1.
应用B2-code模拟了偏滤器等离子体行为,优化了HL-2A装置偏滤器位形。研究了偏滤器刮削层中等离子体与器壁间过渡鞘层的离子碰撞效应,模拟研究了利用LHCD和NBI控制等离子体剖面分布在HL-2A中建立准稳态的反磁剪切位形。HL-2A装置首次实现了下单零点的偏滤器位形运行,完成了偏滤器初步物理实验,截至2004年底,获得等离子体电流320 kA,等离子体存在时间1 580 ms,环向磁场2.2 T。开展了高功率密度聚变堆偏滤器靶板的设计研究,特别是流动液态锂偏滤器靶板表面的物理过程的研究。探索性研究了用RF有质动力势改善偏滤器排灰效率和减少氚投料量。对FEB- E聚变堆偏滤器进行了优化设计。用电子束模拟对碳基材料及钨进行了高热负荷冲击实验,完成了钨/铜合金的热等静压焊接及热疲劳试验研究。研究了氦在钨中的滞留与热解吸行为。  相似文献   

2.
The heat flows out from the tokamak core region are collected on the divertor plates and external wall. Control of heat flux exhaust in the SOL and divertor plates regions is one of the important issues in tokamak physics. There are important phenomena affecting heat flows were simulated. The simulation is based on the B2SOLPS5.0 2D multifluid code. It is demonstrated that, the following results: (1) The simulation shows that, the operation of small size divertor tokamak, the divertor plate with/without impurities influence on profiles of electron, ion temperatures, and heat loads significantly. (2) Under normal direction of parallel (toroidal) magnetic field and different values of edge plasma density, strong “SOL” heat flow exists directed towards the LFS (outer) plate. (3) The simulation results show that, the increasing of the plasma density strong influence on the ion and electron poloidal heat fluxes profile significantly. The ion and electron polodial heat flux increase by factor “~8” and “2.4” times. (4) The simulation results show that the in–out asymmetry of heat fluxes was reversed when switching on/off E × B drifts in the edge plasma of this tokamak. (5) The simulation results show correlation between the in–out asymmetry divertor heat fluxes and E × B drift velocity. (6) The observed heat loads asymmetry between HFS and LFS plates can be explained with the radial electric field in SOL. (7) Also the simulation results performed result in, the in–out asymmetry strong influence on the characteristic length of ion poloidal heat flux.  相似文献   

3.
The divertor target components for the Chinese fusion engineering test reactor (CFETR) and the future experimental advanced superconducting tokamak (EAST) need to remove a heat flux of up to ~20 MW m-2.In view of such a high heat flux removal requirement,this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology.Rectangular water-cooled channels with a special thermal transfer structure (TTS)are designed in the heat sink to improve the flat-tile divertor target's heat transfer performance(HTP).The parametric design and optimization methods are applied to study the influence of the TTS variation parameters,including height (H),width (W*),thickness (T),and spacing (L),on the HTP.The research results show that the flat-tile divertor target's HTP is sensitive to the TTS parameter changes,and the sensitivity is T > L > W* > H.The HTP first increases and then decreases with the increase of T,L,and W* and gradually increases with the increase of H.The optimal design parameters are as follows:H =5.5 mm,W* =25.8 mm,T =2.2 mm,and L =9.7 mm.The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method.A flat-tile divertor mock-up is developed according to the optimized parameters.In addition,high heat flux (HHF)tests are performed on an electron beam facility to further investigate the mock-up HTP.The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m-2 under the tungsten tile thickness<5 mm and the flow speed ≥7 m s-1.The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by ~ 13% and ~30% compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock,respectively.The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of 20 MW m-2 of heat load without visible deformation,damage,and HTP degradation.The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only ~930 ℃.The fiat-tile divertor target's HTP is greatly improved by the parametric design and optimization method,and is better than the ITER-like monoblock and the fiat-tile mock-up for the WEST divertor.This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors.  相似文献   

4.
To extend the operation region of the Joint-Texas Experimental tokamak (J-TEXT) to the divertor configuration and even the H-mode, the divertor configuration discharge has been realized for the first time in the J-TEXT tokamak. Along with the establishment of a power supply for the divertor configuration, the construction of relevant diagnostics, and the installation of the divertor target on the high-field side, divertor discharge has been tested. Through the equilibrium calculation and position stability analysis, the control strategy has evolved to be more stable. High-density experiments and auxiliary heating experiments have been carried out on the divertor configuration. The special midplane single-null (MSN) divertor configuration is shown to be more stable than the limiter configuration in the density limit condition and can reach a higher density in the experiment. In the ECRH experiment, the power injection enhances the electron temperature and density, while more heat outflux is loaded on the divertor target tiles and causes more intensive recycling and impurity release. The future plan for the divertor configuration operation in the J-TEXT tokamak is also included.  相似文献   

5.
This paper reports simulation of L–H transition by fluid transport code B2SOLPS0.5.2D at low ion plasma density on neutral beam injection (NBI) in the edge plasma of small size divertor tokamak. The simulation provides the following results: (1) the transition is possible at plasma density 2 × 1019 m?3 with NBI at temperature heating Theating 3.62 keV. (2) The simulation predicts the generation of large negative radial electric field E r, which is thought to help L–H transition during NBI, is suggested in the edge plasma of small size divertor tokamak. (3) The toroidal current density in the edge plasma of small size divertor tokamak is plasma density and direction of NBI dependence. (4) Parallel flux transport by anomalous viscosity (turbulent) through separatrix leads to the variation of toroidal current density.  相似文献   

6.
HL-2M (Li, 2013 [1]) is a tokamak device that is under construction. Based on the magnetic coils design of HL-2M, four kinds of divertor configurations are calculated by CORSICA code (Pearlstein et al., 2001 [2]) with the same main plasma parameters, which are standard divertor, exact snowflake divertor, snowflake-plus divertor and snowflake-minus divertor configurations. The potential properties of these divertors are analyzed and presented in this paper: low poloidal field area around X-point, connection length from outside mid-plane to the primary X-point, target plate design and magnetic field shear. The results show that the snowflake configurations not only can reduce the heat load at divertor target plates, but also may improve the magneto-hydrodynamic stability by stronger magnetic shear at the edge. A new divertor configuration, named “tripod divertor”, is designed by adjusting the positions of the two X-points according to plasma parameters and magnetic coils current of HL-2M.  相似文献   

7.
High-density experiments in the high-field-side mid-plane single-null divertor configuration have been performed for the first time on J-TEXT.The experiments show an increase in the highest central channel line-averaged density from 2.73 x 1019 m-3 to 6.49 x 1019 m-3,while the X-point moves away from the target by increasing the divertor coil current.The corresponding Greenwald fraction rises from 0.50 to 0.79.For the impurity transport,the density normalized radiation intensity(absolute extreme ultraviolet and soft x-ray)of the central channel density decreased significantly(>50%)with an increase in the plasma density.To better understand the underlying physics mechanisms,the 3D edge Monte Carlo code coupled with EIRENE(EMC3-EIRENE)has been implemented for the first time on J-TEXT.The simulation results show good agreement with the experimental findings.As the X-point moves away from the target,the divertor power decay length drops and the scrape-off layer impurity screening effect is enhanced.  相似文献   

8.
The B2.SOLPES.0.5.2D code (Braams, Contrib Plasma Phys 36:276, 1996; Rozhansky and Tendler, Rev Plasma Phys 19:147, 1996) is applied for modeling SOL (Scrape off Layer) plasma in the small size divertor tokamak. Detailed distributions of the plasma heat flux and other plasma parameters in SOL, especially at the target plate of the divertor are found by modeling. The modeling results show that most of the electron heat flux and small part of ion heat flux arrive at target plate of the divertor, while, a large part of the ion heat flux and part of electron heat flux arrive at the outer wall. Also analysis of the role of poloidal E × B drifts in the redistribution of edge plasma is fulfilled.  相似文献   

9.
The heat flux of the HL-2M divertor would reach 10 MWm-2 or more at the local area when the device operates at high parameters.Subcooled boiling could occur at high thermal load,which would be simulated based on the homogeneous equilibrium model.The results show that the current design of the HL-2M divertor could withstand the local heat flux 10 MW m-2 at a plasma pulse duration of 5 s,inlet coolant pressure of 1.5 MPa and flow velocity of 4 m s-1.The pulse duration that the HL-2M divertor could withstand is closely related to the coolant velocity.In addition,at the time of 2 min after plasma discharge,the flow velocity decreased from 4 m s-1 to 1 m s-1,and the divertor could also be cooled to the initial temperature before the next plasma discharge commences.  相似文献   

10.
Stationary long pulse plasma of high electron temperature was produced on EAST for the first time through an integrated control of plasma shape,divertor heat flux,particle exhaust,wall conditioning,impurity management,and the coupling of multiple heating and current drive power.A discharge with a lower single null divertor configuration was maintained for 103 s at a plasma current of 0.4 MA,q_(95)≈7.0,a peak electron temperature of 4.5 keV,and a central density n_e(0)~2.5×10~(19) m~(-3).The plasma current was nearly non-inductive(V_(loop) 0.05 V,poloidal beta ~0.9) driven by a combination of 0.6 MW lower hybrid wave at 2.45 GHz,1.4 MW lower hybrid wave at 4.6 GHz,0.5 MW electron cyclotron heating at 140 GHz,and 0.4 MW modulated neutral deuterium beam injected at 60 kV.This progress demonstrated strong synergy of electron cyclotron and lower hybrid electron heating,current drive,and energy confinement of stationary plasma on EAST.It further introduced an example of integrated "hybrid" operating scenario of interest to ITER and CFETR.  相似文献   

11.
Impurity is one of the key issues on a great impact to the quality of tokamak plasma.HL-2A is the first divertor tokamak in China. In this paper the experimental results are presented on impurity through the line emission measurement in the campaign in 2003 under the limiter and divertor configurations. The low-Z impurities such as carbon and oxygen are the most important components in the plasma, but their content are not so high to affect the discharge quality. The high-Z impurities such as copper and ferrum are not essential. The emission intensity of impurity is clearly decreased during the divertor configuration formed.  相似文献   

12.
The edge plasma code package SOLPS5.0 is employed to simulate the divertor power footprint widths of the experimental advanced superconducting tokamak(EAST)L-mode and ELM-free H-mode plasmas.The divertor power footprint widths,which consist of the scrape-off layer(SOL)widthλ_q and heat spreading 5,are important physical parameters for edge plasmas.In this work,a plasma current scan is implemented in the simulation to obtain the dependence of the divertor power footprint width on the plasma current I_p.Strong inverse scaling of the SOL width with I_p has been achieved for both L-mode and H-mode plasmas in the forms ofλ_(q,L-mode)=4.98×I_p~(-0.68)andλ_(q,H-mode)=1.86×I_p~(-1.08).Similar trends have also been demonstrated in the study of heat spreading with S_(L-mode)=1.95×I_p~(-0.542)and S_(H-mode)=0.756×I_p~(-0.872).In addition,studies on divertor peak heat load and the magnetic flux expansion factor show that both of them are proportional to plasma current.The simulation work here can act as a way to explore the power footprint widths of future tokamak fusion devices such as ITER and the China Fusion Engineering Test Reactor(CFETR).  相似文献   

13.
A two-point model is used to investigate the characteristics of scrape-off layer(SOL) plasma with the field line tracing method in the experimental advanced superconducting tokamak. The profiles of plasma density, temperature and particle flux on the divertor target calculated by the model are in reasonable agreement with experimental observation. Moreover, the profiles of plasma parameters on the divertor target strongly depend on the SOL magnetic topology or the equilibrium configuration from the modeling.  相似文献   

14.
In the 2016 EAST experimental campaign,a steady-state long-pulse H-mode discharge with an ITER-like tungsten divertor lasting longer than one minute has been obtained using only RF heating and current drive,through an integrated control of the wall conditioning,plasma configuration,divertor heat flux,particle exhaust,impurity management,and effective coupling of multiple RF heating and current drive sources at high injected power.The plasma current (Ip ~ 0.45 MA) was fully-noninductively driven (Vloop < 0.0 V) by a combination of ~2.5 MW LHW,~0.4 MW ECH and ~0.8 MW ICRF.This result demonstrates the progress of physics and technology studies on EAST,and will benefit the physics basis for steady state operation of ITER and CFETR.  相似文献   

15.
The ARIES-CS study has been launched with the goal of developing through physics and engineering optimization an attractive power plant concept based on a compact stellarator configuration. The study included an effort to characterize the divertor location and corresponding heat load distribution, and to develop a He-cooled divertor concept that could accommodate a heat flux of at least 10 MW/m2, and that would integrate well with the other power core components. This paper describes the design study of this divertor concept, which, although developed for a compact stellarator, is well suited for a tokamak configuration also.  相似文献   

16.
As a new diagnostic means, plasma-imaging system has been developed on the HL-2A tokamak, with a basic understanding of plasma discharge scenario of the entire torus, checking the plasma position and the clearance between the plasma and the first wall during discharge. The plasma imaging system consists of (1) color video camera, (2) observation window and turn mirror, (3) viewing & collecting optics, (4) video cable, (5) Video capture card as well as PC. This paper mainly describes the experimental arrangement, plasma imaging system and detailed part in the system, along with the experimental results. Real-time monitoring of plasma discharge process, particularly distinguishing limitor and divertor configuration, the imaging system has become key diagnostic means and laid the foundation for further physical experiment on the HL-2A tokamak.  相似文献   

17.
An infrared camera (IR) has been put into operation in the Experimental Advanced Superconducting Tokamak (EAST), which is used to measure the temperature distribution on the surface of lower divertor target plates. With a finite di®erence method, the heat flux onto the divertor target plates is calculated from the surface temperature profile. The high confinement mode (H-mode) with type-III edge localized modes (ELMs) has been obtained with about 1 MW lower-hybrid wave power on the EAST in the autumn experiment in 2010. The analyzed H-mode discharges were lower single null X-point diverted discharges with a density range of < ne > (1~ 4)x 1019 m-3. The surface temperature of the inner target plate increases with heating power. The peak temperature on the surface of target plates is lower than 200 oC with about 2.4 MW heating power. Comparison among the heat flux profiles occurring in di fferent phases in the same discharge has been erformed. It indicates that the heatflux profile obviously changes from the ohmic phase to the H-mode phase, and the full width at half maximum (FWHM) of the heat flux pro file is the narrowest during the ELM-free H-phase. On the outer target plate, the peak heat flux exceeds 2 MW/m2 during the ELMy H-mode phase, whereas it is only about 0.8 MW/m2 during the ELM-free phase in the same discharge.  相似文献   

18.
Plasma control system (PCS),mainly developed for real-time feedback control calculation,plays a significant part during normal discharges in a magnetic fusion device,while the tokamak simulation code (TSC) is a nonlinear numerical model that studies the time evolution of an axisymmetric magnetized tokamak plasma.The motivation to combine these two codes for an integrated simulation is specified by the facts that the control system module in TSC is relatively simple compared to PCS,and meanwhile,newly-implemented control algorithms in PCS,before applied to experimental validations,require numerical validations against a tokamak plasma simulator that TSC can act as.In this paper,details of establishment of the integrated simulation framework between the EAST PCS and TSC are generically presented,and the poloidal power supply model and data acquisition model that have been implemented in this framework are described as well.In addition,the correctness of data interactions among the EAST PCS,Simulink and TSC is clearly confirmed during an interface test,and in a simulation test,the RZIP control scheme in the EAST PCS is numerically validated using this simulation platform.  相似文献   

19.
The radial electric field in the edge plasma of small size divertor tokamak can be simulated by B2SOLPS0.5.2D fluid transport code. The simulation provides the follow results: (1) Switching on and off the part of the parallel plasma viscosity driven by parallel ion diamagnetic heat flux (Bekheit in J. Fusion Energ 27(4), 338–345, 2008; Schneider et al. in Nucl. Fusion 41:387, 2001) and Counter-NBI plasma heating change profile of radial electric field significantly. (2) Switching on and off the parallel plasma viscosity driven by parallel ion diamagnetic heat flux leads to the radial electric field is toroidal magnetic field dependence (3) For the case of counter-NBI plasma heating, the switching on and off the current driven by part parallel plasma viscosity depends on the ion diamagnetic heat flux leads to the ion poloidal velocity is toroidal magnetic field BT dependence. (4) The profile of the radial electric field in edge plasma of small size divertor tokamak is consistent with poloidal rotation velocity.  相似文献   

20.
Plasma discharge operation with lithium coating suggests that the lithium effectively control neutral particles in the plasma periphery, which can lead to improvement of plasma parameters. The effect of lithium coating on the large helical device (LHD) for a closed helical divertor configuration is discussed from viewpoints of neutral particle and impurity ion transport in the plasma periphery. It shows that the closed helical divertor configuration can enhance the neutral particle density in the divertor region, which is enough to achieve efficient particle control, and that it can effectively confine neutral lithium atoms near divertor plates. A one-dimensional impurity (lithium) ion transport analysis along magnetic field lines on divertor legs indicates that the friction force due to the plasma flow from the main plasma is dominant over the thermal force caused by the temperature gradient on the divertor legs, which prevents lithium ion contamination in the main plasma and excessive cooling of the plasma temperature in an ergodic layer. The analysis shows that the lithium coating is compatible with LHD plasma discharge operation for the closed helical divertor configuration.  相似文献   