换热器传热强化的管束试验研究 总被引:4,自引:0,他引:4
以铜-镍合金整体低肋管和整体内外翅片管为元件,以油-水和水-水为介质为管束换热器模拟体进行了试验研究。试验结果表明,低肋管对于油-水换热,内外翅片管对于水-水换热有着比较明显的传热强化效果。在额定工况下,低肋管油-水换热模拟体的总传热系数是光滑管模拟体的1.59倍,可相应节省换热面积37%,管外油流的压力降较光管降低33%;内外翅片管水-水换热模拟体的总传热系数是光滑管的1.31倍,可节省换热面积 相似文献
7.
螺旋管内单相及沸腾的强化换热与阻力特性实验 总被引:2,自引:0,他引:2
实验研究了三维内肋螺旋管内单相及沸腾的强化换热与阻力性能。单相对流换热实验采用光滑螺旋管和两种不同结构尺寸的三维内肋螺旋管。与光滑螺旋管相比,在测试的流动范围内.两种三维内肋管的平均换热系数增加了71%和103%.平均阻力增加了90%和140%;曲率δ=0.0605、测试段长0.58m的三维内微肋螺旋管内流动沸腾换热实验结果表明:在不同质量流速、热流密度工况下,三维内微肋螺旋管的平均换热系数比光滑螺旋管增加40%到120%.阻力增加18%到119%。 相似文献
8.
以去离子水为实验介质,在单面受热流密度条件下,开展了聚变装置偏滤器的过冷流动沸腾强化换热特性实验研究,将内肋强化换热技术与内插扭带结构相结合,利用两者的协同强化传热效应,设计出一种复合换热管。实验参数为:质量流速,992~4 960 kg/(m2·s);压力,04~2 MPa;入口过冷度,8701~11921 ℃;热流密度,1~163 MW/m2。对4种强化换热管(光管、内插扭带管、内螺纹肋管和复合换热管)的管内过冷流动沸腾换热特性和综合性能评价指标(PEC)进行了对比实验。结果表明:与其他3种管道相比,复合换热管的对流换热系数和PEC最高,传热特性最好。研究了复合换热管的扭带扰动比、螺距、压力和质量流速对管内两相流动对流换热系数的影响规律,发现对流换热系数与螺距、质量流速呈正比,与扭带扰动比、压力呈反比。最后对比了4个现有的过冷流动沸腾换热经验公式,并在无量纲模型基础上,增加了扰动比和螺径比(t/Dh)进行修正,利用非线性拟合方法提出了适合复合换热管过冷流动沸腾的努塞尔数新公式。 相似文献
9.
换热器传热强化单管筛选试验研究 总被引:5,自引:0,他引:5
介绍了油-水强化换热用整体外肋管和水-水强化换热用整体内,外翅片管的单管筛选试验情况,给出了传热和阻力测试结果,并给出了回归的传热系数关联式。试验结果表明,外肋管的总传热系数比光管提高约15%,内、外翅片管比光管提高约50%。 相似文献
10.
11.
12.
以浸没在高位水箱中的竖直管束为研究对象,对不同热负荷条件下竖直管束的池沸腾换热特性进行研究,通过对比中心管与周围旁管外壁面过热度、凝液量的变化,分析了中心管与旁管换热特性的差异。实验结果表明,换热管束的换热能力明显优于单管,在相同热流密度条件下,管束沸腾换热系数可达到单管的1.2~1.5倍。与旁管相比,低热负荷条件下,中心管的换热能力优于旁管;高热负荷条件下,中心管的换热能力则不及旁管,在热流密度大于200 kW/m2时,旁管的沸腾换热系数相对于中心管提高了近7%,且从实验数据的变化趋势来看,旁管较中心管的沸腾换热能力有随热流密度增加而逐渐增大的趋势。 相似文献
13.
以润滑油为换热介质,对1个光管滑油冷却器和3个采用了针翅管的滑油冷却器实验体进行了对比实验研究。结果表明:在本实验范围内,针翅管滑油冷却器的总传热系数较高,是相同条件下光管滑油冷却器总传热系数的1.4~2倍;不同结构针翅管滑油冷却器的传热与阻力性能差别较大,针翅管结构参数和壳侧流程数目是影响滑油冷却器壳程传热与阻力性能的主要因素。实验范围内,较大的针翅高度有利于油流体的扰动,但不利于针翅管一次传热面处的换热;单流程结构的针翅管滑油冷却器具有较高的传热系数和单位体积换热量,其总体换热性能与阻力性能优于双流程结构的针翅管滑油冷却器。 相似文献
14.
15.
沸腾换热具有传热温差低、换热系数高等优点,对提高设备的紧凑性、经济性和安全性具有重要意义.目前,核动力装置中主要以光管作为沸腾换热元件,沸腾换热强化的空间很大.本文针对核动力装置非能动余热排出换热器沸腾换热工况,以水为工质,对光管及3种强化管的管外沸腾换热特性进行实验研究,得出了4种管型的沸腾换热强化特性,并分析了各强化管的强化机理.整体针翅管表面大量螺旋排列的三维翅片增大了换热面积、延缓了汽泡在壁面附近聚合形成大汽膜,使沸腾换热得到强化;多孔管采用机械方法在壁面加工出大量微细小孔,汽化核心数量和汽泡脱离频率均大幅提高,因此,沸腾换热强化效果显著;绕丝针翅管是一种复合强化手段,兼有整体针翅管和多孔管的优点,沸腾换热强化效果也较好. 相似文献
16.
17.
钠-空气热交换器是钠冷快堆事故余热排出系统的重要设备之一,与外界环境一起构成事故下反应堆余热的最终热阱。由于钠-空气热交换器的换热管采用垂直布置的翅片管结构,空气在不同位置处冲刷换热管的流速以及角度不同,导致其传热特性及阻力特性与传统翅片管换热器有很大不同。本文以钠-空气热交换器工程设计需求为研究背景,设计了两种试验件分别进行空气冲刷角度为90°和30°时翅片管束传热与流动阻力特性试验研究。试验结果表明:对于相同管排,空气冲刷角度为90°时的翅片管的换热系数及阻力系数明显大于空气冲刷角度为30°时的翅片管;对于相同空气冲刷角度下的不同换热管排,第2排翅片管的换热系数最大。本文研究为钠-空气热交换器的设计及优化提供了理论依据。 相似文献
18.
Sodium-air heat exchanger is one of the important equipment in the decay heat removal system of sodium-cooled fast reactor, which together with the external environment constitutes the final heat trap for the residual heat of a reactor. Due to the vertically arranged finned tube structure adopted by the heat exchanger tubes of the sodium-air heat exchanger and the difference of the flow direction and velocity of the air at the different positions, the heat transfer and resistance characteristics are very different from of traditional finned tube heat exchanger. In this paper, based on the engineering design requirements of sodium-air heat exchanger, two kinds of experimental specimens were designed to study the heat transfer and flow resistance characteristics of finned tube bundles with air flow angles of 90° and 30°. The experimental results show that the heat transfer and resistance coefficients of the same finned tube with air flow angles of 90° are significantly greater than those of the finned tube with air flow angles of 30°. For the same air flow direction, the second finned tube has the largest heat transfer coefficient. The research provides a theoretical basis for the design and optimization of sodium-air heat exchanger. 相似文献
19.
《Journal of Nuclear Science and Technology》2013,50(11):936-947
Two-phase friction pressure drop and heat transfer coefficients in a once-through steam generator with helically coiled tubes were investigated with the model test rig of an integrated type marine water reactor. As the dimensions of the heat transfer tubes and the thermal-fluid conditions are almost the same as those of real reactors, the data applicable directly to the real reactor design were obtained. As to the friction pressure drop, modified Kozeki's prediction which is based on the experimental data by Kozeki for coiled tubes, agreed the best with the experimental data. Modified Martinelli-Nelson's prediction which is based on Martinelli-Nelson's multiplier using Ito's equation for single-phase flow in coiled tube, agreed within 30%. The effect of coiled tube on the average heat transfer coefficients at boiling region were small, and the predictions for straight tube could also be applied to coiled tube. Schrock-Grossman's correlation agreed well with the experimental data at the pressures of lower than 3.5 MPa. It was suggested that dryout should be occurred at the quality of greater than 90% within the conditions of this report. 相似文献