首页 | 官方网站   微博 | 高级检索  
     


Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target
Authors:Lei LI  Le HAN  Pengfei ZI  Lei CAO  Tiejun XU  Nanyu MOU  Zhaoliang WANG  Lei YIN  Damao YAO
Abstract:The divertor target components for the Chinese fusion engineering test reactor (CFETR) and the future experimental advanced superconducting tokamak (EAST) need to remove a heat flux of up to ~20 MW m-2.In view of such a high heat flux removal requirement,this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology.Rectangular water-cooled channels with a special thermal transfer structure (TTS)are designed in the heat sink to improve the flat-tile divertor target's heat transfer performance(HTP).The parametric design and optimization methods are applied to study the influence of the TTS variation parameters,including height (H),width (W*),thickness (T),and spacing (L),on the HTP.The research results show that the flat-tile divertor target's HTP is sensitive to the TTS parameter changes,and the sensitivity is T > L > W* > H.The HTP first increases and then decreases with the increase of T,L,and W* and gradually increases with the increase of H.The optimal design parameters are as follows:H =5.5 mm,W* =25.8 mm,T =2.2 mm,and L =9.7 mm.The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method.A flat-tile divertor mock-up is developed according to the optimized parameters.In addition,high heat flux (HHF)tests are performed on an electron beam facility to further investigate the mock-up HTP.The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m-2 under the tungsten tile thickness<5 mm and the flow speed ≥7 m s-1.The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by ~ 13% and ~30% compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock,respectively.The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of 20 MW m-2 of heat load without visible deformation,damage,and HTP degradation.The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only ~930 ℃.The fiat-tile divertor target's HTP is greatly improved by the parametric design and optimization method,and is better than the ITER-like monoblock and the fiat-tile mock-up for the WEST divertor.This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors.
Keywords:CFETR  heat transfer performance  parametric design and optimization  HHF tests  flat-tile divertor target
本文献已被 万方数据 等数据库收录!
点击此处可从《等离子体科学和技术》浏览原始摘要信息
点击此处可从《等离子体科学和技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号