首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The incorporation of melamine into food products is banned but its misuse has been widely reported in both animal feeds and food. The development of a rapid screening immunoassay for monitoring of the substance is an urgent requirement. Two haptens of melamine were synthesized by introducing spacer arms of different lengths and structures on the triazine ring of the analyte molecular structure. 6-Aminocaproic acid and 3-mercaptopropionic acid were reacted with 2-chloro-4,6-diamino-1,3,5-triazine (CAAT) to produce hapten 1 [3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylamino) hexanoic acid] and hapten 2 [3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylthio) propanoic acid], respectively. The molecular structures of the two haptens were identified by 1H nuclear magnetic resonance spectrometry, mass spectrometry and infrared spectrometry. An immunogen was prepared by coupling hapten 1 to bovine serum albumin (BSA). Two plate coating antigens were prepared by coupling both haptens to egg ovalbumin (OVA). A competitive indirect enzyme-linked immunosorbent assay (ciELISA) was developed to evaluate homogeneous and heterogeneous assay formats. The results showed that polyclonal antibodies with high titers were obtained, and the heterogeneous immunoassay format demonstrated a better performance with an IC50 of 70.6 ng mL−1, a LOD of 2.6 ng mL−1 and a LOQ of 7.6 ng mL−1. Except for cyromazine, no obvious cross-reactivity to common compounds was found. The data showed that the hapten synthesis was successful and the resultant antisera could be used in an immunoassay for the rapid and sensitive detection of this banned chemical.  相似文献   

2.
A novel immunoassay format employing direct coating of small molecular hapten on microtiter plates is reported for the detection of atrazine and 2,4-dichlorophenoxyacetic (2,4-D). In this assay, the polystyrene surface of microtiter plates was first treated with an acid to generate -NO2 groups on the surface. Acid treated plates were further treated with 3-aminoprpyltriethoxysilane (APTES) to functionalize the plate surface with amino groups for covalent linkage to small molecular hapten with carboxyl groups. The modified plates showed significantly high antibody binding in comparison to plates coated with hapten-carrier protein conjugates and presented excellent stability as a function of the buffer pH and reaction time. The developed assay employing direct hapten coated plates and using affinity purified atrazine and 2,4-D antibodies demonstrated very high sensitivity, IC50 values for atrazine and 2,4-D equal to 0.8 ng mL−1 and 7 ng mL−1, respectively. The assay could detect atrazine and 2,4-D levels in standard water samples even at a very low concentration upto 0.02 and 0.7 ng mL−1 respectively in the optimum working range between 0.01 and 1000 ng mL−1 with good signal reproducibility (p values: 0.091 and 0.224 for atrazine and 2,4-D, respectively). The developed immunoassay format could be used as convenient quantitative tool for the sensitive screening of pesticides in samples.  相似文献   

3.
Zhang Q  Wu Y  Wang L  Hu B  Li P  Liu F 《Analytica chimica acta》2008,625(1):87-94
Five different haptens of the N-methylcarbamate insecticide metolcarb were designed and synthesized. All of the haptens were conjugated with ovalbumin (OVA) for the coating antigen, and one hapten containing all of the structure of metolcarb was conjugated with bovine serum albumin (BSA) for the immunogen. Two polyclonal antisera were raised against the BSA conjugate, and ten antibody/coating conjugate combinations were selected for studies of assay sensitivity and specificity for metolcarb. A class-specific combination was found, with the I50 of the assay ranged from 0.64 to 20.98 μg mL−1 for seven tested N-methylcarbamate insecticides except for pirimicarb. Considering titer, I50 and cross-reactivity of all combinations of antibody/coating conjugate, a competitive indirect enzyme-linked immunosorbent assay (ELISA) in a homologous system, whose limit of detection (LoD) reached 1.4 ng mL−1, was presented. The results of competitive ELISAs indicated that coating hapten structure can significantly affect not only assay sensitivity but also its specificity.  相似文献   

4.
Zhang Y  He F  Wan Y  Meng M  Xu J  Yi J  Wang Y  Feng C  Wang S  Xi R 《Talanta》2011,83(3):732-737
Trenbolone (TRE) is a steroid used by veterinarians on livestock to increase appetite and body weight. The use of TRE has been restricted because of its harmful side effect for consumers. To effectively control TRE residue in food and food product, a rapid and convenient immunoassay was developed by preparing an anti-TRE monoclonal antibody. The immunogen and coating antigen were prepared by coupling TRE hapten with carrier proteins via 1-ethyl-3-(dimethylaminopropyl)carbodiimide hydrochloride (EDC) method. The optimized method gave an average IC50 value of 0.323 ng mL−1 towards TRE and an average detection limit (LOD) of 0.06 ng mL−1, which is much lower than the maximum residue levels (2.0 ng g−1) accepted by the Joint FAO/WHO Expert Committee on Food Additives (JECFA). The specificity of the antibody was evaluated by measuring cross-reactivity of six structurally related compounds, including 19-nortestosterone (9.7%), testosterone (0.13%), methyltestosterone (<0.01%), methandrostenolone (<0.01%), (+)-dehydroisoandrosterone (<0.001%) and β-estradiol (<0.001%). The recovery rates of the test in detection of TRE-fortified animal tissue, urine and animal feed samples were in the range of 81.3-89.4%, while the intra- and inter-assay coefficients of variation were less than 12.0%.  相似文献   

5.
Liang Y  Liu XJ  Liu Y  Yu XY  Fan MT 《Analytica chimica acta》2008,615(2):174-183
A general and broad class-specific enzyme-linked immunosorbent assay was developed for the O,O-dimethyl organophosphorus pesticides, including malathion, dimethoate, phenthoate, phosmet, methidathion, fenitrothion, methyl parathion and fenthion. Three haptens with different spacer-arms were synthesized. The haptens were conjugated to bovine serum albumin (BSA) for immunogens and to ovalbumin (OVA) for coating antigens. Rabbits were immunized with the immunogens and six polyclonal antisera were produced and screened against each of the coating antigens using competitive indirect enzyme-linked immunosorbent assay for selecting the proper antiserum. The effect of hapten heterology on immunoassay sensitivity was also studied. The antibody-antigen combination with the most selectivity for malathion was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50 values, under optimum conditions, were estimated to be 30.1 μg L−1for malathion, 28.9 μg L−1 for dimethoate, 88.3 μg L−1 for phenthoate, 159.7 μg L−1 for phosmet, 191.7 μg L−1 for methidathion, 324.0 μg L−1 for fenitrothion, 483.9 μg L−1 for methyl parathion, and 788.9 μg L−1 for fenthion. Recoveries of malathion, dimethoate, phenthoate, phosmet and methidathion from fortified Chinese cabbage samples ranged between 77.1% and 104.7%. This assay can be used in monitoring studies for the multi-residue determination of O,O-dimethyl organophosphorus pesticides.  相似文献   

6.
Melamine is a chemical product that was sporadically mixed into animal feeds to boost protein content. Excessive melamine in animal feed can induce renal failure and even death in animals. The residue of melamine in edible animal products also threatens human health. Currently, there is no real-time and high throughput method to detect residual melamine in animal tissues. Successful development of such methods is very important for fast and on-site screening of melamine residue in animal tissues to eliminate the potential threat to human health. Here we demonstrate the detection of residual melamine from swine and chicken tissues and body fluids using indirect competitive enzyme-linked immunosorbent assay (ELISA) method. A detection sensitivity of 0.5 μg mL−1 and a limit of detection of 0.05 μg mL−1 were achieved with this method. A gas chromatography-mass spectrometry (GC-MS) method was also developed to act as a confirmatory and quantitative procedure for the ELISA results. The limits of quantitation (LOQ) of were 0.01 μg g−1 and 0.005 μg mL−1 for tissues and body fluids, respectively. The two methods showed good agreement (r2 > 0.992). The method developed was performed on samples of tissues from chickens fed with melamine-spiked feed.  相似文献   

7.
Polyclonal antibody (PAb) with broad-specificity for O,O-diethyl organophosphorus pesticides (OPs) against a generic hapten, 4-(diethoxyphosphorothioyloxy)benzoic acid, was produced. The obtained PAb showed high sensitivity to seven commonly used O,O-diethyl OPs in a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using a heterologous coating antigen, 4-(3-(diethoxyphosphorothioyloxy)phenylamino)-4-oxobutanoic acid. The 50% inhibition value (IC50) was 348 ng mL−1 for parathion, 13 ng mL−1 for coumaphos, 22 ng mL−1 for quinalphos, 35 ng mL−1 for triazophos, 751 ng mL−1 for phorate, 850 ng mL−1 for dichlofenthion, and 1301 ng mL−1 for phoxim. The limit of detection (LOD) met the ideal detection criteria of all the seven OP residues. A quantitative structure-activity relationship (QSAR) model was constructed to study the mechanism of antibody recognition using multiple linear regression analysis. The results indicated that the frontier-orbital energies (energy of the highest occupied molecular orbital, EHOMO, and energy of the lowest unoccupied molecular orbital, ELUMO) and hydrophobicity (log of the octanol/water partition coefficient, log P) were mainly responsible for the antibody recognition. The linear equation was log(IC50) = −63.274EHOMO + 15.985ELUMO + 0.556 log P − 25.015, with a determination coefficient (r2) of 0.908.  相似文献   

8.
In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L−1 to as low as 0.07 μg L−1. The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step.  相似文献   

9.
The increasing global adoption of genetically modified (GM) plant derivatives in animal feed has provoked a strong demand for an appropriate detection method to evaluate the existence of transgenic protein in animal tissues and animal by-products derived from GM plant fed animals. A highly specific and sensitive sandwich enzyme immunoassay for the surveillance of transgenic Cry1Ab protein from Bt-maize in the blood plasma of cows fed on Bt-maize was developed and validated according to the criteria of EU-Decision 2002/657/EC. The sandwich assay is based on immuno-affinity purified polyclonal antibody raised against Cry1Ab protein in rabbits. Native and biotinylated forms of this antibody served as capture antibody and detection antibody for the ELISA, respectively. Streptavidin-horseradish peroxidase conjugate and TMB substrate provided the means for enzymatic colour development.The immunoassay allowed Cry1Ab protein determination in bovine blood plasma in an analytical range of 0.4-100 ng mL−1 with a decision limit (CCα) of 1.5 ng mL−1 and detection capability (CCβ) of 2.3 ng mL−1. Recoveries ranged from 89 to 106% (mean value of 98%) in spiked plasma.In total, 20 plasma samples from cows (n = 7) fed non-transgenic maize and 24 samples from cows (n = 8) fed transgenic maize (collected before and, after 1 and 2 months of feeding) were investigated for the presence of the Cry1Ab protein. There was no difference amongst both groups (all the samples were below 1.5 ng mL−1; CCα). No plasma sample was positive for the presence of the Cry1Ab protein at CCα and CCβ of the assay.  相似文献   

10.
Ji X  He Z  Ai X  Yang H  Xu C 《Talanta》2006,70(2):353-357
A competitive immunoassay for clenbuterol (CLB) based on capillary electrophoresis with chemiluminescence (CL) detection was established. The method was based on the competitive reaction of horseradish peroxidase (HRP)-labeled CLB (CLB-HRP) and free CLB with anti-CLB antiserum. The factors affecting the electrophoresis and CL detection were systematically investigated with HRP as a model sample. Under the optimal conditions, the tracer CLB-HRP and the immunoassay complex were separated, and the linear range and the detection limit (S/N = 3) for CLB were 5.0-40 nmol l−1 and 1.2 nmol l−1, respectively. The proposed method has been applied satisfactorily in the analysis of urine sample.  相似文献   

11.
The use of a functionalized latex nanoparticle coating as a new sorbent phase for solid-phase microextraction (SPME) was examined. By means of electrostatic absorption onto ionized silanol groups, a fused-silica rod was coated with polymeric nanoparticles functionalized with quaternary ammonium groups. Optimum conditions for the preparation of the coated fibre are presented. The fibre was used for the extraction of a mixture of seven anions from water samples which are analysed by coupling the SPME fibre to an ion chromatographic system via a special interface. The results obtained proved the suitability of this novel coating as a new SPME fibre. A linear calibration for the target analytes was achieved over the concentration range from 5 μg L−1 to 5 mg L−1 (r2 > 0.988), while limits of detection for these ions were all below 3.7 μg L−1 (S/N = 3). The reproducibility of a single fibre (n = 4) under similar conditions was between 7 and 12%, while the fibre to fibre reproducibility (n = 5) was between 8.9 and 14%.  相似文献   

12.
A novel procedure for parathion hapten design is described. The optimal antigen for parathion was selected after molecular modeling studies of six types of potentially immunizing haptens with the aim to identify the best mimicking target analyte. Heterologous competitive indirect enzyme-linked immunosorbent assay (ELISA) was developed after screening a battery of competitors as coating antigens. The relationship between the heterology degree of the competitor and the resulting immunoassay detectability was investigated according to the electronic similarities of the competitor haptens and the target analyte. Molecular modeling and principal component analysis were performed to understand the electronic distribution and steric parameters of the haptens at their minimum energetic levels. The results suggested that the competitors should have a high heterology to produce assays with good detectability values. An indirect competitive ELISA was finally selected for further investigation. The immunoassay had an IC50 value of 4.79 ng mL−1 and a limit of detection of 0.31 ng mL−1. There was little or no cross-reactivity to similar compounds tested except for the insecticide parathion-methyl, which showed a cross-reactivity of 7.8%.  相似文献   

13.
Liu R  Xing Z  Lv Y  Zhang S  Zhang X 《Talanta》2010,83(1):48-54
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis). The signal induced by the flash of ions (197Au+) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer. The frequency of the transient signals is proportional to the concentration of Au-NPs labels. Characteristics of the signals obtained from Au-NPs of 20, 45 and 80 nm in diameters were discussed. The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail. Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay. A detection limit (3σ) of 0.1 ng mL−1 was obtained for rabbit-anti-human IgG after immunoreactions, with a linear range of 0.3-10 ng mL−1 and a RSD of 8.1% (2.0 ng mL−1). Finally, the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples. The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay.  相似文献   

14.
A flow injection amperometric immunoassay system based on the use of screen-printed carbon electrode for the detection of mouse IgG was developed. An immunoelectrode strip, on which an immunosorbent layer and screen-printed carbon electrode were integrated, and a proposed flow cell have been fabricated. The characterization of the flow immunoassay system and parameters affecting the performance of the immunoassay system were studied and optimized. Amperometric detection at 0.0 V (versus Ag/AgCl) resulted in a linear detection range of 30-700 ng ml−1, with a detection limit of 3 ng ml−1. The signal variation among electrode strips prepared from variant batch did not exceed 8.5% (n=7) by measuring 0.5 μg ml−1 antigen standard solution.  相似文献   

15.
Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional cadmium sulphide (CdS) nanoparticles as a fluorescence probe. When Δλ (λem − λex) = 215 nm, maximum synchronous fluorescence is produced at 304 nm. Under optimal conditions, functional cadmium sulphide displayed a calibration response for silver ion over a wide concentration range from 0.8 × 10−10 to 1.5 × 10−8 mol L−1. The limit of detection was 0.4 × 10−10 mol L−1 and the relative standard deviation of seven replicate measurements for the lowest concentration (0.8 × 10−10 mol L−1) was 2.8%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

16.
A general and broad class selective enzyme-linked immunosorbent assay was developed for the type II pyrethroid insecticides, such as cypermethrin, deltamethrin, cyhalothrin, cyfluthrin, fenvalerate, esfenvalerate and fluvalinate. Polyclonal antibodies were generated by immunizing with a type II pyrethroid immunogen ((RS)-α-cyano-3-phenoxybenzyl (RS)-cis,trans-2,2-dimethyl-3-carboxyl-cyclopropanecarboxylate) conjugated with thyroglobulin. Antisera were screened against nine different coating antigens. The antibody-antigen combination with the most selectivity for type II pyrethroids such as cypermethrin was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50s of the optimized immunoassay were 78 μg l−1 for cypermethrin, 205 μg l−1 for cyfluthrin, 120 μg l−1 for cyhalothrin, 13 μg l−1 for deltamethrin, 6 μg l−1 for esfenvalerate, 8 μg l−1 for fenvalerate and 123 μg l−1 for fluvalinate. No cross-reactivity was measured for the type I pyrethroids such as permethrin, bifenthrin, phenothrin, resmethrin and bioresmethrin. This assay can be used in monitoring studies to distinguish between type I and II pyrethroids.  相似文献   

17.
A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100–200 nm for polyamide nanofibers with a homogeneous and porous surface structure. The extraction efficiency of new coating was investigated for headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency including extraction temperature, extraction time, ionic strength and polyamide amount were investigated and optimized. In order to improve the chromatographic behavior of phenolic compounds, all the analytes were derivatized prior to the extraction process using basic acetic anhydride. The detection limits of the method under optimized conditions were in the range of 2–10 ng L−1. The relative standard deviations (RSD) (n = 3) at the concentration level of 1.7–6.7 ng mL−1 were obtained between 1 and 7.4%. The calibration curves of chlorophenols showed linearity in the range of 27–1330 ng L−1 for phenol and monochlorophenols and 7–1000 ng L−1 for dichloro and trichlorophenols. Also, the proposed method was successfully applied to the extraction of phenol and chlorophenols from real water samples and relative recoveries were between 84 and 98% for all the selected analytes except for 2,4,6 tricholophenol which was between 72 and 74%.  相似文献   

18.
Fei Wang  Xiaohan Wei  Shusheng Zhang 《Talanta》2010,80(3):1198-1204
The π-A isotherms and UV-vis spectra of the transferred films suggested that the monolayer of p-tert-butylthiacalix[4]arene can coordinate with Hg2+ at the air-water surface. From these observations, a glassy carbon electrode coated with Langmuir-Blodgett film of p-tert-butylthiacalix[4] arene as a new voltammetric sensor is designed for the determination of trace amounts of Hg2+. Compared with bare glassy carbon electrode and modified glassy carbon electrode using direct coating method, the Langmuir-Blodgett film-modified electrode can greatly improve the measuring sensitivity of Hg2+. Under the selected conditions, the Langmuir-Blodgett film-modified electrode in 0.1 mol L−1 H2SO4 + 0.01 mol L−1 KCl solution shows a linear voltammetric response for Hg2+ in the range of 5.0 × 10−10 to 1.5 × 10−7 mol L−1, with a detection limit of 2.0 × 10−10 mol L−1. The proposed method was also applied to determine Hg2+ in water samples (tap, lake and river water). In addition, the fabricated electrode exhibited a distinct advantage of simple preparation, non-toxicity, good reproducibility and good stability.  相似文献   

19.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

20.
A simple and rapid homogeneous enzyme immunoassay involving the use of the malic dehydrogenase enzyme and a long-wavelength fluorophor, the oxazine Cresyl Violet, is proposed for the determination of the antibiotic amikacin in water samples. An enzymatic tracer has been synthesized by covalent binding of amikacin to malic dehydrogenase via a carbodiimide derivative. Free tracer catalyses the reaction between Cresyl Violet and malic acid giving rise to a decrease in the fluorescence of the fluorophor. Kinetic curves for this reaction have been monitored at λex 585 and λem 624 nm using the stopped-flow mixing technique, being the initial rate measured in only 2-3 s. The dynamic range of the method is 1-15 ng mL−1 and the detection limit is 0.3 ng mL−1, using aqueous standard solutions or water samples. The precision, obtained at 1 and 5 ng mL−1 and expressed as relative standard deviation, was 6.0 and 9.6%, respectively. The method has been applied to the analysis of drinking, river and wastewater samples. The sample pre-treatment involved a solid-phase extraction step for the clean-up of the samples. A recovery study was carried out to validate the method, being the values obtained in the range 80-114%, with a mean value of 96.7%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号