首页 | 官方网站   微博 | 高级检索  
     


Measurements of the air flow field in the freezer compartment of a top-mount no-frost refrigerator: the effect of temperature
Authors:VT Lacerda  C Melo  JR Barbosa  Jr  POO Duarte
Affiliation:aDepartment of Mechanical Engineering, Federal University of Santa Catarina, 88040-900 Florianópolis, SC, Brazil;bMultibrás Eletrodomésticos S.A., Whirlpool Corporation, Rua Dona Francisca, 7200, 89219-900 Joinville, SC, Brazil
Abstract:The energy consumption of a household refrigerator is closely related to the distributions of temperature inside its compartments. Since, such distributions are dependent on the chilled air circulating inside the refrigerator, its energy consumption can be reduced and its efficiency improved through optimization of the air flow fields inside the compartments. In this work, particle image velocimetry (PIV) was used to measure velocity fields inside the freezer compartment of a commercial top-mount no-frost refrigerator at two critical vertical sections at three different temperatures levels. To perform the tests, a commercial unit was equipped with two specially constructed insulated windows which enabled clear visualization of the flow field under real operating conditions. The results show that significant changes in the air flow distribution occur when the temperature is reduced.
Keywords:Domestic refrigerator  Refrigerator-freezer  Process  Speed  AirMots clé  s: Refrig´  rateur domestique  Refrigé  rateur-congé  lateur  Procé      Vitesse  Air
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号