首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
目的 探讨人工髋关节置换治疗高龄非稳定性股骨转子间骨折的疗效.方法 23例高龄非稳定性股骨转子间骨折患者,6例行全髋关节置换,17例行人工双极股骨头置换.所有病例均使用人工加长柄型骨水泥假体.结果 23例均获随访,时间6~36个月,未发现假体松动、脱位、下沉及感染,髋关节功能接近伤前水平,基本能生活自理,其中3例类风湿性关节炎患者术后关节功能较术前明显改善.结论 人工髋关节置换治疗高龄非稳定性股骨转子间骨折是一种效果确切的治疗方法,可早期下地锻炼,减少并发症和病死率,提高老年人的生存质量.  相似文献   

2.
目的探讨采用骨水泥加长柄人工股骨头置换治疗高龄患者不稳定股骨转子间骨折的疗效。方法对24例高龄不稳定股骨转子间骨折患者采用加长柄骨水泥人工股骨头置换治疗。结果 24例获随访,时间8~20个月。术后髋关节功能按Harris评分评定:优良率87.5%(21/24)。患者术后无切口感染、假体脱位及假体松动等并发症。结论骨水泥加长柄人工股骨头置换治疗高龄不稳定股骨转子间骨折,术后早期下床活动及负重功能锻炼,减少术后并发症,促进髋关节功能良好恢复,但应严格掌握适应证。  相似文献   

3.
目的探讨骨水泥加长柄人工髋关节置换治疗高龄不稳定型股骨转子间骨折的临床疗效。方法对32例高龄不稳定型股骨转子间骨折患者采用经髋关节外侧切口前方入路骨水泥加长柄人工髋关节置换治疗。结果 30例获得随访,时间18~36个月。按Harris评分标准进行功能评定:优10例,良16例,可3例,差1例,优良率为86.7%。无人工关节脱位、假体关节感染、假体松动、下沉、钢丝断裂等并发症发生。结论骨水泥加长柄人工髋关节置换治疗高龄不稳定型股骨转子间骨折安全、有效。  相似文献   

4.
目的探讨人工股骨头置换治疗老年不稳定股骨转子间骨折的临床效果。方法对17例老年不稳定股骨转子间骨折患者行骨水泥型股骨头置换及转子间重建,术后早期进行功能锻炼。结果手术时间55~95 min,术中出血量100~500 ml。1例术后出现下肢静脉血栓。17例均获随访,时间8~21个月。末次随访髋关节功能Harris评分:优8例,良6例,可2例,差1例。结论应用骨水泥人工股骨头置换治疗不稳定股骨转子间骨折,可缩短患者卧床时间,减少并发症发生;早期进行患髋功能锻炼,有利于康复,且疗效可靠。  相似文献   

5.
目的探讨高龄不稳定股骨转子间骨折行骨水泥型人工股骨头置换的近期疗效。方法对21例高龄股骨转子间骨折患者采用骨水泥型人工股骨头置换治疗。根据Harris评分和X线评估临床效果。结果 21例均获随访,时间12~36(24±3)个月。患者髋关节功能均恢复良好,未发现髋内翻、感染、松动、脱位者;1例下肢深静脉血栓形成,经保守治疗后好转。Harris髋关节功能评分由术前的27分±6分提高至术后1年的90分±2分,其中优9例,良10例,中2例。结论人工股骨头置换治疗高龄股骨转子间骨折,术后可早期负重,提高生活质量,近期疗效满意。  相似文献   

6.
下肢     
股骨近端髓内钉与动力髋螺钉治疗老年股骨转子间及转子下骨折的比较研究;多孔减压加金葡液注入治疗早期股骨头坏死;80岁以上股骨颈骨折患者人工股骨头置换手术后生活质量评价;加压空心螺钉内固定与人工髋关节置换术治疗老年股骨颈骨折的疗效比较;PFN和DHS治疗股骨转子间骨折的生物力学研究及临床疗效观察;关节镜下应用带血管蒂骨瓣转移治疗股骨头缺血性坏死;股骨颈完全疲劳骨折三例临床分析;特制股骨假体置换治疗老年粗隆部不稳定骨折;90岁以上非稳定性股骨转子间骨折患者人工股骨头置换术;  相似文献   

7.
髋关节置换术治疗股骨转子间骨折内固定失败   总被引:6,自引:1,他引:5       下载免费PDF全文
 目的 回顾性分析采用髋关节置换术治疗股骨转子间骨折内固定失败的临床效果。方法2004年7月至2006年6月,采用髋关节置换术治疗32例股骨转子间骨折内固定失败患者,男24例,女8例;行关节置换时的年龄为57~81,平均71岁;从骨折到行关节置换的时间为5~70个月,平均40个月。骨折内固定方式包括:滑动髋螺钉15例,髓内钉10例,钢板5例,多枚螺钉2例。失败原因:拉力螺钉切出股骨头8例,骨折不愈合9例,股骨头缺血性坏死7例,创伤性关节炎8例。采用全髋关节置换术28例(全部为生物型髋臼),双极人工股骨头置换术4例。骨水泥型股骨柄12例,非骨水泥型股骨柄20例。标准股骨假体25例,长柄股骨假体7例。结果术后28例患者获得随访,随访时间4~6年,平均5年。28例患者术前H arris评分平均37分(32~45分),末次随访时平均88分(84~95分);优6例,良14例,可7例,差1例。末次随访时X线片显示假体位置正常,髋臼平均外展角为44°(42°~48°),髋臼假体无松动。根据Harris标准评价骨水泥型股骨假体固定,1例为A级,9例为C级。根据Engh等标准评价非骨水泥型股骨假体的固定,18例均评价为骨长入。3例髋关节术后6个月复查时发现异位骨化,BrookerⅡ级2例,Ⅲ级1例。结论髋关节置换术是老年患者股骨转子间骨折内固定治疗失败后的一种有效挽救选择。  相似文献   

8.
高龄股骨转子间骨折人工股骨头置换   总被引:18,自引:2,他引:16  
目的通过一组病例的回顾性分析,对人工股骨头置换治疗高龄股骨转子间骨折的疗效进行评价并探讨其适应证。方法于1994年至2002年对收治的16例股骨转子间骨折的患者进行了人工股骨头置换治疗。男性4例,女性12例,年龄82~91岁,平均86岁。2例为内固定失败骨不愈合病例,其余14例为新鲜骨折,假体均为骨水泥型。随访时间3~8a,平均5a。结果1例术后1a因肺心病死亡,2例假体下沉,轻至中度髋痛,其余在随访期无行走时疼痛,生活自理,无髋臼磨损及假体脱位病例。结论人工股骨头置换治疗高龄股骨转子间骨折是可取的。  相似文献   

9.
目的探讨非骨水泥型假体人工股骨头置换术治疗老年股骨颈骨折的疗效与注意事项。方法回顾性分析自2016-01—2019-12采用非骨水泥型假体人工股骨头置换术治疗的71例老年股骨颈骨折,末次随访时采用髋关节功能Harris评分评定疗效,观察并发症发生情况。结果 71例均获得随访,随访时间平均18(12~36)个月。所有患者均在术后2周内下床不负重行走,无髋关节脱位倾向。术后4周所有患者步态恢复正常。末次随访时髋关节功能Harris评分为(86.36±9.67)分,较术前明显改善。术后3例出现肺部感染,对症治疗后痊愈;2例发生股骨假体远端股骨干骨折,采用切开复位内固定手术治疗。结论非骨水泥型假体人工股骨头置换术治疗老年股骨颈骨折手术时间缩短,术中出血量减少,可避免出现骨水泥植入综合征,降低手术风险。非骨水泥型假体置入后依靠骨组织长入使骨与假体表面形成紧密的生物固定,进而实现良好的骨传导,但是需要注意防范早期假体松动与假体周围骨折。  相似文献   

10.
目的 评价采用髋关节置换术治疗老年髋部骨折内固定失败的临床效果.方法 回顾性分析2003年7月至2011年6月,采用髋关节置换术治疗老年髋部骨折内固定失败并获得完整随访资料者22例,男12例,女10例;行髋关节置换术的年龄为65~82岁,平均72岁;从骨折到行髋关节置换的时间为8~71个月,平均41个月.骨折内固定方法是多枚螺钉12例,滑动髋螺钉6例,股骨近端髓内钉2例,股骨近端钢板2例.失败原因是拉力螺钉切出股骨头7例,骨折不愈合6例,股骨头缺血性坏死5例,创伤性骨关节炎4例.术前患髋Harris评分平均37分(32~45分),采用非骨水泥型全髋置换l1例,骨水泥型全髋置换4例,非骨水泥型半髋置换4例,骨水泥型半髋置换3例.标准柄股骨假体1 5例,长柄股骨假体7例.结果 22例均获随访,随访时间1~5年,平均2.5年.末次随访时Harris评分平均88分(84~95分),优7例,良11例,可3例,差1例,优良率81.8%.无假体松动和下沉.结论 髋关节置换术是治疗老年髋部骨折内固定失败后的一种有效挽救关节功能的选择.  相似文献   

11.
Background : We investigated the vasopressor hormone response following mesenteric traction (MT) with hypotension due to prostacyclin (PGI2) release in patients undergoing abdominal surgery with a combined general and epidural anesthesia. Methods : In a prospective, randomized, placebo-controlled study we administered 400 mg ibuprofen (i.v.) in 42 patients scheduled for abdominal surgery. General anesthesia was combined with epidural anesthesia (T4-L1). Before as well as 5, 15, 30, 45, and 90 min after MT we recorded plasma osmolality, hemodynamics and measured 6-keto-PGFlα (stabile metabolite of PGI2), TXB2 (stabile metabolite of thromboxane A2) active renin, and arginine vasopressin (AVP) plasma concentrations by radioimmunoassay. Catecholamine levels were assessed by high-pressure liquid chromatography (HPLC) with electrochemical detection. Results : Following MT, arterial hypotension occurred along with a substantial PGI2 release. This was completely abolished by ibuprofen administration. Although plasma levels of 6-keto-PGF (1133 (708) vs. 60 (3) ng/L, median (median absolute deviation), P=0.0001, placebo vs. ibuprofen) remained significantly elevated, blood pressure was restored within 30 min after MT in the placebo group. At the same point in time plasma concentrations of TXB2 (164 (87) vs. 58 (1) ng/L, P=0.0001), epinephrine (46 (33) vs. 14 (6) ng/L, P=0.001), AVP (41 ± (18) vs. 12 (7) ng/L, P=0.0004), and active renin (27 (12) vs. 12 (4) ng/L, P = 0.001) were significantly higher in placebo-treated patients. Conclusion : Under combined general and epidural anesthesia arterial hypotension following MT due to endogenous PGI2 release is associated with enhanced release of AVP, active renin, epinephrine and thromboxane A2, presumably contributing to hemodynamic stability within 30 min after MT.  相似文献   

12.
Background: Halothane inhibits in vitro and in vivo activity of cytochrome P-450 (CYP) 2E1. There are several fluorinated volatile anaesthetics besides halothane, and most of them are defluorinated by CYP2E1. It is unclear whether other fluorinated anaesthetics inhibit the in vivo activity of CYP2E1.
Methods: We compared the inhibitory effects of therapeutic concentrations of four inhalational anaesthetics, halothane, enflurane, isoflurane, and sevoflurane, on chlorzoxazone metabolism in rabbits receiving artificial ventilation.
Results: All four inhalational anaesthetics decreased arterial blood pressure and increased plasma chlorzoxazone concentration. However, no significant differences in the plasma chlorzoxazone concentration were found between the four anaesthetics. The estimated chlorzoxazone clearance increased after beginning inhalation with all four agents, but no significant difference in clearance was noted between agents.
Conclusions: At therapeutic concentrations, the in vivo inhibitory effect on chlorzoxazone metabolism was similar for all four inhalational anaesthetics examined, even though their chemical characteristics and extent of hepatic metabolism differ considerably.  相似文献   

13.
Abstract: A variety of protein-bound or hydrophobic substances, accumulating as a result of pathologic conditions such as exogenous or endogenous intoxications, are removed poorly by conventional detoxification methods because of low accessibility (hemodialysis), insufficient adsorption capabilities (hemosorption), low efficiency (peritoneal dialysis), or economic limitations (high-volume plasmapheresis). Combining advantages of existing methods with microspheric technology, a module-based system was designed. Major operating parameters of the latter can be modified to allow for adjustment to individual clinical situations. An extracorporeal blood circuit including a plasmafilter is combined with a secondary high-velocity plasma circuit driven by a centrifugal pump. Different microspheric adsorbers can be combined in one circuit or applied in sequence. Thus, a prolonged treatment can be tailored using specially designed selective adsorber materials. Comparing this system with existing methods (high-flux hemodialysis, molecular adsorbent recycling system), results from our in vitro studies and animal experiments demonstrate the superior efficiency of substance removal.  相似文献   

14.
Background: The duration of action of muscle relaxants is poorly correlated to the rate of decay of their plasma concentration. The plasma concentration of mivacurium may rapidly decrease below its active concentration because of the extensive hydrolysis of mivacurium. By inflating a tourniquet on one upper limb for 3 min after the administration of atracurium, mivacurium or vecuronium, we studied the influence of the initial decline of their plasma concentration on their effect. Methods: In 50 patients anaesthetised with thiopental, isoflurane and fentanyl, the effect of bolus doses of 0.15 or 0.25 mg . kg?1 mivacurium (MIV 15, MIV 25), 0.3 or 0.5 mg . kg?1 atracurium (ATR 30, ATR 50) and 0.06 or 0.1 mg . kg?1 vecuronium (VEC 06, VEC 10) were measured on both arms (evoked response of the adductor pollicis to train-of-four stimulation every 12 s), a tourniquet being applied on one arm just before and during 3 min after the muscle relaxant bolus. Results: Tourniquet inflation of 3 min almost abolished the neuromuscular effect of mivacurium. In the vecuronium groups and in the ATR 50 group, tourniquet inflation did not modify the maximum degree of depression of the twitch response. Also, the duration of action of vecuronium was unaffected by the tourniquet. In the ATR 30 group, times to return of the twitch response to 25% (duration 25%) and 75% (duration 75%) of control response were significantly shorter in the cuffed arm, 23 min vs 27 min, and 41 min vs 45 min, respectively. In the ATR 50 group, only duration 25% was significantly shorter in the cuffed arm (41 min vs 45 min). Conclusion: The results suggest that the rate of decline of the plasma concentration of mivacurium is so rapid, that a very low and almost clinically ineffective concentration is present as soon as 3 min after its administration. The results also indicate that the recovery from a mivacurium-induced neuromuscular blockade is not influenced by the rate of decay of its plasma concentration in patients with genotypically normal plasma cholinesterase.  相似文献   

15.
Abstract: Membrane processes play a pivotal and enabling role in modern replacement therapy for acute and chronic organ failure and in the management of immunologic diseases. In fact, virtually all contemporary extracorporeal blood purification methods employ membrane devices, and the next generation of artificial organs and tissue engineering therapies are almost certain to be similarly grounded in membrane technology. In this short essay, we comment on the similarities and differences among synthetic membranes and their natural counterparts and also provide a critical overview of the demographics and technology of hemodialysis, hemofiltration, apheresis, oxygenation, and emerging membrane technologies and applications.  相似文献   

16.
Background: Obesity is increasing globallly, including in the formerly "Eastern Bloc" countries. Methods: A survey was made of obesity and bariatric surgery. Results: In the 8 East and Central European countries studied, with total population 300 million, roughly 43% of the population was overweight (BMI 25-30), 23% obese (BMI > 30), with about 15 million people morbidly obese (BMI > 40). From 0-10 morbidly obese individuals/100,000/year undergo bariatric surgery. Conclusion: Most countries were found to provide inadequate treatment for obesity.The majority of the morbidly obese are not treated effectively. However, health-care awareness of obesity and bariatric surgeons are slowly increasing.  相似文献   

17.
Abstract: Numerous articles have been published on the multiple use of dialyzers and on the effect of different reprocessing chemicals and techniques on the dialyzer biocompatibility and performance. The results often appear contradictory, especially those comparing standard biocompatibility parameters. Despite this confusion, a discerning review of the published works allows certain limited conclusions to be drawn. Reprocessing of used hemodialyzers changes the biocompatibility profile of a dialyzer as defined by the parameters complement activation. leukopenia, and cytokine release. The effect of reprocessing depends on the chemicals and reprocessing technique applied and also on the type of membrane polymer being subjected to the reprocessing procedure. Reports of pyrogenic reactions indicate that the flux of the membrane also influences how suitable it is for safe reuse. An increased risk of allergic and pyrogenic reactions appears to be associated with dialyzer reuse. Furthermore, there has been a lack of investigations into the immunologic effect of the layer of adsorbed and chemically altered proteins that remains on the inner surface of reprocessed dialyzers. We conclude that the clinical benefit of dialyzer reuse cannot be generally accepted from a biocompatibility point of view.  相似文献   

18.
Background: Catecholaminergic support is often used to improve haemodynamics in patients undergoing major abdominal surgery. Dopexamine is a synthetic vasoactive catecholamine with beneficial microcirculatory properties. Methods: The influence of perioperative administration of dopexamine on cardiorespiratory data and important regulators of macro- and microcirculation were studied in 30 patients undergoing Whipple pancreaticduodenectomy. The patients received randomized and blinded either 2 μg · kg?1 · min?1 of dopexamine (n=15) or placebo (n=15, control group). The infusion was started after induction of anaesthesia and continued until the morning of the first postoperative day. Endothelin-1 (ET-1), vasopressin, atrial natriuretic peptide (ANP), and catecholamine plasma levels were measured from arterial blood samples. Measurements were carried out after induction of anaesthesia, 2 h after onset of surgery, at the end of surgery, 2 h after surgery, and on the morning of the first postoperative day. Results: Cardiac index (CI) increased significantly in the dopexamine group (from 2.61±0.41 to 4.57±0.78 1 · min?1 · m?2) and remained elevated until the morning of the first postoperative day. Oxygen delivery index (DO2I) and oxygen consumption index (VO2I) were also significantly increased in the dopexamine group (DO2I: from 416±91 to 717±110 ml/m2 · m2; VO2I: from 98±25 to 157±22 ml/m2 · m2), being significantly higher than in the control group. pHi remained stable only in the dopexamine patients, indicating adequate splanchnic perfusion. Vasopressive regulators of circulation increased significantly only in the untreated control patients (vasopressin: from 4.37±1.1 to 35.9±12.1 pg/ml; ET-1: from 2.88±0.91 to 6.91±1.20 pg/ml). Conclusion: Patients undergoing major abdominal surgery may profit from prophylactic perioperative administration of dopexamine hydrochloride in the form of improved haemodynamics and oxygenation as well as beneficial influence on important regulators of organ blood flow.  相似文献   

19.
Background: It has been shown that the depressive effects of both propofol and midazolam on consciousness are synergistic with opioids, but the nature of their interactions on other physiological systems, e. g. respiration, has not been fully investigated. The present study examined the effect of propofol and midazolam alone and in combination with fentanyl on phrenic nerve activity (PNA) and whether such interactions are additive or synergistic. Methods: PNA was recorded in 27 anaesthetised and artificially ventilated rabbits. In three groups, propofol, fentanyl and midazolam were administered intravenously in incremental doses to construct dose-response curves for the depressant effects of each one on PNA. In another two groups, the effect of pretreatment with either fentanyl 1 μg · kg?1 i. v. or midazolam 0.05 mg · kg?1 i. v. on the effects of propofol and fentanyl respectively on PNA were studied. Results: Propofol and fentanyl caused a dose-dependent depression of PNA with complete abolition at the highest total doses of 16 mg · kg?1 i. v. and 32 μg · kg?1 i. v., respectively. In contrast, midazolam in incremental doses to a total of 0.8 mg · kg?1 reduced mean PNA by 63%, but approximately 12% of PNA remained at a total dose as high as 6.4 mg · kg?1. The mean ED50s, calculated from dose-response curves, were 5.4 mg · kg?1, 3.9 μg · kg?1 and 0.4 mg · kg?1 for propofol, fentanyl and midazolam, respectively. Initial doses of either fentanyl 1 μg · kg?1 i. v. or midazolam 0.05 mg · kg?1 i. v. acted synergistically with subsequent doses of either propofol or fentanyl to abolish PNA at total doses of 8 mg · kg?1 and 8 μg · kg?1, respectively. Conclusion: Fentanyl has a synergistic interaction with both propofol and midazolam on PNA and hence potentially on respiration.  相似文献   

20.
Background : Ketamine in sub-dissociative doses has been shown to have analgesic and phantom-Limb pain, where conventional treatment has often failed. Chronic ischemic pain due to lower extremity arteriosclerosis obliterans often responds poorly to analgesics, and the pain-generating mechanisms are not well understood.
Methods : Eight patients with rest pain in the lower extremity due to arteriosclerosis obliterans were given sub-dissociative doses of 0.15, 0.30, or 0.45 mg/kg racemic ketamine and morphine 10 mg as a 5-min infusion on four separate days in a cross-over, double-blind, randomised protocol. Plasma levels of (S)- and (R)-ketamine and their nor-metabolites were analysed with an enantioselective high-performance liquid chromatography (HPLC) method. Pain levels were evaluated with a visual analogue scale (VAS).
Results : Individual pain levels were highly variable during and after all the infusions but the pooled pain levels showed a dose-dependent analgesic effect of ketamine with a transient but complete pain relief in all patients at the highest dose (0.45 mg/ kg). Side-effects, mainly disturbed cognition and perception, were pronounced and dose-dependent. Morphine 10 mg had an analgesic peak at 20 min and 5/8 patients had complete pain relief. The remaining 3 patients also had high baseline pain scores, indicating a higher analgesic potency for the 0.30 and 0.45 mg/ kg ketamine doses than for morphine 10 mg.
Conclusion : We have demonstrated a potent dose-dependent analgesic effect of racemic ketamine in clinical ischemic pain. Due to a narrow therapeutic window, this analgesic effect is probably best utilised in combination with other analgesics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号