排序方式: 共有67条查询结果,搜索用时 15 毫秒
51.
WANG Xiao-Liang CHEN Yuan-Bo LIN Jian-Feng ZHANG Jia-Quan XU Yu-Lin XU Rong-Feng XIE Yi-Gang 《中国物理C(英文版)》1987,11(1):6-10
In this paper the structure and the induced readout characteristics of a new type of plastic streamer tube is introduced. The relation between charge distribution spectra and high voltage on the induced strips and the charge distribution on the adjacent strips have been studied. The spatial resolution has also been measured and calculated. It is pointed out that the two peak effect in the distribution spectra is caused by the nearer and farther streamers from two sides of anode wire to strips. At last, some preliminary results of the induced pads as a readout mode are reported. 相似文献
52.
为研发能够满足北京同步辐射(BSRF)实验要求的二维探测器,研制了基于读出条读出的二维位置灵敏X射线气体电子倍增器(GEM).实验过程中通过改进读出条的周期,并基于中科院高能所实验物理中心电子学组研制的多路电荷放大器系统与VME存储-ADC系统,对软X射线源的位置分辨率进行了精密测量且得到了优异的二维位置分辨:X方向约为84μm,Y方向约为75μm.研究了三级GEM压差之和对位置分辨的影响,并测试了探测器的位置准确度与线性.对基于阳极读出的GEM用于模拟读出测试系统得到了一定的理论认识,侧重研究了GEM探测器基于模拟读出的系统特性,给出了相关的分析与讨论. 相似文献
53.
54.
55.
利用数值仿真开展了侧风条件下短舱流动分离等离子体流动控制研究,首先研究了不同侧风条件下短舱流动分离特性,揭示了侧风角度以及速度大小对流动分离的影响规律。随着侧风角度的增加,进气唇口处分离区域不断扩大且进气截面的总压损失更加严重;随着侧风速度的变大,分离区域变化并不明显,进气截面总压损失系数降低。进一步将等离子体激励布置于短舱内表面,在典型工况下研究了等离子体激励抑制短舱流动分离的规律,结果表明,在分离起始点的上游同时施加多组激励具有最优的控制效果,平均总压损失降低了21.3%. 相似文献
56.
以Ce3+为中心离子,N,N-二甲基甲酰胺(DMF)为有机配体,通过温度调节,合成系列形貌和电化学信号不同的铈配合物(Ce-COPs)。筛选出电化学信号最强的多面体状Ce-COP为信号探针。通过凝血酶(TB)与TB适体链之间的特异性识别作用,设计了一种简单通用的TB适体传感器。最优实验条件下,该传感器对TB的线性响应范围为1.0 fmol·L-1~1.0 nmol·L-1,检测限为0.94 fmol·L-1。此外,本方案方法与商品人凝血酶(TM) ELISA试剂盒检测结果相近。结果表明,构建的传感器具有良好的灵敏度、特异性、选择性和稳定性。 相似文献
57.
XU Mei-Hang LIU Rong-Guang ZHU Qi-Ming ZHANG Jian HUANG Jie CHEN Chang CHEN Yuan-Bo WU Zhi QIN Zhong-Hua WU Ling-Hui LIU Jian-Bei WANG Lan JIN Yan 《中国物理C(英文版)》2008,32(12)
After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber,a full system covering all the channels of high voltage was installed.The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber.The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported.The full system of high voltage power supply works stably and reliably. 相似文献
58.
小单元漂移室用放射源模拟老化的实验研究 总被引:2,自引:0,他引:2
BESⅢ 漂移室(DC)模型用1.85X109 Bq 55Fe 5.9keV X射线放射源作加速老化实验研究.测量了阳极丝电流I和55Fe 5.9keV X射线全能光电峰位随累积电荷量Q的变化,由此得到累积相当BESⅢ DC 5年全天候运行的电荷量(0.07 C/cm)后,漂移室小单元的阳极电流降为初始值的87%;老化率为R=-0.19%/(mC/cm) 相似文献
59.
60.
精确测量离子与原子碰撞引起的靶原子内壳层电离截面,对研究原子内壳层过程以及建立合适的理论模型具有重要的意义.现有的实验数据和理论模型大都集中在中低能区,高能区由于受到实验条件的限制,几乎没有相关实验数据的报道,哪种理论更适合描述高能重离子入射的靶原子内壳层电离截面,还需要进行深入的实验研究.采用电子冷却存储环提供能量分别为165,300,350,430 MeV/u的C~(6+)离子束轰击Ni靶,测量Ni的K壳层X射线.分析了实验中探测到的Ni的K_β和K_α射线强度比,发现入射粒子能量的变化对该强度比影响不明显.分别应用两体碰撞近似(BEA)、平面波玻恩近似(PWBA)和ECPSSR理论对Ni的K壳层X射线的产生截面进行理论计算,并将理论结果与实验结果进行比较. 相似文献