv for male and female patients, respectively. CONCLUSION: Higher radiation doses are delivered at multi-detector row cardiac CT compared with the doses delivered at electron-beam CT and catheter coronary angiography.  相似文献   

20.
Multiphase hepatic CT with a multirow detector CT scanner   总被引:14,自引:0,他引:14  
OBJECTIVE: The aim of this study was to evaluate a new injection-acquisition technique performed using a multirow detector CT scanner for separation of three distinct hepatic circulatory phases (hepatic artery, portal venous inflow, hepatic venous) and to determine which of these phases is optimal for detecting hypervascular neoplasm. MATERIALS AND METHODS: Two sequential acquisitions were performed during a single breath-hold followed by a third acquisition beginning 60 sec after injection. Injection-to-scan delay for the first acquisition was the individual patient's circulation time, which was determined by a preliminary mini bolus. The mean attenuation of the upper abdominal aorta, portal vein, and hepatic parenchyma were determined for each imaging pass in 20 patients with cirrhosis and 20 patients without cirrhosis. Tumor-to-liver contrast for hypervascular primary and metastatic neoplasm was evaluated in a different set of 16 cirrhotic patients and nine noncirrhotic patients. Three-dimensional CT arteriograms were obtained from first-pass data. RESULTS: Three distinct circulatory phases (hepatic artery, portal vein inflow or late arterial, and hepatic venous) were seen in cirrhotic and noncirrhotic patients. Maximum tumor-to-liver contrast for hypervascular primary and metastatic neoplasm occurred during the second pass for both cirrhotic (p < 0.006) and noncirrhotic (p < 0. 001) patients. A three-dimensional hepatic-mesenteric CT arteriogram of normal or anomalous hepatic vessels without venous overlay was obtained from first-pass data in all patients. CONCLUSION: Rapid-sequence hepatic helical CT allows selection of the optimal time interval for hypervascular tumor detection. A new paradigm for rapid hepatic CT acquisition-namely, hepatic arterial, portal vein inflow, and hepatic venous phases-is recommended to replace hepatic artery dominant and portal venous phases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏