排序方式: 共有4条查询结果,搜索用时 0 毫秒
1
1.
为ITER CC 10 kA高温超导电流引线服务的低温性能测试装置已研制完成,并成功运行。其低温系统主要由500W/4.5 K氦制冷机,真空杜瓦,低温组件(低温阀门,过冷槽,管道加热器,热防护层),汽化器及低温传输管线等部分组成。本文对真空杜瓦和过冷槽进行设计,并讨论该低温系统的冷却流程方案,最后通过电流引线10 kA稳态实验结果对低温系统的运行效果进行分析,结果表明该低温系统运行稳定,能满足ITER CC电流引线的测试需要。 相似文献
2.
3.
An experimental Paschen test setup has been established to analyze the quality of ITER current lead (CL) insulation and extend the research on Paschen’s law under various conditions. Insulation problems can destroy a machine if a Paschen discharge is triggered by an insulation defect that is caused by faulty manufacturing, electromagnetic force, and thermal stress load with a certain degree of vacuum helium or pipe leakage. The results show that the CL insulation mock-up worked well under normal temperature and pressure. Besides, the mock-up also worked well in helium conditions and at 80 K temperature at different pressures. One area of CL insulation was severely destroyed when the 80 K test was conducted after 5 thermal cycles, resulting in Paschen discharge phenomenon. The breakdown voltage is maintained at a relatively low level under different pressure conditions; the change of breakdown voltage was mainly due to the change of pressure, and such change was in line with the Paschen law. 相似文献
4.