首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 171 毫秒
1.
李继东 《质谱学报》2008,29(Z1):64-64
A method for the determination of trace arsenic in high purity cobalt with hydride generation-ICP-MS was reported. Due to the interference of the oxide complex ions 59Co16O, the background concentration of 75As is about 100 µg•L-1 in 1 g•L-1 cobalt solution, which lead to the impossibility of the direct analysis for the trace As in high purity cobalt. However, the As background concentration can be decreased to several µg•L-1 if the simple HG system was applied and the 0.05 µg•g-1 of determination limits can obtained with this method.  相似文献   

2.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multiresidue method for the simultaneous determination of 10 anabolic steroids (ASs) in whole milk were developed. Milk samples were extracted with methanol and the samples were then subjected to a clean-up procedure using liquid-liquid extraction (LLE) methods. The samples were analysed by LC/MS/MS. The limits of detection (LOD) of LC/MS/MS method used for testing the 10 ASs in whole milk ranged from 0.06 to 0.22 µg•L-1, and the limits of quantification (LOQ) were from 0.12 to 0.54 µg•L-1. Experiments on spiked samples of whole milk showed that at addition levels of 1.0, 2.0, 10 µg•L-1 the average recoveries of the ASs were 24% to 86%, 25% to 91%, 31% to 71%, with relative standard deviations (RSDs) ranged from 12% to 37%, 5% to 20%, 10% to 16%, respectively.  相似文献   

3.
权伍英  王璟  迂君  张玉黔 《质谱学报》2008,29(Z1):173-174
Fumonisin B1 in maize was determined by liquid chromatography/tandem mass spectrometry. The analysis was extracted from maize samples by acetonitrile-water-acetic acid 49:50:1(V/V/V). Raw extracts were evaporated to dryness and dissolved with mobile phase, chromatographyed on a C18 column, and detection was performed on a triple quadrupole tandem mass spectrometry with electrospray ionization source. The method has a limit of quantification of 10 µg•kg-1 in maize samples. The calibration curve is linear in the range of 1-500 µg•L-1. The mean recovery ranges from 94 % to 104 %, and the relative standard derivations are lower than 9%. The method is sensitive and specific to be applied for determination of fumonisin B1 in maize samples.  相似文献   

4.
王绘军  王俊伟  张松 《质谱学报》2009,30(Z1):124-125
The method for extraction and determination of tramadol was established by HPLC-MS/MS. Calibration curves are linear on injection of amounts range of 50-1 000 μg•L-1. The limit of detection is 10 μg•L-1, and the recovery is above 80% for Tramadol.  相似文献   

5.
The aflatoxin B1, B2, G1, G2 in peanut were develop by LC-MS/MS. The mass spectrometer was operated in the positive ion mode using multiple reaction monitoring. The sample was extracted with methanol, and chromatographic separation was carried out on a MGIII-C18 column(2.1 mm×150 mm×1.8 μm) with eluthic sion of V(acetonitrile):V(water)=35:65. The limit of detection is 0.5 μg•L-1, the limit of quantitation is 0.5 μg•kg-1. The linear plots are between 0.5 μg•L-1 and 25.0 μg•L-1. Overall recoveries are between 88.3% and 99.2%, and RSD values are between 1.73% and 3.75%.  相似文献   

6.
郭启雷  王浩  杨红梅  刘艳琴  曹红 《质谱学报》2009,30(Z1):162-164
A triple quadrupole liquid chromatography tandem mass spectrometry method is presented for the quantitative determination and confirmation of salbactam and tazobactam, the inhibitors of β-lactamase in milk. Milk was extracted with methanol, and the extracts were analyzed by LC-MS/MS in negative mode. The LOQs of salbactam and tazobactam in milk are 10 μg•L-1 and 100 μg•L-1, respectively.  相似文献   

7.
王博雅  赵芊  江骥  胡蓓 《质谱学报》2009,30(Z1):107-108
A sensitive liquid chromatography-electrospray ionization-tandem mass spectrometric(LC-MS/MS) method for the determination of CPRC-127 in human plasma was developed and validated. The plasma was extracted using a liquid-liquid phase extraction(LLE), and the sample extract was injected onto the LC-MS/MS system. The limit of quantitation(LLOQ) for CPRC-127 is 0.5 μg•L-1. This method allows the reproducible and accurate quantification with the concentration range of 0.5-1 000 μg•L-1. This method can be applied to the quantitation of CPRC-127 in human plasma.  相似文献   

8.
Melamine in milk power was determined by gas chromatography-mass spectrometer(GC/MS) made in china. The results show that the method has a good liner range between 0.005 mg•L-1 and 2 mg•L-1, R2 is 0.999 7. The limit of detection is 0.001 mg•L-1, the quantitative detection limit is 0.02 mg•kg-1. The recovery for melamine is in the range of 94%-102%. The method has good sensitivity, selectivity and repeatability, which has been applied to the determination of melamine in milk powder.  相似文献   

9.
郭然  罗海 《质谱学报》2009,30(Z1):139-140
A desorption electrospray ionization mass spectrometry(DESI-MS) method was developed to determine methylglyoxal(MG) present in beers. This method utilized 1,2-diamino-4,5-dimethoxybenzene to convert MG to 6,7-dimethoxy-2-methylquinoxaline, and then determined the derivative by DESI-MS. 1×10-5 mol•L-1 MG in water and 5×10-5 mol•L-1 MG in Yan Jing beer can be determined using this method. This time-saving method may provide a way for high-throughput analysis of MG in beverages.  相似文献   

10.
刘明  周辉  江骥  胡蓓 《质谱学报》2009,30(Z1):105-106
A sensitive liquid chromatography-electrospray ionization-tandem mass spectrometric(LC-MS/MS) method for the simultaneous determination of TF and its metabolites M1 and M2 in human plasma were developed and validated. The plasma TF, M1, M2 were extracted using a solid phase extraction(SPE), and the sample extract was injected onto the LC-MS/MS system. The limits of quantitation(LLOQ) for TF, M1, M2 are 1 ng•L-1. This method allowes the reproducible and accurate quantification with the concentration range of 1-500 ng•L-1. This method can be applied to the quantitation of TF, M1, M2 in human plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号