In this study, therma l performance of two hydrocarbon refrigerants of R290 and R1270 was measured in an attempt to substitute
R22. They wer tested in a heat pump bench tester of 1 ton capacity with a hermetic rotary compressor. Water and water/glycol
mixture were employed as the secondary heat transfer fluids in the test bench. All tests were conducted under the same external
conditions simulating three different air-conditioning and heat pumping conditions. Test results show that the coefficient
of performance of these hydrocarbon refrigerants is up to 11.5% higher than that of R22 under all conditions. Refrigeration
capacity of R290 is up to 8.2% lower than that of R22 under normal air-conditioning and heat pumping conditions. Under extremely
cold temperature conditions, however, the capacity of R290 is 5% higher than that of R22. On the other hand, the capacity
of R1270 is similar to that of R22 under all conditions. Compressor discharge temperatures of these hydrocarbons are reduced
by 14–31°C as compared to R22. The amount of charge is reduced up to 58% as compared to R22. Overall, these hydrocarbons provide
good performance with reasonable energy savings without any environmental problems and thus can be used as long-term alternatives
for residential air-conditioning and heat pumping applications. 相似文献
2.
对比研究了分别采用R22及其替代工质R410a的平行流冷凝器在室外变工况下性能的同异。通过建立平行流冷凝器的稳态分布参数模型,仿真研究了不同冷凝温度下R410a和R22的变工况特性,并引入质能比的概念对这两种工质的单位换热量所需制冷剂质量的多少进行了比较。仿真结果是R410a和R22的换热量、制冷剂侧压降和制冷剂质量随工况和冷凝温度的改变具有的相似的变化趋势,且R410a具有较高的换热量和较低的压降;两者的质能比随进风温度和进风量的升高均呈基本一致的向上抛物线的变化趋势,且R410的质能比低于R22。可以得出R410a与R22具有相似的变工况特性,适合替代R22应用于采用平行流冷凝器的汽车空调。并且R410a在传热、流动性能和降低制冷剂充注量方面均优于R22。 相似文献
3.
Ki-Jung Park Yohan Lee Dongsoo Jung 《Journal of Mechanical Science and Technology》2010,24(4):879-885
In this study, the performance of R170/R1270 mixture was measured on a heat pump bench tester to substitute for R22. The tester was equipped with a hermetic compressor providing a nominal capacity of 3.5 kW. All tests were conducted under typical summer and winter conditions of 7/45°C and ?7/41°C in the evaporator and condenser, respectively. During the tests, the composition of R170 varied from 0 to 10% with an interval of 2% for the R170/R1270 mixture. Test results showed that the capacities of the R1270 and R170/R1270 mixtures were 3.2–10.0% and 4.2–20.4% higher than those of R22, respectively. The coefficient of performance (COP) of R1270 was 2.7–3.6% higher than that of R22. On the other hand, the COP of R170/R1270 mixture decreased at a constant rate as R170 was added to R1270. The COP of R170/R1270 mixture was similar to that of R22 at 2% R170 and then became lower than those of R22 as R170 increased. For the mixture, the compressor discharge temperature was 8–20°C lower than that of R22. The amount of charge was reduced up to 55% compared with R22. Overall, pure propylene and R170/R1270 mixtures are good long-term candidates from the viewpoint of energy efficiency and greenhouse warming to replace R22 in residential air-conditioners and heat pumps. 相似文献
4.
In this study, external condensation heat transfer coefficients (HTCs) of HCFC22, R410A, R407C, and HFC134a were measured
on a smooth horizontal tube at 30, 39, and 50°C with the wall subcooling of 3–8°C. The results showed that condensation HTCs
decreased for all fluids tested with an increase in temperature. This is due mainly to such properties as the saturated liquid
density and liquid thermal conductivity. These properties decrease as the temperature increase and accordingly HTCs decrease.
The condensation HTCs of R410A are 9.2–19.7% higher than those of HCFC22 while those of R134a are 2.5–10.2% lower than those
of HCFC22. Condensation HTCs of R407C, non-azeotropic mixture, are 29.4–34.3% lower than those of HCFC22. Overall, the HTCs
of R407C are much lower than those of HCFC22, HFC134a and R410A due to the mass transfer resistance in a diffusion vapor film.
Condensation HTCs of HCFC22 and HFC134a are higher than those calculated by Nusselt’s equation by 7.7–11.8% and 4.0–11.1%
respectively. On the other hand, HTCs of R407C measured on plain tube, however, are not well predicted by these well-known
prediction correlations due to the introduction of mass transfer resistance associated with non-azeotropic mixtures. 相似文献
5.
6.
部分负荷工况下螺杆制冷压缩机特性试验研究 总被引:5,自引:0,他引:5
研究了采用不同工质时螺杆制冷压缩机在部分负荷工况下的性能特性。通过录取半封闭螺杆压缩机工作过程指示图(p-V图),获得了部分负荷下螺杆制冷压缩机的效率及其变化规律,并根据部分负荷下压缩机内容积比的变化,对这种变化规律进行了解释。随后对螺杆压缩机采用R22、R134a、R404A、R407C四种不同工质时,在部分负荷工况下的性能变化规律进行了分析比较。研究结果表明:随着负荷的降低,压缩机的绝热效率和绝热指示效率都会有明显的下降,但机组系统的性能系数PCO会有明显的上升;使用R22工质时机组的使用部分负荷值VAPL为最佳。 相似文献
7.
8.
9.
10.
以一台变转速热泵空调器为研究对象,测试其在冬季用R32做制冷剂时机组的能效及换热器的传热性能,以研究制热工况下空调系统中用R32作为替代制冷剂的可行性。试验测量参数包括蒸发器(室外机)和冷凝器(室内机)的传热系数、换热量、总压力降以及整机制热工况下的COP。通过结构匹配的室内、外侧两换热器在系统运行中同步测量,结果表明:冬季名义制热工况下,R32空调系统的制热能力比用R410A高出约3.0%,蒸发器、冷凝器的传热系数也有所提高,其中蒸发器的传热性能提高约6.0%,冷凝器传热性能提高约6.7%,而压降对比则变化不大。 相似文献
11.
分析了R290应用于家用空调的优势及可行性,采用某企业生产的R22家用冷风型分体机,直接充注R290制冷剂,在焓差实验室内调整毛细管规格及制冷剂灌注量,使性能达到最佳状态,结果表明:R22系统直接灌注R290制冷剂,灌注量仅为原来的44.7%,但制冷量下降13.64%,能效比稍有提高。为进一步减小灌注量、提高制冷量,采用了平行流换热器作为冷凝器,重新调整灌注量及毛细管规格,结果显示R290灌注量大幅减少,制冷量及能效比显著提高,R290灌注量的减少有利于制冷系统的安全性。 相似文献
12.
13.
14.
15.
Ki-Jung Park Yohan Lee Dongsoo Jung 《Journal of Mechanical Science and Technology》2010,24(4):873-878
In this study, the performance of R170/R1270 mixture was measured on a heat pump bench tester to substitute for R22. The tester
was equipped with a hermetic compressor providing a nominal capacity of 3.5 kW. All tests were conducted under typical summer
and winter conditions of 7/45°C and −7/41°C in the evaporator and condenser, respectively. During the tests, the composition
of R170 varied from 0 to 10% with an interval of 2% for the R170/R1270 mixture. Test results showed that the capacities of
the R1270 and R170/R1270 mixtures were 3.2–10.0% and 4.2–20.4% higher than those of R22, respectively. The coefficient of
performance (COP) of R1270 was 2.7–3.6% higher than that of R22. On the other hand, the COP of R170/R1270 mixture decreased
at a constant rate as R170 was added to R1270. The COP of R170/R1270 mixture was similar to that of R22 at 2% R170 and then
became lower than those of R22 as R170 increased. For the mixture, the compressor discharge temperature was 8–20°C lower than
that of R22. The amount of charge was reduced up to 55% compared with R22. Overall, pure propylene and R170/R1270 mixtures
are good long-term candidates from the viewpoint of energy efficiency and greenhouse warming to replace R22 in residential
air-conditioners and heat pumps. 相似文献
16.
17.
依据GB/T7725—2004规定的试验工况,分别对应用R32和R290的空调系统进行性能测试。在理论分析的基础上,依据试验数据,对比分析两种替代制冷剂的优缺点及其系统的改进方法。结果表明:R32单位容积制冷量高出R290约87%左右,相同制冷量下R290系统应使用更大排量的压缩机。R32具有较高的排气温度,并且R32系统相比R290系统,压比高出约7%,系统整体的能效比低约3.7%。R290系统换热器的压降要小于R32,有助于提高系统性能。但其可燃性远远大于R32,在安全设计方面有着更高的花费,系统初期改造投入比较高。 相似文献
18.
19.
对制冷剂R427a在空气源热泵热水器上的应用做了研究,并与常用制冷剂R22和R134a在典型工况下做了对比分析,分析了3种制冷剂的吸排气压力、吸排气温度、压缩机功率、制热量、性能系数随环境工况变化的关系,得出了各特性参数的变化规律;另外在5℃进出水温差条件下,热水进水温度每上升5℃(如50℃进水,55℃进水,60℃进水)时,制热量下降2%~3%;COP下降10%~11%;功率上升11%~13%;吸排气压力分别上升3%~4%、10%~15%;吸排气温度分别上升5%、10%左右;这些为热泵热水器的设计使用及工质选用提供了参考。 相似文献