1.
This study presents an experimental investigation of pressure drop in the evaporators and the riser of an advanced thermosyphon loop. The thermosyphon was designed for the cooling of three parallel high heat flux electronic components. The tested evaporators were made from small blocks of copper in which 7, 5, 4, 3, 2, 1 vertical channels with the diameters of 1.1, 1.5, 1.9, 2.5, 3.5 and 6 mm, respectively, and a length of 14.6 mm were drilled. Tests were done with isobutane at heat fluxes ranging between 22.4 and 303 kW/m2. For prediction of the pressure drop, in the riser, different combinations of frictional pressure drop and void fraction correlations were tested. Regarding the evaporator a simple correlation based on a homogeneous model [M.B. Bowers, I. Mudawar, Two-phase electronic cooling using mini-channel and macro-channel heat-sinks—part II, flow rate and pressure drop constraints, ASME J Electron Packaging 116 (1994) 298–305. [1]] has been used to predict the pressure drop.  相似文献   

2.
The development of an absorption based miniature heat pump system is motivated by the need for removal of increasing rates of heat from high performance electronic chips such as microprocessors. The goal of the present study is to keep the chip temperature near ambient temperature, while removing 100 W of heat load. Water/LiBr pair is used as the working fluid. A novel dual micro-channel array evaporator is adopted, which reduces both the mass flux through each micro-channel, as well as the channel length, thus reducing the pressure drop. Micro-channel arrays for the desorber and condenser are placed in intimate communication with each other using a hydrophobic membrane. This acts as a common interface between the desorber and the condenser to separate the water vapor from LiBr solution. The escaped water vapor is immediately cooled and condensed at the condenser side. For direct air cooling of condenser and absorber, offset strip fin arrays are used. The performance of the components and the entire system is numerically evaluated and discussed.  相似文献   

3.
Micro heat pumps, with dimensions in the order of centimetres, may in the future be utilised for the heating and/or cooling of buildings, vehicles, clothing, and other products or applications. A number of issues have yet to be solved, including the construction of a microscale compressor, and determination of micro heat exchanger heat transfer capacities. Test samples of micro heat exchangers and a corresponding test apparatus have been built. Some two-phase experiments with propane (R-290) as refrigerant have been conducted. Preliminary results for a micro condenser with 0.5 mm wide trapezoidal channels of 25 mm length showed that a heat flux of up to 135 kW/m2, based on the refrigerant-side area, was attainable. The corresponding overall heat transfer coefficient was 10 kW/(m2 K), with a refrigerant mass flux of 165 kg/(m2 s) and a refrigerant-side pressure drop of 180 kPa/m.  相似文献   

4.
Experimental investigation on R134a vapour ejector refrigeration system   总被引:6,自引:1,他引:5  
The experimental investigation of the performance of a vapour ejector refrigeration system is described. The system uses R134a as working fluid and has a rated cooling capacity of 0.5 kW. The influence of generator, evaporator and condenser temperatures on the system performance is studied. This kind of system can be operated with low grade thermal energy such as solar energy, waste heat, etc. The operating conditions are chosen accordingly as, generator temperature between 338 K and 363 K, condenser temperature between 299 K and 310.5 K, and evaporator temperature between 275 K and 285.5 K. Six configurations of ejectors of different geometrical dimensions are selected for the parametric study. The performance of the refrigeration system at different operating temperatures is presented.  相似文献   

5.
This paper presents a steady-state model for predicting the performance of vapour-compression liquid chillers over a wide range of operating conditions. The model overcomes the idealisations of previous models with regard to modelling the heat exchangers. In particular, it employs an elemental NTU- methodology to model both the shell-and-tube condenser and evaporator. The approach allows the change in heat transfer coefficients throughout the heat exchangers to be accounted for, thereby improving both physical realism and the accuracy of the simulation model. The model requires only those inputs that are readily available to the user (e.g. condenser inlet water temperature and evaporator water outlet temperature). The outputs of the model include system performance variables such as the compressor electrical work input and the coefficient of performance (COP) as well as states of the refrigerant throughout the refrigeration cycle. The methodology employed within the model also allows the performance of chillers using refrigerant mixtures to be modelled. The model is validated with data from one single screw chiller and one twin-screw chiller where the agreement is found to be within ±10%.  相似文献   

6.
Irreversibilities in components of an aqua-ammonia absorption refrigeratio system (ARS) have been determined by second law analysis. The components of the ARS are as follows: condenser, evaporator, absorber, generator, pump, expansion valves, mixture heat exchanger and refrigerant heat exchanger. It is assumed that the ammonia concentration at the generator exit is, independent of the other parameters, equal to 0.999 and at the evaporator exit the gas is saturated vapour. Pressrre losses between the generator and condenser, and the evaporator and absorber are taken into consideration. In the results the dimensionless exergy loss of each component, the exergetic coefficient of performance, the coefficient of performance and the circulation ratio are given graphically for each different generator, evaporator, condenser and absorber temperature.  相似文献   

7.
Thermal management system which can reject very high amount of heat by small thermal devices will be required for future space systems. Our purpose is to develop miniaturized heat rejection system that can reject more than 100 W/cm2. In the evaporator, thin liquid film vaporization which can dissipate very high heat flux, was utilized. The liquid film is stabilized in micro-channels by capillary forces. The microchannels are fabricated by chemical etching on silicon and copper plate. Also miniaturized condenser which utilized droplet condensation was tested. Droplets were produced on a cooled plate covered by non-wetting coating. After we built a heat rejection system constructed by above mentioned evaporator and condenser, influence of heat flux, coolant flow rate, and inlet temperature on the temperature of the heater element were investigated. Water is used as working fluid. Heat flux of 100 W/cm2 could be achieved for water inlet temperature in flow rate of 3.0 mL/min. The temperature of the heater element is kept constant at about 120°C.  相似文献   

8.
Discussion of the feasibility of the Einstein refrigeration cycle   总被引:4,自引:0,他引:4  
A careful modelling of the thermodynamic properties of the water–ammonia–butane system, the working fluid mixture used in the Einstein cycle, with the Patel–Teja cubic equation of state is performed. Numerical simulation is used to investigate the feasibility limits of this refrigeration cycle. Two modified configurations of the cycle are considered. A conflict between the evaporator and the condenser/absorber operating conditions is noted. The condenser/absorber operation needs a higher system pressure, which limits the refrigeration temperature in the case of air-cooling. On the other hand, the condensation of ammonia and the presence of a small quantity of water in the evaporator limit also the refrigeration temperature. In the case of a water-cooled machine, with a condenser/absorber temperature of 30 °C, the cycle COP reaches 0.19 which is still low.  相似文献   

9.
针对家用热泵空调器用的9.52 mm和7 mm双排室外换热器,在额定制冷制热工况下,利用仿真分析的方法研究流路数对换热器性能的影响,对9.52 mm换热器的流路的进一步优化,得到制冷制热综合性能更优的流路布置方式,并在整机上进行试验验证。结果表明,制冷剂侧压降对冷凝器和蒸发器的换热都有较大影响,特别是对较小管径的换热器;由于蒸发器中制冷剂侧压降较大,热泵空调器室外机用的换热器作冷凝器时对应的最佳流路数少于作蒸发器时的;适当增加过冷管数会进一步提高热泵空调器室外机换热器的综合换热能力;试验结果与仿真结果趋势大致相同。  相似文献   

10.
In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.  相似文献   

11.
A steady state simulation model has been developed to evaluate the system performance of a transcritical carbon dioxide heat pump for simultaneous heating and cooling. The simulated results are found to be in reasonable agreement with experimental results reported in the literature. Such a system is suitable, for example, in dairy plants where simultaneous cooling at 4 °C and heating at 73 °C are required. The optimal COP was found to be a function of the compressor speed, the coolant inlet temperature to the evaporator and inlet temperature of the fluid to be heated in the gas cooler and compressor discharge pressure. An optimizing study for the best allocation of the fixed total heat exchanger inventory between the evaporator and the gas cooler based on the heat exchanger area has been carried out. Effect of heat transfer in the heat exchangers on system performance has been presented as well. Finally, a novel nomogram has been developed and it is expected to offer useful guidelines for system design and its optimisation.  相似文献   

12.
A novel dynamic mathematical model based on spatially distributed approach has been developed and validated in this paper. This model gives good agreement in predicting the system COP and other parameters. The validated model has been used to enhance the prediction of the micro variations of superheat and sub-cooling. The novel spatial distributed model for the condenser and evaporator in refrigeration system, calculates the two-phase region in gas and liquid field separately since the gas and liquid in the two-phase region have different velocities. Previous researchers have used a pre-defined function of the void fraction in their spatially distributed model, based on experimental results. This approach results in the separate solution of the mass and energy equations, and less calculation is required. However, it is recognized that the mass and energy equations should be coupled during solving for more accurate solution. Based on the energy and mass balance, the spatial distribution model constructed here solves the velocity, pressure, refrigerant temperature, and wall temperature functions in heat exchangers simultaneously. A novel iteration method is developed and reduces the intensive calculations required. Furthermore, the condenser and evaporator models have shown a parametric distribution along the heat exchanger surface, therefore, the spatial distribution parameters in the two heat exchangers can be visualised numerically with a two-phase moving interface clearly shown.  相似文献   

13.
An accumulator heat exchanger (AHX) consists of an accumulator and an inner heat exchanger (IHX) contained in a shell. The AHX has been used in multi-air-conditioners to obtain system reliability and high performance by providing liquid refrigerant into expansion devices and preventing wet-compression. Energy is exchanged between the evaporator exit and the condenser exit in the AHX. In this study, the heat transfer characteristics of the AHX were investigated experimentally, and the effects of the AHX on the performance of a refrigeration system using R22 were measured. The operating characteristics of the refrigeration system with the AHX were considerably different from those without the AHX. The AHX system showed higher refrigerant flow rate than the non-AHX system at a constant EEV (electronic expansion valve) opening because of higher subcooling, resulting in better performance and reliability of the refrigeration system. At 50% EEV opening, the cooling capacity and COP of the AHX system were higher than those of the non-AHX system by 7.5% and 3.2%, respectively.  相似文献   

14.
The objective of this paper is to develop a new energy transport system for district cooling application by using type 2 absorption cycle. Cold energy from the LNG storage system is utilized as the cooling source of the condenser and the rectifier. The pressures of the system, UAs of the evaporator and the desorber, the inlet temperatures of the refrigerant for each component, transportation distance and the pumping power per unit length are considered as the key parameters. The results show that UA of the evaporator has more dominant effect on COP than that of the desorber. The optimum system pressure for the demand side is also determined. For the present system, it is recommended that the refrigerant inlet temperature of the evaporator be lower than 4.3 °C for long distance transportation. It is concluded that the cold energy from the LNG storage system can be effectively applied to the long distance transportation system for district cooling application with the type 2 absorption cycle. The maximum transportation distance and the pumping power per unit length are calculated. The optimum operation conditions are also predicted from the parametric analysis.  相似文献   

15.
A ‘three-temperature’ model of the adsorption cycles with heat regeneration is used for investigating and analysing the influence of different parameters on the performance of such cycles. The influence of the heat source temperature on the thermodynamic efficiency (COP/COPCarnot) is investigated. The result is that the thermodynamic efficiency of the cycle is always limited. In order to reduce the internal irreversibilities, different internal vapour transports for pressurising (depressurisation) the adsorber are investigated: first, adiabatic direct pressurisation (depressurisation) with the condenser (evaporator) instead of pressure changes by heat transfer; second, adiabatic internal vapour recovery between the adsorbers (partial pressurisation/depressurisation); third, separation of the adsorber into separate compartments between which vapour cannot be redistributed during pressurisation or depressurisation. Results show that the first process significantly reduces the COP, while the second one enhances the cooling power, and the third one does not change the performance. Analysis gives satisfactory explanation of these results.  相似文献   

16.
Carbon dioxide among natural refrigerants has gained a considerable attention as an alternative refrigerant due to its excellent thermophysical properties. In-tube evaporation heat transfer characteristics of carbon dioxide were experimentally investigated and analyzed as a function of evaporating temperature, mass flux, heat flux and tube geometry. Heat transfer coefficient data during evaporation process of carbon dioxide were measured for 5 m long smooth and micro-fin tubes with outer diameters of 5 and 9.52 mm. The tests were conducted at mass fluxes of from 212 to 656 kg m−2 s−1, saturation temperatures of from 0 to 20 °C and heat fluxes of from 6 to 20 kW m−2. The difference of heat transfer characteristics between smooth and micro-fin tubes and the effect of mass flux, heat flux, and evaporation temperature on enhancement factor (EF) and penalty factor (PF) were presented. Average evaporation heat transfer coefficients for a micro-fin tube were approximately 150–200% for 9.52 mm OD tube and 170–210% for 5 mm OD tube higher than those for the smooth tube at the same test conditions. The effect of pressure drop expressed by measured penalty factor of 1.2–1.35 was smaller than that of heat transfer enhancement.  相似文献   

17.
A single-stage vapour absorption refrigeration system (VARS) is tested with monochlorodifluoromethane (HCF22) as refrigerant and different absorbents: dimethylether of tetraethylene glycol (DMETEG) and dimethyl acetamide (DMA). The influence of generator temperatures in the range 75–95°C, which represents low-grade heat sources, is studied. Cooling water temperatures were varied between 20 and 30°C. Two cases of cooling water flow paths are considered, i.e. water entering either absorber or condenser, which are connected in series. For HCFC22-DMETEG, COP values in the range 0.2–0.36 and evaporator temperatures between 0 and 10°C are obtained. For HCF22-DMA, COP values in the range 0.3–0.45 and evaporator temperatures between −10 and 10°C are obtained. It is observed that HCFC22-DMETEG can work at lower heat source temperatures than HCFC22-DMA. However, at the same operating conditions HCFC22-DMA is better from the viewpoints of circulation ratio and COP. Experiments also show that at low heat source temperature, cooling water temperature has strong influence on circulation ratio but does not affect COP significantly. Preferably, cooling water should first flow through the condenser and then through the absorber in order to achieve improved overall performance.  相似文献   

18.
General models for the design of the heat exchangers (absorber, generator, condenser and evaporator) of a prototype of an air-cooled absorption chiller of 2 kW for air-conditioning using the pair H2O–LiBr have been developed. An absorption machine of such characteristics has been constructed to be used as a test facility for validating the results obtained from the mathematical models developed. The discrepancies considering the heat exchanged between numerical results and experimental data are under 15% in most cases for all these components except the condenser, where the discrepancies are higher. The conclusions reported will lead to: (i) future improvements of the mathematical simulation models and (ii) improvements in the experimental infrastructure.  相似文献   

19.
One of the authors has proposed a novel transport/storage system for the waste cold from the gasification process of liquefied natural gas (LNG), which consists of an evaporator, a cold trap, and a pipeline. In order to estimate the performance of this system, one should know the pressure in the evaporator, in which evaporation–freezing of a PCM occurs, and in the cold trap, as well as the pressure drop of the pipeline due to the flow of low pressure vapor of the PCM. In this paper, the cooling/freezing phenomena of a water droplet due to evaporation in an evacuated chamber was experimentally examined, and the heat transfer dominating the evaporation-freezing phenomena was investigated in order to estimate the pressure in the evaporator. From the results, it was shown that the water droplet in the evacuated cell is effectively cooled by the evaporation of water itself, and is frozen within a few seconds through a remarkable supercooling state, and that the cooling rate of the water droplets were dominated by heat transfer within the droplet under the abrupt evacuation condition. The later result means that, in order to obtain an ice particle by evaporation–freezing, the surroundings of the water droplet should be evacuated at the pressure as low as the saturate pressure of water at the maximum supercooling temperature of the droplet.  相似文献   

20.
This paper presents the experimental heat transfer coefficients and pressure drop measured during refrigerant R134a vaporisation inside a small brazed plate heat exchanger (BPHE): the effects of heat flux, refrigerant mass flux, saturation temperature and outlet conditions are investigated. The BPHE tested consists of 10 plates, 72 mm in width and 310 mm in length, which present a macro-scale herringbone corrugation with an inclination angle of 65° and corrugation amplitude of 2 mm.The experimental results are reported in terms of refrigerant side heat transfer coefficients and frictional pressure drop. The heat transfer coefficients show great sensitivity both to heat flux and outlet conditions and weak sensitivity to saturation temperature. The frictional pressure drop shows a linear dependence on the kinetic energy per unit volume of the refrigerant flow.The experimental heat transfer coefficients are also compared with two well-known correlations for nucleate pool boiling and a correlation for frictional pressure drop is proposed.  相似文献   