1.
Decentralization of electrical power generation using rooftop solar units is projected to develop to not only mitigate power losses along transmission and distribution lines, but to control greenhouse gases emissions. Due to intermittency of solar energy, traditional batteries are used to store energy. However, batteries have several drawbacks such as limited lifespan, low storage capacity, uncontrolled discharge when not connected to a load and limited number of charge/discharge cycles. In this paper, the feasibility of using hydrogen as a battery is analyzed where hydrogen is produced by the extra diurnal generated electricity by a rooftop household solar power generation unit and utilized in a fuel cell system to generate the required electrical power at night. In the proposed design, two rooftop concentrated photovoltaic thermal (CPVT) systems coupled with an organic Rankine cycle (ORC) are used to generate electricity during 9.5 h per day and the extra power is utilized in an electrolyzer to produce hydrogen. Various working fluids (Isobutane, R134a, R245fa and R123) are used in the ORC system to analyze the maximum feasible power generation by this section. Under the operating conditions, the generated power by ORC as well as its efficiency are evaluated for various working fluids and the most efficient working fluid is selected. The required power for the compressor in the hydrogen storage process is calculated and the number of electrolyzer cells required for the hydrogen production system is determined. The results indicate that the hybrid CPVT-ORC system produces 2.378 kW of electricity at 160 suns. Supplying 65% of the produced electricity to an electrolyzer, 0.2606 kg of hydrogen is produced and stored for nightly use in a fuel cell system. This amount of hydrogen can generate the required electrical power at night while the efficiency of electrolyzer is more than 70%.  相似文献   

2.
The present study aimed to investigate a multi-generation energy system for the production of hydrogen, freshwater, electricity, cooling, heating, and hot water. Steam Rankine cycle (SRC), organic Rankine cycle (ORC), absorption chiller, Parabolic trough collectors (PTCs), geothermal well, proton exchange membrane (PEM) electrolyzer, and reverse osmosis (RO) desalination are the main subsystems of the cycle. The amount of exergy destruction is calculated for each component after modeling and thermodynamic analysis. The PTCs, absorption chiller, and PEM electrolyzer had the highest exergy destruction, respectively. According to meteorological data, the system was annually and hourly tested for Dezful City. For instance, it had a production capacity of 13.25 kg/day of hydrogen and 147.42 m3/day of freshwater on 17th September. Five design parameters are considered for multi-objective optimization after investigating objective functions, including cost rate and exergy efficiency. Using a Group method of data handling (GMDH), a mathematical relation is obtained between the input and output of the system. Next, a multi-objective optimization algorithm, a non-dominated sorting genetic algorithm (NSGA-II), was used to optimize the relations. A Pareto frontier with a set of optimal points is obtained after the optimization. In the Pareto frontier, the best point is selected by the decision criterion of TOPSIS. At the TOPSIS point, the exergy efficiency is 31.66%, and the total unit cost rate is 21.9 $/GJ.  相似文献   

3.
Hydrogen is one of the most clean energy carrier and the best alternative for fossil fuels. In this study, thermodynamic analysis of modified Organic Rankine Cycle (ORC) integrated with Parabolic Trough Collector (PTC) for hydrogen production is investigated. The integrated system investigated in this study consists of a parabolic trough collector, a modified ORC, a single effect absorption cooling system and a PEM electrolyzer. By using parabolic trough collector, solar energy is converted heat energy and then produced heat energy is used in modified ORC to produce electricity. Electricity is then used for hydrogen production. The outputs of this integrated system are electricity, cooling and hydrogen. By performing a parametric study, the effects of design parameters of PTC, modified ORC and PEM electrolyzer on hydrogen production is evaluated. According to the analysis results, solar radiation is one of the most important factor affecting system exergy efficiency and hydrogen production rate. As solar radiation increases from 400?W/m2 to 1000?W/m2, exergy efficiency of the system increases 58%–64% and hydrogen production rate increases from 0.1016?kg/h to 0.1028?kg/h.  相似文献   

4.
In this paper, a salinity gradient solar pond (SGSP) is used to harness the solar energy for hydrogen production through two cycles. The first cycle includes an absorption power cycle (APC), a proton exchange membrane (PEM) electrolyzer, and a thermoelectric generator (TEG) unit; in the second one, an organic Rankine cycle (ORC) with the zeotropic mixture is used instead of APC. The cycles are analyzed through the thermoeconomic vantage point to discover the effect of key decision variables on the cycles’ performance. Finally, NSGA-II is used to optimize both cycles. The results indicate that employing ORC with zeotropic mixture leads to a better performance in comparison to utilizing APC. For the base mode, unit cost product (UCP), exergy, and energy efficiency when APC is employed are 59.9 $/GJ, 23.73%, and 3.84%, respectively. These amounts are 47.27 $/GJ, 29.48%, and 5.86% if ORC with the zeotropic mixture is utilized. The APC and ORC generators have the highest exergy destruction rate which is equal to 6.18 and 10.91 kW. In both cycles, the highest investment cost is related to the turbine and is 0.8275 $/h and 0.976 $/h for the first and second cycles, respectively. In the optimum state the energy efficiency, exergy efficiency, UCP, and H2 production rate of the system enhances 42.44%, 27.54%,15.95%, and 38.24% when ORC with the zeotropic mixture is used. The maximum H2 production is 0.47 kg/h, and is obtained when the mass fraction of R142b, LCZ temperature, pumps pressure ratio, generator bubble point temperature are 0.603, 364.35 K, 2.12, 337.67 K, respectively.  相似文献   

5.
One of the essential steps to design energy conversion-based systems is choosing an efficient working fluid under the design goals to access stable products with high efficiency and overcome environmental issues. In this regard, the current paper is motivated to devise and evaluate a novel geothermal-driven multigeneration system under the effect of various working fluids. The proposed system consists of a flash-binary geothermal power plant, an organic flash cycle (OFC), a power/cooling subsystem (an organic Rankine cycle (ORC) and a thermoelectric generator incorporated with a compression refrigeration cycle), and freshwater and hydrogen production units utilizing a humidification-dehumidification desalination unit and a low-temperature electrolyzer. Considering the design potential of the OFC and ORC, four different environmentally-friendly working fluids, i.e., R123 and R600 in the OFC and R1234yf and R1234ze(e) in the ORC are selected and classified in four groups to introduce the best one, under the energy, exergy, and economic (3E analysis) approaches. Also, the whole system is optimized through a genetic algorithm, respecting the optimal solution for the energy efficiency and unit exergy cost of the products. According to the results, R123/R1234ze(e) shows the highest cooling, hydrogen, freshwater production rates, and energy efficiency. Likewise, the maximum power generation and exergy efficiency belong to R600/R1234ze(e). Moreover, R600/R1234yf has the lowest unit exergy cost of products.  相似文献   

6.
In this study, power and hydrogen production performance of an integrated system is investigated. The system consists of an organic Rankine cycle (ORC), parabolic trough solar collectors (PTSCs) having a surface area of 545 m2, middle-grade geothermal source (MGGS), cooling tower and proton exchange membrane (PEM). The final product of this system is hydrogen that produced via PEM. For this purpose, the fluid temperature of the geothermal source is upgraded by the solar collectors to drive the ORC. To improve the electricity generation efficiency, four working fluids namely n-butane, n-pentane, n-hexane, and cyclohexane are tried in the ORC. The mass flow rate of each working fluid is set as 0.1, 0.2, 0.3, 0.4 kg/s and calculations are made for 16 different situations (four types of working fluids and four different mass flow rates for each). As a result, n-butane with a mass flow rate of 0.4 kg/s is found to be the best option. The average electricity generation is 66.02 kW between the hours of 1100-1300. The total hydrogen production is 9807.1 g for a day. The energy and exergy efficiency is calculated to be 5.85% and 8.27%, respectively.  相似文献   

7.
In this research paper, a newly energy system consisting of parabolic trough solar collectors (PTSC) field, a thermoelectric generator (TEG), a Rankine cycle and a proton exchange membrane (PEM) is proposed. The integration is performed by establishing a TEG instead of the condenser as power generation and cooling unit thereafter surplus power output of the TEG is transferred to the PEM electrolyzer for hydrogen production. The integrated renewable energy system is comprehensively modeled and influence of the effective parameters is investigated on exergy and economic indicators through the parametric study to better understand the system performance. Engineering equation solver (EES) as a potential engineering tool is used to simulate the system and obtain the desired results. In order to optimize the system, a developed multi-objective genetic algorithm MATLAB code is applied to determine the optimum operating conditions of the system. Obtained results demonstrate that at optimum working condition from exergy viewpoint, exergy efficiency and total cost are 12.76% and 61.69 $/GJ, respectively. Multi-objective optimization results further show that the final optimal point which is well-balanced between exergy efficiency and total cost, has the maximum exergy efficiency of 13.29% and total cost of 63.96 $/GJ, respectively. The corresponding values for exergy efficiency and total cost are 10.01% and 60.21 $/GJ for optimum working condition from economic standpoint. Furthermore, hydrogen production at well-balanced operating condition would be 2.28 kg/h. Eventually, the results indicate that establishing the TEG unit instead of the condenser is a promising method to optimize the performance of the system and reduce total cost.  相似文献   

8.
Cold energy during the LNG regasification process is usually applied for power generation, but the electricity demand varies with the time. Therefore, a thought that transforming electrical energy into hydrogen energy by PEM electrolyzer is put forward to adjust the adaptability of power output to electricity demand. This paper proposes a new double-pressure condensation Rankine cycle integrated with PEM electrolyzer for hydrogen production. In this system, seawater is used as the heat source, and binary mixed working fluids are applied. Meanwhile, multi-stream heat exchanger is introduced to improve the irreversibility of heat transfer between LNG and working fluid. The key system parameters, including seawater temperature, the first-stage condensation temperature, the second-stage condensation temperature, and outlet temperature of LNG, are studied to clarify their effects on net power generation, hydrogen production rate and energy efficiency. Furthermore, the hydrogen production rate is as the objective function, these parameters are optimized by genetic algorithm. Results show that seawater temperature has positive impact on the net power output and hydrogen production rate. The first-stage condensation temperature, the second-stage condensation temperature, and outlet temperature of LNG have diverse effects on the system performance. Under the optimal working conditions, when the LNG regasification pressure are 600, 2500, 3000 and 7000 kPa, the increasing rate for optimized net power output, hydrogen production rate and energy efficiency are more than 11.68%, 11.67% and 8.88%, respectively. The cost of hydrogen production with the proposed system varies from 1.93 $/kg H2 to 2.88 $/kg H2 when LNG regasification pressure changes from 600 kPa to 7000 kPa.  相似文献   

9.
In the last decades, heat recovery systems have received much attention due to the increase in fuel cost and the increase in environmental issues. In this study, different heat recovery systems for a cement plant are compared in terms of electricity generation and exergy analysis. The heat sources are available in high temperature (HT) and low temperature (LT). For the HT section a dual pressure Rankine cycle, a simple dual pressure Organic Rankine Cycle (ORC) and a regenerative dual pressure ORC are compared. Also, for the LT section, a simple ORC is compared with transcritical carbon dioxide cycle. To find the best system, an optimisation algorithm is applied to all proposed cycles. The results show that for the HT section, regenerative ORC has the highest exergy efficiency and has the capability of producing nearly 7?MW electricity for a cement factory with the capacity of 3400 ton per day. The main reason for this is introducing the regenerative heat exchanger to the cycle. For the LT section, ORC showed a better performance than the CO2 cycle. It is worth mentioning that the generated power in this section is far lower than that of the HT section and is equal to nearly 300?kW.  相似文献   

10.
Proton-exchange membrane fuel cell (PEMFC) and liquid hydrogen are gaining attention as a power generation system and alternative fuel of ship. This study proposes a novel PEMFC system, integrated with the organic Rankine cycle–direct expansion cycle (ORC-DEC), which exploits cold exergy from liquid hydrogen and low temperature waste heat generated by the PEMFC for application in a liquid hydrogen fueled ship. A thermodynamic model of each subsystem was established and analyzed from the economic, energy, and exergy viewpoints. Moreover, parametric analysis was performed to identify the effects of certain key parameters, such as the working fluid in the ORC, pressure exerted by the fuel pump, cooling water temperature of the PEMFC, and the stack current density on the system performance. The results showed that the proposed system could generate 221 kW of additional power. The overall system achieved an exergy and energy efficiency of 43.52 and 40.45%, respectively. The PEMFC system had the largest exergy destruction, followed by the cryogenic heat exchanger. Propane showed the best performance among the several investigated ORC working fluids and the system performance improved with the increase in the cooling water temperature of the PEMFC. The economic analysis showed that the average payback time of ORC-DEC was 11.2 years and the average net present value (NPV) was $295,268 at liquid hydrogen costing $3 to $7, showing the potential viability of the system.  相似文献   

11.
This article presents an innovative combined heat and power system comprising a solid oxide fuel cell (SOFC), a heat recovery unit, and a lithium bromide absorption power cycle (APC). The energy, exergy, economic, and environmental perspectives of the proposed system are compared against the same configuration using an organic Rankine cycle (ORC), recovering the waste heat of the SOFC. A multi-criteria optimization based on the Grey Wolf approach is applied to each system to specify the best operation conditions having the exergy efficiency and total cost rate as the objectives. Furthermore, a parametric investigation is conducted to assess the effects of changing the decision variables on the systems proficiencies. The results indicate that although the ORC-based cycle is economically very slightly superior, the integration of the SOFC with the APC offers a much higher exergy efficiency due to the better temperature matching between the working fluid and heat source. Optimization can increase the exergy efficiencies of the SOFC-ORC and the SOFC-APC systems by about 13.8% and 14.7% while reducing the total cost rate by 11.2 $/h and 11.0 $/h, respectively, compared to the base system. Environmental analysis results reveal that APC use leads to a lower emission of 2.8 kg/MWh.  相似文献   

12.
In this study, biogas power production and green hydrogen potential as an energy carrier are evaluated from biomass. Integrating an Organic Rankine Cycle (ORC) to benefit from the waste exhaust gases is considered. The power obtained from the ORC is used to produce hydrogen by water electrolysis, eliminate the H2S generated during the biogas production process and store the excess electricity. Thermodynamic and thermoeconomic analyses and optimization of the designed Combined Heat and Power (CHP) system for this purpose have been performed. The proposed study contains originality about the sustainability and efficiency of renewable energy resources. System design and analysis are performed with Engineering Equation Solver (EES) and Aspen Plus software. According to the results of thermodynamic analysis, the energy and exergy efficiency of the existing power plant is 28.69% and 25.15%. The new integrated system's energy, exergy efficiencies, and power capacity are calculated as 41.55%, 36.42%, and 5792 kW. The total hydrogen production from the system is 0.12412 kg/s. According to the results of the thermoeconomic analysis, the unit cost of the electricity produced in the existing power plant is 0.04323 $/kWh. The cost of electricity and hydrogen produced in the new proposed system is determined as 0.03922 $/kWh and 0.181 $/kg H2, respectively.  相似文献   

13.
In this study, a novel multi-generation system is proposed by integrating a solid oxide fuel cell (SOFC)-gas turbine (GT) with multi-effect desalination (MED), organic flash cycle (OFC) and polymer electrolyte membrane electrolyzer (PEME) for simultaneous production of electricity, fresh water and hydrogen. A comprehensive exergoeconomic analysis and optimization are conducted to find the best design parameters considering exergy efficiency and total unit cost of products as objective functions. The results show that the exergy efficiency and the total unit cost of products in the optimal condition are 59.4% and 23.6 $/GJ, respectively, which offers an increase of 2% compared to exergy efficiency of SOFC-GT system. Moreover, the system is capable of producing 2.5 MW of electricity by the SOFC-GT system, 5.6 m3/h of fresh water by MED unit, and 1.8 kg/h of hydrogen by the PEME. The associated cost for producing electricity, fresh water and hydrogen are 3.4 cent/kWh, 37.8 cent/m3, and 1.7 $/kg, respectively. A comparison between the results of the proposed system and those reported in other related papers are presented. The diagram of the exergy flow is also plotted for the exact determination of the exergy flow rate in each component, and also, location and value of exergy destruction. Finally, the capability of the proposed system for a case study of Iran is examined.  相似文献   

14.
A novel solid oxide fuel cell (SOFC) multigeneration system fueled by biogas derived from agricultural waste (maize silage) is designed and analyzed from the view point of energy and exergy analysis. The system is proposed in order to limit the greenhouse gas emissions as it uses a renewable energy source as a fuel. Electricity, domestic hot water, hydrogen and cooling load are produced simultaneously by the system. The system includes a solid oxide fuel cell; which is the primary mover, a biogas digester subsystem, a cascaded closed loop organic Rankine cycle, a single effect LiBr-water absorption refrigeration cycle, and a proton exchange membrane electrolyzer subsystem. The proposed cascaded closed-loop ORC cycle is considered as one of the advanced heat recovery technologies that significantly improve thermal efficiency of integrated systems. The thermal performance of the proposed system is observed to be higher in comparison to the simple ORC and the recuperated ORC cycles. The integration of a splitter to govern the flue gas separation ratio is also introduced in this study to cater for particular needs/demands. The separation ratio can be used to vary the cooling load or the additional power supplied by the ORC to the system. It is deduced that net electrical power, cooling load, heating capacity of the domestic hot water and total energy and exergy efficiency are 789.7 kW, 317.3 kW, 65.75 kW, 69.86% and 47.4% respectively under integral design conditions. Using a parametric approach, the effects of main parameters on the output of the device are analyzed. Current density is an important parameter for system performance. Increasing the current density leads to increased power produced by the system, decreased exergy efficiency in the system and increased energy efficiency. After-burner, air and fuel heat exchangers are observed to have the highest exergy destruction rates. Lower current density values are desirable for better exergy-based sustainability from the exergetic environmental impact assessment. Higher current density values have negative effect on the environment.  相似文献   

15.
This study aims to develop a novel integrated geothermal based system by the application of different thermodynamic cycles such as Kalina, liquefied natural gas (LNG), Stirling and proton exchange membrane electrolyzer (PEME) to produce cooling, hydrogen, and electricity. Energy and exergy analyses of the system are performed to evaluate the performance of the system. Additionally, the effects of five different input variables are investigated to determine their impacts on the corresponding values of net power and cooling, exergy efficiency, hydrogen production, and sustainability index. In a defined condition, the exergy efficiency of the suggested system is computed around 43%. The cycle net generated power is 10.69 MW, which is the generated power by the Stirling, LNG, and Kalina turbines each by 8.07 MW, 1.13 MW, and 1.49 MW, respectively. The produced cooling load by the cooling unit of the LNG stream is also 6.09 MW, while the rate of hydrogen production in the electrolyzer is 204.77 kg/h by consuming all the generated power. Additionally, a sensitivity analysis is performed to study the effects of each design parameters on the system performance.  相似文献   

16.
A solar-wind hybrid trigeneration system is proposed and analyzed thermodynamically through energy and exergy approaches in this paper. Hydrogen, electricity and heat are the useful products generated by the hybrid system. The system consists of a solar heliostat field, a wind turbine and a thermochemical copper-chlorine (Cu-Cl) cycle for hydrogen production linked with a hydrogen compression system. A solar heliostat field is employed as a source of thermal energy while the wind turbine is used to generate electricity. Electric power harvested by the wind turbine is supplied to the electrolyzer and compressors and provides an additional excess of electricity. Hydrogen produced by the thermochemical copper-chlorine (Cu-Cl) cycle is compressed in a hydrogen compression system for storage purposes. Both Aspen Plus 9.0 and EES are employed as software tools for the system modeling and simulation. The system is designed to achieve high hydrogen production rate of 455.1 kg/h. The overall energy and exergy efficiencies of the hybrid system are 49% and 48.2%, respectively. Some additional results about the system performance are obtained, presented and discussed in the paper.  相似文献   

17.
In this research paper, comprehensive thermodynamic modeling of an integrated energy system consisting of a multi-effect desalination system, geothermal energy system, and hydrogen production unit is considered and the system performance is investigated. The system's primary fuel is a geothermal two-phase flow. The system consists of a single flash steam-based power system, ORC, double effect water–lithium bromide absorption cooling system, PEM electrolyzer, and MED with six effects. The effect of numerous design parameters such as geothermal temperature and pressure on the net power of steam turbine and ORC cycle, the cooling capacity of an absorption chiller, the amount of produced hydrogen in PEM electrolyzer, the mass flow rate of distillate water from MED and the total cost rate of the system are studied. The simulation is carried out by both EES and Matlab software. The results indicate the key role of geothermal temperature and show that both total exergy efficiency and total cost rate of the system elevate with increasing geothermal temperature. Also, the impact of changing absorption chiller parameters like evaporator and absorber temperatures on the COP and GOR of the system is investigated. Since some of these parameters have various effects on cost and efficiency as objective functions, a multi-objective optimization is applied based on a Genetic algorithm for this system and a Pareto-Frontier diagram is presented. The results show that geothermal main temperature has a significant effect on both system exergy efficiency and cost of the system. An increase in this temperature from 260 C to 300 C can increase the exergy efficiency of the system for an average of 12% at various working pressure and also increase the cost of the system by 13%.  相似文献   

18.
This paper investigates the performance of a high temperature Polymer Electrolyte Membrane (PEM) electrolyzer integrated with concentrating solar power (CSP) plant and thermal energy storage (TES) to produce hydrogen and electricity, concurrently. A finite-time-thermodynamic analysis is conducted to evaluate the performance of a PEM system integrated with a Rankine cycle based on the concept of exergy. The effects of solar intensity, electrolyzer current density and working temperature on the performance of the overall system are identified. A TES subsystem is utilized to facilitate continuous generation of hydrogen and electricity. The hydrogen and electricity generation efficiency and the exergy efficiency of the integrated system are 20.1% and 41.25%, respectively. When TES system supplies the required energy, the overall energy and exergy efficiencies decrease to 23.1% and 45%, respectively. The integration of PEM electrolyzer enhances the exergy efficiency of the Rankine cycle, considerably. However, it causes almost 5% exergy destruction in the integrated system due to conversion of electrical energy to hydrogen energy. Also, it is concluded that increase of working pressure and membrane thickness leads to higher cell voltage and lower electrolyzer efficiency. The results indicate that the integrated system is a promising technology to enhance the performance of concentrating solar power plants.  相似文献   

19.
The study examines a novel system that combined a solid oxide fuel cell (SOFC) and an organic Rankine cycle (ORC) for cooling, heating and power production (trigeneration) through exergy analysis. The system consists of an SOFC, an ORC, a heat exchanger and a single-effect absorption chiller. The system is modeled to produce a net electricity of around 500 kW. The study reveals that there is 3-25% gain on exergy efficiency when trigeneration is used compared with the power cycle only. Also, the study shows that as the current density of the SOFC increases, the exergy efficiencies of power cycle, cooling cogeneration, heating cogeneration and trigeneration decreases. In addition, it was shown that the effect of changing the turbine inlet pressure and ORC pump inlet temperature are insignificant on the exergy efficiencies of the power cycle, cooling cogeneration, heating cogeneration and trigeneration. Also, the study reveals that the significant sources of exergy destruction are the ORC evaporator, air heat exchanger at the SOFC inlet and heating process heat exchanger.  相似文献   

20.
The present study evaluates the optimal design of a renewable system based on solar and geothermal energy for power generation and cooling based on a solar cycle with thermal energy storage and an electrolyzer to produce hydrogen fuel for the combustion chamber. The subsystems include solar collectors, gas turbines, an electrolyzer, an absorption chiller, and compressed air energy storage. The solar collector surface area, geothermal source temperature, steam turbine input pressure, and evaporator input temperature were found to be major determinants. The economic analysis of the system showed that the solar subsystem, steam Rankine cycle, and compressed air energy storage accounted for the largest portions of the cost rate. The exergy analysis of the system demonstrated that the solar subsystem and SRC had the highest contributions to total exergy destruction. A comparative case study was conducted on Isfahan, Bandar Abbas, Mashhad, Semnan, and Zanjan in Iran to evaluate the performance of the proposed system at different ambient temperatures and irradiance levels during the year. To optimize the system and find the optimal objective functions, the NSGA-II algorithm was employed. The contradictory objective functions of the system included exergy efficiency maximization and cost rate minimization. The optimal Exergy round trip efficiency and cost rate were found to be 29.25% and 714.25 ($/h), respectively.  相似文献   