1.
目的探讨128层螺旋CT低剂量高分辨扫描技术在肺间质病变观察中的临床价值。方法 92例引起肺间质病变的结缔组织疾病患者,采用A剂量(管电压140kV,管电流250mAs)、B剂量(管电压140kV,管电流150mAs)和C剂量(管电压140kV,管电流75mAs)分别对感兴趣区进行高分辨CT扫描;探测器宽度10mm,层厚0.625mm轴扫;病变观察指标包括磨玻璃病变、小叶间隔、小叶内隔、支气管血管束、胸膜下线、网状影、蜂窝状影、小结节。通过卡方检验分析低剂量高分辨CT扫描总体病变指标和单项病变指标的显出率。结果①A剂量与B剂量总体病变指标进行两两比较,差异性无统计学意义(P>0.025);A剂量与C剂量比较差异有统计学意义(P<0.025)。另A剂量与B剂量单项病变指标之间进行比较差异无统计学意义(P>0.025);②A剂量与B剂量、C剂量分别进行单项病变指标比较,显示无差异(P>0.025),尤其是增厚支气管血管束、网格状影和小结节在三种剂量无明显差异;区别略明显的是磨玻璃病变、胸膜下线和增厚小叶内隔,以C剂量显出率最低。结论本研究表明低剂量高分辨CT扫描(140kV,150mAs)在肺间质病变的观察诊断中是可行的,可以降低患者40%的辐射量,可实现肺高分辨CT扫描的同时降低患者的辐射剂量。  相似文献   

2.
肺结节模型低剂量扫描及薄层重建对结节CT值的影响   总被引:1,自引:0,他引:1  
目的 探讨低剂量CT扫描及薄层重建对肺结节CT值的影响.方法 选用CT值为-900 HU的塑料模拟肺基底,用直径不同的球体模拟肺结节(直径分别为20.0、10.0、5.0 mm及2.5 mm);每种直径的结节分别由3种不同材料(其CT值分别为:100 HU、60 HU及-100 HU).肺基底中央固定由上述3种材料分别制成的3个圆柱体(半径为10.0 mm、长为50.0 mm),其CT值作为每种材料的准确CT值.扫描参数:管电压120 kV、层厚5.0 mm、扫描间隔5.0 mm、螺距0.938:1、扫描时间0.8 s/r,改变管电流(20~120 mA,间隔10 mA)重复扫描肺结节模型.重建层厚0.625 mm,重建间隔0.625 mm,标准重建算法.在工作站上测量重建层厚为5 mm及0.625 mm条件下肺结节的CT值及SD值(直径为2.5 mm结节未测量).统计分析不同扫描剂量、不同重建层厚对结节CT值及标准差(SD)值的影响. 结果 ①在层厚为0.625 mm时:直径为5.0 mm、密度为-100 HU的结节在不同管电流条件下测得CT值之间有明显统计学差异(P=0.01<0.05);其它结节在不同管电流条件下测得CT值无显著性差异(P值均>0.05);所有结节的SD值在不同管电流条件下有明显的统计学差异(P值均<0.05),且管电流越小,SD越大.②在层厚为5.0 mm时:相同密度结节(直径20.0 mm、10.0 mm、5.0 mm)CT值与标准CT值有明显的统计学差异(P值均<0.05);采用薄层重建(层厚0.625 mm)时:直径为20.0 mm结节的CT值与标准CT值之间无明显的统计学差异(P>0.05);直径为10.0 mm及5.0 mm结节的CT值与标准CT值仍有显著性差异(P<0.05),但其CT值与标准CT值间的差值明显减小.结论 在低剂量条件下扫描可以比较准确地测得肺结节的CT值(直径较小、密度较低的结节不能准确测得结节CT值),同时随着剂量的减低噪声明显增大;采用薄层重建能提高小结节CT值测量的准确性.  相似文献   

3.
目的 评价应用不同水平iDose4迭代重建技术在低剂量HRCT中评估肺纯磨玻璃密度结节(pGGN)的可行性.方法 应用Philips Brilliance 128排螺旋CT在5种不同的剂量水平(管电压120 kV不变,管电流200 mAs、100 mAs、50 mAs、25 mAs、10 mAs)下对含有9个5~12 mm的pGGN的仿真胸部体模进行HRCT扫描,并分别采用传统的滤波反投影(FBP)和iDose4迭代重建技术(水平分别选4和7)进行数据重建.由两名有经验的影像科医师采用盲法对不同剂量水平、不同重建技术下显示的pGGN的图像质量进行主观评价,并用Kappa检验评价观察者间的一致性,测量并比较每次扫描的有效辐射剂量(ED)和图像噪声(MSD).结果 对不同剂量水平、不同重建技术下显示的pGGN的图像质量进行主观评价,两名观察者间的一致性中等或较好(K>0.4).SD值在不同管电流条件下差异有显著统计学意义(P值均<0.05),且管电流越小,SD值越大.在同一剂量水平下,SD值在不同重建算法间差异有显著统计学意义(P值均<0.05),iDose4迭代重建技术可以明显降低SD值,且iDose4所选的水平越高,SD值越小.在管电流低至10 mAs水平时,各组pGGN均能显示,结合iDose4迭代重建技术后图像质量明显改善.25 mAs采用iDose-4/7重建后图像的肺结节可见度评分优于50 mAs FBP重建后的图像(P<0.001).结论 与传统的FBP相比,iDose4迭代重建技术可以明显的改善噪声,且不同的iDose水平降低噪声的能力不一.128排螺旋CT实验条件下10 mAs可以检出≥5 mm的pGGN,结合iDose4迭代重建技术后图像质量明显改善,有利于结节边缘情况的显示.  相似文献   

4.
目的 探讨低剂量64层CT测定冠状动脉钙化积分的可重复性.方法 43例冠状动脉钙化的患者连续进行2次64层螺旋CT扫描,管电流分别为100 mAs和55 mAs,其余参数不变,由2名放射科医生测定钙化积分,计算前后2次扫描差值;同时测量升主动脉的CT值的均数及标准差.结果 2次扫描在观察者和观察者内部差值的绝对值多数在50以内(分别为81.4%和86.5%).低剂量扫描对不同测量者无明显统计学差异(P=0.883和0.952);取平方根转换后均具有明显相关(r均为0.998).采用管电流55 mAs,所测均数与2倍标准差之和低于130 HU,可将辐射剂量降低0.6 mSv.结论 低剂量前门控64层CT钙化积分扫描在降低辐射剂量的同时,图像满足测量需要,具有较高的可重复性.  相似文献   

5.
目的 探讨64层螺旋CT牙齿低剂量扫描的可行性及合理性.方法 连续选取360例行颌面部CT扫描的受检者,随机均分为上颌组和下颌组.设置不同kV(120,100,80)、不同mAs(200,100,50,30,20,10)组成18组扫描参数,对照组为120 kV、200 mAs.选出图像质量符合临床诊断要求的最低有效剂量对应的扫描参数kV、mAs值.结果 80 kV、20 mAs组对应的有效剂量为0.011 mSv,较对照组降低了96.3%,两者差异有统计学意义(P<0.05),而图像质量无明显差异.结论 适当的同时降低管电压和管电流是一种切实可行的降低辐射剂量的牙齿扫描方法.  相似文献   

6.
目的 探讨低剂量64层螺旋CT测定冠状动脉钙化积分的准确性。方法 2006年8月至2009年9月间对43名冠状动脉钙化的患者连续进行2次64层螺旋CT扫描,管电流时间积分别为常规剂量(100 mAs)和低剂量(55 mAs),其余参数不变,由2名放射科副主任医师测定钙化积分并测量升主动脉CT值的均数及标准差。结果 低剂量与常规剂量钙化总积分和独立血管钙化积分取平方根转换后均直线相关(r =0.998、0.997)。低剂量管电流时间积所测升主动脉根部的CT值的均数与2倍标准差之和小于130 HU,可满足所要求的信噪比,与常规剂量扫描辐射剂量(1.32±0.08)mSv相比较,低剂量扫描有效剂量降低0.6 mSv(P <0.05)。结论 低剂量前瞻性心电门控64层MDCT钙化积分扫描图像能满足测量需要,测量结果具有较高的准确性。  相似文献   

7.
目的探讨低剂量及常规剂量螺旋CT扫描在检出磨玻璃密度肺结节(ground-glass nodule,GGN)的数目、边缘、内部结构与周边结构是否在统计学上存在显著差异。方法对经常规剂量(200mA)与层厚(5mm)螺旋CT扫描发现GGN患者56例同时行肺部低剂量(30mA)螺旋CT扫描,所得图像分别重建2mm、1mm,并按结节直径5mm,5~10mm,10mm不同大小分组,记录结节数目、边缘、内部特征以及周边结构等。结果低剂量与常规剂量螺旋CT扫描在检出GGN的数目、边缘、内部结构与周边结构无统计学意义。结论30mA低剂量螺旋CT扫描及层厚2mm可对GGN作出较好的判断,值得在早期肺癌筛查中应用。  相似文献   

8.
目的 探讨64层CT自动管电流调节技术(ATCM)结合低电压在幼儿胸部低剂量扫描中的应用价值.方法 搜集行64层CT ATCM胸部扫描的幼儿(≤2岁)48例,其中A组(管电压100 kV)30例,B组(管电压80kV) 18例;并与既往采用固定管电流条件下的低剂量扫描数据进行对比分析,对照组C组(100 kV/60 mAs)30例;其余扫描参数一致.记录每次扫描的平均管电流(mAs)、CT容积剂量指数(CTDIvol)、剂量长度值(DLP),计算出有效剂量(ED)及剂量减低比值(DR),并比较3组的剂量及图像质量.结果 A组CTDIvol为(1.11±0.19)mGy,B组CTDIvol为(0.99 ±0.11)mGy,C组CTDIvol为(2.38±0.00) mGy;3组数据两两比较差异均有统计学意义(P<0.05).A组相对C组DR约51.07%,B组相对C组DR降低约58.20%.3组图像质量均满足诊断要求,差异无统计学意义(P=0.50).结论 低电压联合ATCM技术在幼儿胸部扫描中可以广泛应用,能够有效降低辐射剂量且不影响图像质量.  相似文献   

9.
多层螺旋CT肺部低剂量与常规剂量检查的放射剂量评估   总被引:19,自引:1,他引:18  
目的比较多层螺旋CT肺部低剂量与常规剂量检查的X线辐射剂量,为低剂量多层螺旋CT普查早期肺癌提供剂量参数. 资料与方法肺部低剂量与常规剂量多层螺旋CT扫描共54例.其中,低剂量扫描24例,扫描参数为:120 kV,20 mAs,准直器4×5 mm,重建层厚8 mm,床速30 mm/周,螺距为7,扫描时间0.5 s/周;常规剂量扫描30例,扫描参数为:120 kV,90 mAs,准直器4×5 mm,重建层厚8 mm,床速30 mm/周,螺距为7,扫描时间0.5 s/周.观察并计算两种扫描剂量的权重CT剂量指数(CTDIw),有效mAs,总mAs,剂量长度乘积(DLP)及有效辐射剂量. 结果肺部低剂量扫描的CTDIw为1.38 mGy,是常规剂量扫描(6.21 mGy)的22.2%;低剂量扫描的DLP为44 mGy*cm,明显低于常规剂量扫描的189 mGy*cm(P<0.01);低剂量扫描的总mAs为459,是常规剂量扫描(1 308)的35.1%;低剂量扫描的X线最大有效辐射剂量为0.9 mSv,明显低于常规剂量扫描的4.2 mSv(P<0.01). 结论多层螺旋CT肺部低剂量扫描(20 mAs)的有效辐射剂量为常规剂量扫描的21.4%,适用于高危人群普查早期肺癌.  相似文献   

10.
目的 分析胸部低剂量CT扫描图像噪声与伪影的影响因素及分布特点.方法 应用组织等效胸部模型置于Philips Brilliance 64层CT机以常规剂量(管电压120 kV,管电流250 mAs)和低剂量(管电压120 kV,管电流50、30和21 mAs)分别扫描,测量、记录模型各部位CT值、CT值噪声标准差(SO),分别行方差分析.对200例肺结节患者以30或21 mAs剂量组行小范围低剂量扫描,通过卡方检验分析不同剂量扫描影像噪声和伪影严重程度与患者性别、体型的关系及在肺部的分布特点.结果 不同扫描剂量条件下测量模型各部位CT值差异均无统计学意义:肺-777.3~-758.2 HU(F=0.992,P>0.05),胸壁107.9~111.3 HU(F=2.044,P>0.05),椎骨835.6~875.3 HU(F=1.453,P>0.05);而CT值SD差异有统计学意义:肺9.5~29.0 HU(F=108.7,P<0.01),胸壁10.1~32.4 (F=84.3,P<0.01),椎骨19.2~57.1 HU(F=30.6,P<0.01),且随电流降低而增加.临床患者低剂量扫描显示,不同性别组图像噪声和伪影严重程度(男性无或轻微者74例,严重者17例;女性无或轻微者81例,严重者28例)差异无统计学意义(X~2=2.294,P>0.05),不同体型组的体质量指数[(BMI)<18.5组无或轻微者29例,严重者2例;18.5≤BMI<24.0组无或轻微者120例,严重者13例;BMI≥24.0组无或轻微者6例,严重者30例]差异有统计学意义(X~2=128.274,P<0.01).低剂量扫描图像的噪声和伪影在上肺野(无或轻微者80例,严重者38例;X~2=18.918,P<0.01)、肺野后部(无或轻微者89例,严重者33例;X~2=6.760,P<0.05)较严重.结论 低剂量CT扫描图像噪声增加,噪声和伪影在肺野后、上部较严重,可能和骨骼分布有关.应根据受检者BMI调整扫描方案(mAs值),做到扫描方案个体化.  相似文献   

11.
多层CT螺距与辐射剂量的关系探讨   总被引:9,自引:1,他引:8       下载免费PDF全文
目的 探讨多层螺旋CT的扫描参数螺距的变化对辐射剂量的影响.方法 对于LightSpeed 16层螺旋CT和Sensation 16层和64层螺旋CT,将长杆电离室分别置于16 mm剂量体模的5个孔中,选用不同的螺距进行扫描并测量辐射剂量.结果 3种机型轴扫和螺旋扫描的CTDIvol分别为:(1)对于lightSpeed 16层螺旋CT,在轴扫及螺距分别为0.562、0.938,1.75时,分别等于28.9、51.4、30.8,16.5;(2)对于Sensation16层螺旋CT,在轴扫及螺距分别为0.5,1、1.5时,分别等于41.2、40.3、41.5,43.2;(3)对于Sensation64层螺旋CT,在轴扫及螺距分别为0.5,1.1.5时,分别等于41.2、40.3、41.5,43.2.结论 对于LightSpeed 16层螺旋CT,随着螺距的增加,辐射剂量降低,为保持恒定的图像质量,必须增大mAs作为补偿;Sensation 16层和64层螺旋CT,因采用了mAs自动调整技术,在不同的螺距下辐射剂量相同,图像质量稳定.日常操作中当螺距改变时,应根据不同机型来确定调整管电流的方法.  相似文献   

12.
汤振华 《医学影像学杂志》2012,22(7):1074-1075,1078
目的探讨64层螺旋CT低剂量扫描在眶区外伤中的应用价值。方法收集180例眶区外伤患者,随机分为两组,A组90位患者行眶区常规剂量(115mAs)扫描,B组90位患者在其他参数不变的情况下,行低剂量(40mAs)扫描,比较常规剂量扫描与低剂量扫描的辐射剂量及图像质量。结果低剂量(40mAs)的辐射剂量明显低于常规剂量,低剂量组与常规剂量组间的CTDIvol、DLP值比较均有明显统计学意义(P<0.01)。结论眶区外伤低剂量扫描不仅有效降低辐射剂量,而且图像质量满足诊断需求。  相似文献   

13.
OBJECTIVES: The accuracy of automated volumetry for pulmonary nodules in a phantom using different CT scanner technologies from single-slice spiral CT (SSCT) to 64-slice multidetector-row CT (MDCT) was compared. MATERIALS AND METHODS: A lung phantom with 5 different categories of pulmonary nodules was scanned using a single-slice spiral CT, a 4-slice MDCT, a 16-slice MDCT and a 64-slice MDCT. Each category comprised of 7-9 nodules each (total n = 40) with different known volumes. Standard dose and low dose protocols were performed using thin and thick collimation. Image data were reconstructed at the thinnest slice thickness. Data sets were analyzed with a dedicated volumetry software. Volumes of all nodules were calculated and compared. RESULTS: Mean absolute percentage error (APE) for all nodules was 8.65% (+/-7.29%) for the SSCT, 10.26% (+/-8.25%) for the 4-slice MDCT, 8.19% (+/-7.57%) for the 16-slice MDCT and 7.89% (+/-7.39%) for the 64-slice MDCT. There was statistically significant influence of the scanner type, protocol, anatomic location, and nodule volume on APE, but overall, APEs were comparable. CONCLUSION: Computer-aided volumetry showed accurate measurements in all tested scanner types. This finding has important implications for nodule assessment and follow-up.  相似文献   

14.
目的 探讨多层螺旋CT低剂量扫描在新生儿缺氧缺血性脑病(HIE)中的应用和防护价值.方法 前瞻性选取临床拟诊HIE 60例,随机等分成两组.扫描参数:管电压120 kV,层厚、层间距6 mm,管电流常规剂量组250 mAs、低剂量组50 mAs行全颅脑扫描.对比两种剂量扫描产生的加权CT剂量指数(CTDIw)、全头颅扫描剂量长度乘积(DLP);图像噪声的比较采用模拟儿童头颅的水模扫描,计算并比较两种剂量下的CT值均数与标准差;盲式评判两组扫描剂量的图像质量.结果 ①低剂量扫描组的mAs、CTDIw和DLP仅为常规剂量组的20%;②低剂量组水模噪声较常规剂量组大,两者差异有统计学意义(t=34.533,P<0.01).③低剂量组图像质量以较好为主,较常规剂量组稍差,但未出现差级图像,不影响HIE诊断.结论 低剂量CT扫描在HIE诊断中的应用是完全可行的,既能明确诊断又能有效地保护新生儿,符合医用辐射防护最优化原则.  相似文献   

15.
64层螺旋CT的层敏感度曲线测试   总被引:7,自引:0,他引:7  
目的 测试和评价64层螺旋CT的层敏感度曲线(SSP)及有效层厚半高宽(FWHM)。方法 对Somatom Sensation 64层螺旋CT,使用临床常用的腹部螺旋扫描模式和CT质控delta(8)体模,分别以螺距(pitch)=0.50、0.75、1.00、1.25、1.50,重建层厚0.6mm(标称值)进行扫描和重建。对于pitch=1.00,再分别以层厚1.0、1.5mm进行重建。然后测试各种情况的SSP和有效层厚。结果 对于标称层厚0.6mm,不同pitch时测试的有效层厚分别为0.67、0.67、0.66、0.69、0.69mm;pitch=1.00时,标称层厚0.6、1.0、1.5mm的有效层厚分别为0.66、1.06、1.52mm。有效层厚均略大于标称层厚,但与标称层厚相比均不超过0.1mm。测试的SSP形状近似钟形,左右分布基本对称,没有延伸较长的尾部;随着重组层厚的增加,SSP逐渐变平阔;当pitch改变时,SSP变化轻微。结论 对于Sensation64层螺旋CT,pitch的变化对SSP、有效层厚和z轴空间分辨率的影响很小。这一结论有助于临床应用中优化CT扫描方案。  相似文献   

16.
RATIONALE AND OBJECTIVES: We sought to compare coronary artery calcium (CAC) scores, the variability and radiation doses on 64- and 16-slice computed tomography (CT) scanners by both prospective electrocardiographically (ECG)-triggered and retrospective ECG-gated scans. MATERIALS AND METHODS: Coronary artery models (n = 3) with different plaque CT densities (approximately 240 Hounsfield units [HU], approximately 600 HU, and approximately 1000 HU) of four sizes (1, 3, 5, and 10 mm in length) on a cardiac phantom were scanned three times in five heart rate sequences. The tube current-time products were set to almost the same on all four protocols (32.7 mAs for 64-slice prospective and retrospective scans, 33.3 mAs for 16-slice prospective and retrospective scans). Slice thickness was set to 2.5 mm to keep the radiation dose low. Overlapping reconstruction with a 1.25-mm increment was applied on the retrospective ECG-gated scan. RESULTS: The CAC scores were not different between the four protocols (one-factor analysis of variance: Agatston, P = .32; volume, P = .19; and mass, P = .09). Two-factor factorial analysis of variance test revealed that the interscan variability was different between protocols (P < .01) and scoring algorithms (P < .01). The average variability of Agatston/volume/mass scoring and effective doses were as follows: 64-slice prospective scan: 16%/15%/11% and 0.5 mSv; 64-slice retrospective scan: 11%/11%/8% and 3.7 mSv; 16-slice prospective scan: 20%/18%/13% and 0.6 mSv; and 16-slice retrospective scan: 16%/15%/11% and 2.9 to 3.5 mSv (depending on the pitch). CONCLUSION: Retrospective ECG-gated 64-slice CT showed the lowest variability. Prospective ECG-triggered 64-slice CT, with low radiation dose, shows low variability on CAC scoring comparable to retrospective ECG-gated 16-slice CT.  相似文献   

17.
低剂量CT扫描结合迭代算法重建行颞骨成像   总被引:1,自引:0,他引:1       下载免费PDF全文
目的:探讨颞骨低剂量CT扫描结合迭代算法(iDose 3)行颞骨成像的可行性及其最佳参数。方法:以成年尸头为研究对象,应用飞利浦256层CT,采用螺旋扫描模式,分别在电压120 kV、100 kV和80 kV时用不同的管电流时间乘积进行颞骨扫描,从250 mAs 开始,间隔30 mAs 逐次降低,直至图像较差不能满足诊断时终止扫描,重建算法采用iDose level 3,滤过函数Y-sharp(C)。两位医生采用5分制评分标准对16个解剖结构进行评估。比较所有图像的图像质量及辐射剂量。结果:“100 kV+70 mAs+iDose level 3+Y-sharp(C)”的成像组合是良好显示解剖结构的最低剂量组合,有效剂量约0.15 mSv。结论:颞骨低剂量扫描切实可行,“100 kV+70 mAs+iDose level 3+ Y-sharp(C)”是最低剂量扫描方案。  相似文献   

18.
肺部低剂量螺旋CT放射剂量的研究   总被引:11,自引:5,他引:6  
目的 :评价低剂量与常规剂量螺旋CT扫描的X线放射剂量比。方法 :对肺内结节用 2 0 0mAs行常规剂量螺旋CT扫描 ,扫描参数为 :12 0kV ,层厚 10mm ,扫描间隔 10mm ,螺距 1 5。选取不同层厚 (5mm、10mm)分别用 2 0 0mA、4 0mA、30mA、2 0mA、10mA扫描 ,记录各组每次扫描的单次CT剂量加权指数CTDIw(mGy)及mAs。对所有数据进行统计学处理 ,P <0 0 5时差异有统计学意义。结果 :2 0 0mA常规剂量组之CTDIW及毫安秒值与低剂量各组 (40mA、30mA、2 0、10mA)值比较差异有统计学意义 (P <0 0 5 ) ;以 2 0 0mAs常规剂量为标准 ,其余低剂量组 4 0mA ,30mA ,2 0mA ,10mA毫安秒及CTDIw分别降低了 80 %、90 %、95 %。结论 :用 2 0mAs低剂量螺旋CT扫描毫安秒及CTDIW仅仅相当于用 2 0 0mAs的 1/10 ,辐射剂量降低了 90 %。 2 0mA是肺部扫描的最佳剂量 ,具有辐射量小、敏感性强、性价比高的特点 ,值得推广应用。  相似文献   

19.
The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 × 1.2mm), 50 mAs (collimation 20 × 1.2 and 64 × 0.6mm) and 80 mAs (20 × 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 × 1.2 and 64 × 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 × 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 × 1.2 mm) collimation.  相似文献   