首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The present paper discusses (a) the analysis of a wire-on-tube condenser under varying operating conditions of free convection using FEM, and (b) experimental verification of the performance of two wire-on-tube condensers in a retrofitted domestic refrigerator using refrigerant R-134a. The study is motivated by the desire to investigate if the wire-on-tube condensers used in R-12 based refrigerators could be used in a modified refrigerator using R-134a refrigerant. Experiments were conducted in a climate chamber under controlled and varying ambient temperatures and mass flow rates to determine the locations where phase change occurs and the degree of subcooling achieved. In terms of initial and final phase change point locations the predicted results agree with the experimental results to within ±10%. The analysis and the experiments also lead to the information about the adequacy of the number of tubes for complete condensation of the refrigerant vapour under given operating conditions. The methodology can be used as a design tool for the design of wire-on-tube condenser of a small refrigerator as well as the suitability of specific decommissioned condensers for use in a retrofitted refrigerator. It also indicates that R-12 based refrigerators using wire-on-tube condensers retrofitted with R-134a compressor and refrigerant deserve and warrant further studies for adoption.  相似文献   

2.
This paper studies the effect of adding a phase change material (PCM) slab on the outside face of a refrigerator evaporator. A dynamic model of the vapour compression cycle including the presence of the phase change material and its experimental validation is presented. The simulation results of the system with PCM show that the addition of thermal inertia globally enhances heat transfer from the evaporator and allows a higher evaporating temperature, which increases the energy efficiency of the system. The energy stored in the PCM is yielded to the refrigerator cell during the off cycle and allows for several hours of continuous operation without power supply.  相似文献   

3.
The thermodynamic analysis of a V-type Stirling-cycle refrigerator is performed. The Stirling-cycle refrigerator consists of expansion and compression spaces, cooler, heater and regenerator, and divided into 14 fixed control volumes subjected to a periodic mass flow. The conservation of mass and energy equation are written for each control volume. A computer program is prepared in FORTRAN, and the basic equations are solved iteratively. The mass, temperature and density of working fluid in each control volume are calculated for a given charge pressure, engine speed, and fixed heater and cooler surface temperatures, and the results are obtained from a PC. The heat transfer coefficients are assumed constant. The work, instantaneous pressure and COP of the Stirling-cycle refrigerator are also calculated. The steady cyclic conditions are obtained for temperature after few cycles and the results are given by diagrams.  相似文献   

4.
In almost all domestic refrigerators–freezers all components are assembled in the same relative position since several years ago. It is also known that the condenser releases heat at high temperatures (first law of thermodynamics) as well as the compressor. This heat is rejected to the environment in almost all practical situations partially by natural air convection. However, part of it is due to thermal radiation that causes an overheating of the refrigerator–freezer surfaces adjacent to those equipments. As a consequence there are more heat gains to the refrigerator–freezer through these surfaces and hence higher air temperatures inside. This paper describes how a simple technique can be very useful in order to minimize that part of heat transfer by radiation. The improvement is achieved by placing a radiation shield – a sheet of aluminium foil – over the surfaces close to the condenser and the compressor. For validating this technique a refrigerator–freezer was monitored with thermocouples for the measurements of the inside air temperatures in two situations: with and without the radiation shield. Results show that with this practice the average inside air temperatures in the refrigerator–freezer could decrease to about 2 K. An available commercial code was used in order to simulate the air temperature distribution and air velocities inside the refrigerator cabinet in both situations. Results from the experimental apparatus and from simulations show that there is a good agreement between them which validates the experiments carried out.Also an available commercial code, the Fluent, was used to simulate the internal air temperature in both situations.  相似文献   

5.
The unsteady heat and mass transfer process during beef carcass chilling was modelled for a three-dimensional beef carcass geometry. A three-step method was used to simulate the simultaneous heat and mass transfer process in order to reduce the computational time. In the first step, a steady state simulation of the flow field was conducted. In the second step, the local heat and mass transfer coefficients were calculated. Finally, the third step consists of the simultaneous heat and mass transfer process simulation on the meat carcass only. A separate 1-D grid was used to calculate the moisture diffusion in the meat. The simulation of a 20-h chilling run takes 5 days on a 2.5 GHz Pentium 4 computer. The model allows calculating and predicting the heat load, temperatures, weight loss and water activity. Local variations in the heat and mass transfer coefficients, temperature and water activity were found around the beef carcass. The CFD model gives temperature predictions that agree with experimental data better than any previous model. The weight loss tends to be over-predicted probably due to neglecting the resistance caused by the fat cover.  相似文献   

6.
This is the second paper of a series that assesses the performance of a refrigeration system model by means of cycle parameters. In this case, the condensation temperature is the parameter to study and it is focused on fin and tube condensers. It also studies the influence of the heat transfer models on the estimation of this refrigeration cycle parameter and different correlations for the heat transfer coefficients have been implemented in order to characterise the heat transfer in the heat exchangers. The flow inside the heat exchangers is considered one-dimensional as in previous works. In the cycle definition, other submodels for all the cycle component have been taken into account to complete the system of equations that characterises the behaviour of the refrigeration cycle. This global system is solved by means of a Newton–Raphson algorithm and a known technique called SEWTLE is used to model the heat exchangers. Some experimental results are employed to compare the condensation temperatures provided by the numerical procedure and to evaluate the performance of each heat transfer coefficient. These experimental results correspond to an air-to-water heat pump and are obtained by using R-22 and R-290 as refrigerants.  相似文献   

7.
The authors developed a new air-supply system for improving the thermal uniformity and the cooling rate inside a fresh food cabinet of a household refrigerator. For these purposes, we added a blower and jet slots to a conventional cooled air supply system. The jet slots circulate the air inside the cabinet at a higher velocity to optimize airflow velocity and its distribution. The jet stirs the air inside the cabinet and improves thermal uniformity, which resulted in half the temperature deviation in the cabinet as that of the conventional systems. The jet also improves the heat transfer on the surface of foods. We achieved a four times higher cooling rate with the new system than that with the conventional ones. In order to cut down the development period, we applied computational fluid dynamics to study air distribution inside the cabinet with the new system. We also derived the model of the cooling process by the jet using theoretical and empirical equations and applied it to decide the jet velocity for the rapid cooling.  相似文献   

8.
Jet-refrigeration cycles seem to provide an interesting solution to the increasing interest in environment protection and the need for energy saving due to their low plant costs, reliability and possibility to use water as operating fluid. A steam/steam ejector cycle refrigerator is investigated introducing a two-stage ejector with annular primary at the second stage. The steady_state refrigerator, exchanging heat with the water streams at inlet fixed temperatures at the three shell and tube heat exchangers, evaporator, condenser and generator, is considered as an open system. Heat transfer irreversibilities in the heat exchangers and external friction losses in the water streams are considered, ignoring the internal pressure drop of the vapor. A simulation program numerically searches the maximum COP at given external inlet fluid temperatures as a function of mass flows, dimensions and temperature differences in the heat exchangers. The code gives the ejector and heat exchangers design parameters.  相似文献   

9.
This paper presents modeling and experimental analyses of evaporators in “in situ” frozen-food display cabinets at low temperatures in the supermarket industry. Extensive experiments were conducted to measure store and display cabinet relative humidities and temperatures, and pressures, temperatures and mass flow rates of the refrigerant. The mathematical model adopts various empirical correlations of heat transfer coefficients and frost properties in a fin-tube heat exchanger in order to investigate the influence of indoor conditions on the performance of the display cabinets. The model is validated with the experimental data of “in situ” cabinets. The model would be a good guide tool to the design engineers to evaluate the performance of supermarket display cabinet heat exchangers under various store conditions.  相似文献   

10.
Butter is a water-in-oil emulsion so its behaviour during freezing is very different from that of most food products, for which water forms a continuous phase. The release of latent heat during freezing is controlled as much by the rate of crystallization of water in each of the water droplets as by the rate of heat transfer. Measurements of the freezing of butter show that the release of latent heat from the freezing water depends on the degree of supercooling, which, in turn, depends on the cooling medium temperature, the size of the butter item, the packaging and the type of butter. Four modelling approaches were tested against the experimental data collected for a 25 kg block of butter. A “sensible heat only model” accurately predicted the butter temperature until temperatures at which water freezing becomes significant were reached. An “equilibrium thermal properties model” predicted a temperature plateau near the initial freezing point of the butter in a manner that was inconsistent with the measured data. A third model used a stochastic approach to ice nucleation based on supercooling using classical homogeneous nucleation theory. The predicted temperatures showed that supercooling-driven nucleation alone is not sufficient to predict the freezing behaviour of butter. A fourth approach took account of time-dependent nucleation and ice crystal growth kinetics using classical Avrami crystallization theory. The relationship between the ice crystal growth rate and the supersaturation was assumed to be linear. The model predicted the experimental data accurately, particularly by predicting the slow rebound in the temperature following supercooling that is found when freezing butter under some conditions.  相似文献   

11.
The performance of a thermoacoustic refrigerator subjected to variable loading was analyzed experimentally and the data were compared with those obtained using a computational model. The computational model relies on one-dimensional cross-section-averaged equations discretized using the network analogy. The thermoacoustic refrigerator was modeled by dividing it into 1 mm long slices in the direction of the acoustic axis. The hot heat exchanger of the thermoacoustic refrigerator was maintained at ambient temperature and the temperature of the cold heat exchanger was varied to achieve temperature differences of ΔT=0, 5 and 10 K along the stack. The cooling load was measured and calculated for these temperature differences while varying the driving frequency between 30 and 65 Hz. The contribution of the progressive and stationary waves and the losses on the thermoacoustic heat flow was computed and discussed.  相似文献   

12.
In this paper, we applied an Adaptive Neuro-Fuzzy Inference System (ANFIS) model for prediction of the heat transfer rate of the wire-on-tube type heat exchanger. Limited experimental data was used for training and testing ANFIS configuration with the help of hybrid learning algorithm consisting of backpropagation and least-squares estimation. The predicted values are found to be in good agreement with the actual values from the experiments with mean relative error less than 2.55%. Also, we compared the proposed ANFIS model to an ANN approach. Results show that the ANFIS model has more accuracy in comparison to ANN approach. Therefore, we can use ANFIS model to predict the performances of thermal systems in engineering applications, such as modeling heat exchangers for heat transfer analysis.  相似文献   

13.
This study presents a first-principles mathematical model developed to investigate the thermal behavior of a plate-type, roll-bond evaporator. The refrigerated cabinet was also taken into account in order to supply the proper boundary conditions to the evaporator model. The mathematical model was based on the mass, momentum and energy conservation principles applied to each of the following domains: (i) refrigerant flow through the evaporator channels; (ii) heat diffusion in the evaporator plate; and (iii) heat transmission to the refrigerated cabinet. Empirical correlations were also required to estimate the shear stresses, and the internal and external heat transfer rates. The governing partial differential equations were discretized through the finite-volume approach and the resulting set of algebraic equations was solved by successive iterations. Validation of the model against experimental steady-state data showed a reasonable level of agreement: the cabinet air temperature and the evaporator cooling capacity were predicted within error bands of ±1.5 °C and ±6%, respectively.  相似文献   

14.
In a refrigerant compressor, improvement in performance such as reduction of various electrical and mechanical losses, reduction of gas leakage, better lubrication, reduction of suction gas heating etc. can be achieved by maintaining a low temperature rise inside the compressor. Proper selection and location of an internal over load protector relay, estimation of heat transfer coefficient and winding insulation coefficient are also vital in enhancing the performance. In this context it is necessary to understand the temperature distribution inside a compressor for an optimal design. In this paper, a numerical model has been created and a heat transfer analysis for a hermetically sealed reciprocating refrigerant compressor is presented. The temperature distribution inside the compressor has been obtained taking into consideration the various heat sources and sinks and compared with experimental results. The maximum temperature was observed at the rotor which was 427.5 K. The deviation of the predicted rotor temperature from that of experimental value is 5.5% only. A good agreement was found between experimental results and that predicted in the numerical analysis.  相似文献   

15.
The energy consumption of a household refrigerator is closely related to the distributions of temperature inside its compartments. Since, such distributions are dependent on the chilled air circulating inside the refrigerator, its energy consumption can be reduced and its efficiency improved through optimization of the air flow fields inside the compartments. In this work, particle image velocimetry (PIV) was used to measure velocity fields inside the freezer compartment of a commercial top-mount no-frost refrigerator at two critical vertical sections at three different temperatures levels. To perform the tests, a commercial unit was equipped with two specially constructed insulated windows which enabled clear visualization of the flow field under real operating conditions. The results show that significant changes in the air flow distribution occur when the temperature is reduced.  相似文献   

16.
This paper reports heat transfer results obtained during condensation of refrigerant propane inside a minichannel aluminium heat exchanger vertically mounted in an experimental setup simulating a water-to-water heat pump. The condenser was constructed of multiport minichannel aluminium tubes assembled as a shell-and-tube heat exchanger. Propane vapour entered the condenser tubes via the top end and exited sub-cooled from the bottom. Coolant water flowed upward on the shell-side. The heat transfer areas of the tube-side and the shell-side of the condenser were 0.941 m2 and 0.985 m2, respectively. The heat transfer rate between the two fluids was controlled by varying the evaporation temperature while the condensation temperature was fixed. The applied heat transfer rate was within 3900–9500 W for all tests. Experiments were performed at constant condensing temperatures of 30 °C, 40 °C and 50 °C, respectively. The cooling water flow rate was maintained at 11.90 l min−1 for all tests. De-superheating length, two-phase length, sub-cooling length, local heat transfer coefficients and average heat transfer coefficients of the condenser were calculated. The experimental heat transfer coefficients were compared with predictions from correlations found in the literature. The experimental heat transfer coefficients in the different regions were higher than those predicted by the available correlations.  相似文献   

17.
A survey was carried out in France from April to June 1999. Temperatures were recorded at three levels (top, middle and bottom) of the refrigerator compartment using a data logger. A questionnaire was filled in, enabling the following information to be obtained: characteristics of the family, characteristics of the refrigerator and the use conditions. One hundred and forty-three domestic refrigerators were surveyed, but due to various technical problems, only 119 sets of recorded temperatures were exploitable. The temperatures of the surveyed refrigerators were: average 6.6 °C, minimum 0.9 °C and maximum 11.4 °C. Statistical analysis such as clustering and segmentation were used. It was found that the heterogeneousness of temperature inside each refrigerator seems to be dependent on the type. This study shows the influence of the use conditions on the temperature. No one factor exerts a single direct effect; a combination of the effects of all factors is observed.  相似文献   

18.
This paper is the second paper out of two which present the development of a dynamic model for single-effect LiBr/water absorption chillers. The first part describes the model in detail with respect to the heat and mass balances as well as the dynamic terms. This second part presents a more detailed investigation of the model performance, including performance analysis, sensitivity checks and a comparison to experimental data. General model functionality is demonstrated.A sensitivity analysis gives results which agree very well to fundamental expectations: it shows that an increase in both external and internal thermal mass results in a slower response to the step change but also in smaller heat flow oscillations during the transient period. Also, the thermal mass has been found to influence the heat flow transients more significantly if allocated internally. The time shift in the solution cycle has been found to influence both the time to reach steady-state and the transients and oscillations of the heat flow. A smaller time shift leads to significantly faster response.A comparison with experimental data shows that the dynamic agreement between experiment and simulation is very good with dynamic temperature deviations between 10 and 25 s. The total time to achieve a new steady-state in hot water temperature after a 10 K input temperature step amounts to approximately 15 min. Compared to this, the present dynamic deviations are in the magnitude of approximately 1–3%.  相似文献   

19.
In this paper, a transient model of a silica gel–water adsorption chiller, which is developed in Shanghai Jiao Tong University (SJTU), is developed in order to simulate the evaporating, condensing, and adsorption temperature. Furthermore, this model is verified by a series of experiments. The theoretical studies and experimental data show that the coefficient of performance (COP) is influenced significantly by the variation rates of the heat source temperatures. The results also show that when this chiller is driven by solar energy, a buffer tank should be adopted in the system in order to get better performance when solar insolation is low, and should not be utilized when solar insolation is high, otherwise low COP will be gotten for the reason of the consumption of high electric energy.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号