摘    要:阐述了清除煤气中焦油雾的必要性以及电捕焦油器清除焦油雾的工作原理,详细记载了电捕焦油器的工作异常现象,通过对两个电捕焦油器工作效率的比较,得出第二个电捕焦油器已出现故障的结论,分析了电捕焦油器效率降低的原因及处理过程,并提出了电捕焦油器使用时的注意事项。

关 键 词:电捕  效率  处理  问题

Failure Analysis of Electrical Tar Trap in Coking Plant and Solutions
LIU Li-juan.Failure Analysis of Electrical Tar Trap in Coking Plant and Solutions[J].Liaoning Chemical Industry,2009,38(9):654-656.
Authors:LIU Li-juan
Affiliation:LIU Li-juan (Tangshan Zhengnan Coking Co. Ltd, Tangshan 063000, China)
Abstract:Necessity of removing the tar fog in coal gas and work principle of electric tar trap were introduced, as well as abnormal phenomenon in operation of the electric tar trap. By comparing the work efficiency of two electro tar precipitators, the second electro tar precipitator was proved to go wrong. Reasons for low efficiency of the electro tar precipitator as well as solutions were analyzed. At last , points for attention in Using the electro tar precipitator were put forward.
Keywords:Electro tar precipitator  Efficiency  Solutions  Problem