排序方式: 共有120条查询结果,搜索用时 15 毫秒
1.
射频相位参考线是粒子加速器的重要组成部分之一,为射频低电平控制系统(LLRF)、束流诊断系统、定时系统等提供稳定的相位锁定参考信号。为减少远距离传输过程中由环境温度变化导致的射频传输线中的射频相位漂移,多个加速器装置中已经采用射频相位参考线提供射频相位参考,这些相位参考的实现方案主要是基于恒温控制和基于光纤锁相。与这些方案相比,采用相位平均方法不仅可以保持长距离节点之间的相位稳定,而且更易于现场安装与维护。现有的带有锁相环(PLL)的终端短路方式实现相位平均参考线的方案仍有一些节点数量限制等方面的不足,本文对相位平均参考线结构进行了去除PLL的简化设计并进行了验证,以期增加更多的相位分配节点以及降低对射频器件参数的要求。对非PLL的单端输入终端短路相位平均方案与两端输入各节点间互为参考的相位平均方案分别进行了实验测试,结果表明两者的相位RMS精度可以达到0.1°~0.3°。并对不同的相位平均实现方案中相位不稳定的产生原因进行了分析,结果表明,除环境温度外,同轴线缆材质、合成相位与幅度的不平衡合成等也是重要影响因素。 相似文献
2.
3.
The tuning process of the three-dimensional electric field near the beam axis is very important in the optimization of the Interdigital H-mode Drift Tube Linac (IH-DTL). The tuning of the longitudinal field distribution, the Kilpatrik (Kp) factor, and the transverse dipole field have been discussed in detail, combined with the radio-frequency tuning process of the 53.667 MHz short IH-DTL cavity, which was designed to accelerate 238U34+ from 0.143 MeV/u to 0.289 MeV/u in the SSC-Linac injector project at the Institute of Modern Physics. The flatness criterion and the tube tuning method are discussed in order to meet the beam dynamics requirements. In the tube tuning process, the energy gain error in the cells should be reduced to less than ±2%, and the Kp factor should be reduced to 1.6. The transverse dipole field and the method that uses a "plunger" to dismiss this dipole field are evaluated. The experience gained from the first cavity optimization benefits the tuning process of the three remaining IH-DTL cavities in the SSC-Linac project. 相似文献
4.
利用FEM软件ANSYS对德国GSI的FAIR项目的超导二极铁的超导线进行了失超模拟.该模拟形象地给出导线的失超过程,通过APDL编程可以得到失超传播速度,失超时导体的端电压随时间的变化.文章还进一步研究了导线的最小失超传播区域MPZ,失超段初始温度和电流对失超传播速度的影响. 相似文献
5.
常玮 何源 文良华 李春龙 薛纵横 宋玉堃 张锐 朱正龙 高郑 张聪 孙列鹏 岳伟明 张生虎 游志明 Thomas Joseph PowersTom Powers 《中国物理C(英文版)》2014,(5):82-86
To test superconducting cavities, a vertical test system has been designed and set up at the Institute of Modern Physics (IMP). The system design is based on VCO-PLL hardware and the NI Labview software. The test of the HWR010#2 superconducting cavity shows that the function of this test system is satisfactory for testing the low frequency cavity. 相似文献
6.
To investigate the feasibility of using a form cutter to machine the Radial Matcher Section (RMS) of the Radio Frequency Quadrupole (RFQ) for the Accelerator Driven System (ADS) project at Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS), the influence of RMS end shape on the RFQ cavity frequency is studied. The results indicate that using a form cutter to machine the RMS of an RFQ will indeed influence the cavity frequency. The RMS end shape will give more influence to a shorter RFQ cavity. For the 4.2 m ADS RFQ, the influence is negligible, which means that a form cutter can be used to machine the RMS. 相似文献
7.
The China Accelerator Driven Subcritical System (China-ADS) project, which is a strategic plan and aims to design and build an ADS demonstration facility, has been proposed and launched actively in China. Injector Ⅱ as one of the parallel injectors of China-ADS, and is prompted by the Institute of Modern Physics (IMP). In this paper, a new scheme with full period lattice structure for the SC section is proposed. In the new scheme, there are sixteen periods, with one superconducting solenoid and one superconducting cavity included in each period. All of the elements are contained in four cryomodules. The dreadful influence of the mismatch caused by period structural change can be avoided, and the beam quality is favorable. In addition, this new scheme has certain advantages in reducing the project's difficulty and construction risk. The details of the design and beam dynamic simulation for the full period lattice structure are given in this paper. 相似文献
8.
To test superconducting cavities, a vertical test system has been designed and set up at the Institute of Modern Physics (IMP). The system design is based on VCO-PLL hardware and the NI Labview software. The test of the HWR010#2 superconducting cavity shows that the function of this test system is satisfactory for testing the low frequency cavity. 相似文献
9.
10.