首页 | 官方网站   微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A dipstick dye immunoassay (DDIA) was developed to detect immunoglobulin G (IgG) or IgM antibodies of toxoplasmosis infection in humans. The assays employ a blue colloidal dye particles (D-1) conjugated to sheep anti-human IgG and rabbit anti-human IgM as the visualizing agents and a soluble antigen of tachyzoites of Toxoplasma gondii strain RH (TSA) as the detective antigen. The mixture of dye-labeled anti-human antibody-special human antibody was captured by TSA onto a nitrocellulose membrane dipstick by means of immunochromatography. The assays are rapid (the whole test can be completed within 15 min), simple, and cheap, and they don't require any equipment. They are sensitive and specific for the detection of anti-Toxoplasma IgG or IgM antibodies and generally agree closely with the results from the enzyme-linked immunosorbent assay. The assays are especially suitable for field applications.  相似文献   

2.
Two easy-to-use commercial diagnostic assays, a dipstick enzyme-linked immunosorbent assay (ELISA) (Integrated Diagnostics, Baltimore, Md.) and an immunochromatographic card assay (PanBio, Brisbane, Australia) were evaluated for detection of immunoglobulin M (IgM) antibody to dengue virus with an in-house IgM antibody capture microplate ELISA as a reference assay. The dipstick ELISA was based on the indirect-ELISA format using dengue 2 virus as the only antigen and enzyme-labeled goat anti-human IgM antibody as the detector. The total assay time was 75 min. The immunochromatographic card assay was based on the antibody capture format and separately measured both anti-dengue virus IgM and IgG in the same test. Colloidal-gold-labeled anti-dengue virus monoclonal antibody bound with dengue virus 1 to 4 antigen cocktail was the detector, and anti-human IgM and IgG were the capture antibodies. The total assay time was <10 min. Sera from 164 individuals classified as either anti-dengue virus IgM positive (94) or anti-dengue virus IgM negative (70) in the reference microplate ELISA with a dengue virus 1 to 4 antigen cocktail were tested in the two commercial assays. The dipstick ELISA missed 7 of 94 positive samples, for a sensitivity of 92.6%, while the immunochromatographic card assay missed two positive samples, for a sensitivity of 97.9%. Of the 70 negative samples, four were false positive by the dipstick ELISA and two were false positive in the immunochromatographic card assay, resulting in specificities of 94.3 and 97.1%, respectively. Both commercial assays provide sensitive and specific detection of anti-dengue virus IgM antibody and could prove useful in settings where the microplate ELISA is impractical.  相似文献   

3.
Accurate serological confirmation of dengue (DEN) infection is difficult, because simple reliable assays for the detection of DEN antibodies are not available. To address this problem, a dipstick enzyme-linked immunosorbent assay (ELISA) was evaluated. The dipstick contained dots of serially diluted DEN 2 antigen. To detect immunoglobulin G (IgG), the dipstick was processed through four reaction cuvettes containing test serum, enhancer, enzyme-conjugated anti-human IgG and IgM antibody, and substrate. Total assay time was 45 min. To detect IgM, the serum was passed through a protein G device to remove IgG. The dipstick was then processed as before, except that the incubation times were longer and enzyme-conjugated anti-human IgM was used. The total assay time was 3 h. The dipstick ELISA results were compared with results from microplate ELISA. The IgG dipstick ELISA showed a sensitivity of 95.2% and a specificity of 100% compared to an IgG microplate ELISA with serum samples from 125 individuals living in an area in which DEN is endemic. In tests with 75 serum samples from patients with clinically suspected acute DEN infections, the IgM dipstick ELISA showed a sensitivity of 97.9% and specificity of 100% compared to those of an IgM antibody capture microplate ELISA. These results showed that the dipstick ELISA was a sensitive and specific test for the detection of either DEN IgM or IgG in human serum. The dipstick ELISA was also shown to be useful for detecting seroconversions to DEN IgM or IgG in paired serum samples from 20 patients with virus isolation-confirmed acute DEN infections.  相似文献   

4.
We describe new methods for the detection of immunoglobulin G (IgG) and IgM rubella-specific antibodies in serum. The IgG assay was based on a solid-phase rubella antigen immobilization approach, and the IgM assay was based on the IgM capture assay principle. Both assays used biotinylated antibodies (anti-human IgG and antirubella monoclonal antibody, respectively). The tracer system was based on streptavidin labeled with a fluorescent europium chelate. The final measurements were done by using time-resolved fluorescence. Both assays were thoroughly evaluated with clinical samples and compared successfully with established techniques. We anticipate that these assays are suitable for routine clinical use.  相似文献   

5.
To differentiate scrub typhus from other acute febrile diseases, a rapid and reliable serological diagnosis is important. We developed an immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) for diagnosis of recent Orientia tsutsugamushi infections in humans. The 56-kDa major outer membrane protein of O. tsutsugamushi is well known as the most immunodominant antigen in scrub typhus. The test is based on the use of the biotinylated recombinant 56-kDa protein of O. tsutsugamushi Boryong, Bor56, which was expressed as a fusion protein with a maltose-binding protein in Escherichia coli. In the test, the serum IgM antibodies were captured by anti-human IgM antibodies coated onto a microtiter plate. The captured IgM antibodies were revealed through sequential addition of biotinylated Bor56 antigen and peroxidase-conjugated streptavidin to the plate. The IgM capture ELISA was compared with the immunofluorescence antibody assay (IFA) by testing 176 serum samples from patients with diagnosed cases of rickettsial disease and patients with other acute febrile diseases. Of the 81 IgG IFA-positive samples, 78 tested positive (sensitivity, 96.3%) and all 31 IgM IFA-positive samples tested positive (sensitivity, 100%) by the IgM capture ELISA. The specificity of the IgM capture ELISA was 99%, and 1 of the 95 IFA-negative samples was positive in the assay. These results strongly suggest that IgM capture ELISA using the recombinant Bor56 antigen is a reliable and detailed method for the detection of early O. tsutsugamushi infection.  相似文献   

6.
Summary Purified measles virions, nucleocapsid protein and crude lysate of measles infected cells were labelled with horseradish peroxidase, and used for the detection of IgM and IgG antibodies to measles virus by direct enzyme immunoassay. The assays consisted of three layers: anti-human IgM or IgG immunoglobulins on solid-phase, test serum specimen and enzyme labelled viral antigen. For the expression of the results, a standard curve was included in each test and the O. D. values were changed to arbitrary antibody units. Specificity and sensitivity of the assays were compared with indirect EIAs. The specificity studies included a collection of serum specimens containing either rheumatoid factor, antinuclear antibodies or IgM antibody specific for other viruses. The assays proved both reliable and simple to perform and sensitivity was slightly higher than that for indirect EIAs. However, specificity was dependent on the purity of the viral antigens. When crude infected cell lysate antigen was used, some nonspecific results were obtained, particularly with serum specimens containing antinuclear antibodies. When virion or nucleocapsid protein were used, no nonspecific reactions were obtained.With 3 Figures  相似文献   

7.
In order to develop a rapid, simple immunodiagnostic assay for schistosomiasis, soluble egg antigen (SEA) of Schistosoma japonicum was conjugated with a blue colloidal dye (D-1) produced in China and used to detect antibodies in the sera of schistosomiasis patients. The antigen-antibody complex was captured by anti-human IgG absorbed onto a nitrocellulose membrane dipstick by means of immunochromatography. The results showed that the sensitivity of the dipstick dye immunoassay (DDIA) was 96.7% in 30 cases of acute schistosomiasis (29/30) and 94.1% (79/84) in 84 cases of chronic schistosomiasis. The specificity of the assay was 96.7% in 60 healthy subjects. Cross-reactions were observed in 10.0% of 20 cases of clonorchiasis and in 70.0% of 20 cases of paragonimiasis. The results were similar to those detected by routine ELISA. In a field evaluation of the DDIA kit, the positive rate of the DDIA was 96.7% in 121 cases of schistosomiasis, compared with 90.1% with the circumoval precipitin test (COPT). The antigen conjugated with dye was stable at room temperature for at least 6 months. The results indicated that the dipstick dye immunoassay provided high sensitivity and good specificity for the detection of schistosomiasis and the assay was rapid, simple and cheap, and did not need any equipment. It was more useful for screening target populations for selective chemotherapy than other immunoassays.  相似文献   

8.
The present study aimed to evaluate the performance of three monoclonal antibodies (MAbs) in reverse enzyme-linked immunosorbent assays (ELISAs) for detecting immunoglobulin G (IgG), IgM, and IgA antibodies against Toxoplasma gondii in 175 serum samples from patients at different stages of T. gondii infection, as defined by both serological and clinical criteria, as follows: recent (n = 45), transient (n = 40), and chronic (n = 55) infection as well as seronegative subjects (n = 35). The results were compared with those obtained by indirect ELISA using soluble Toxoplasma total antigen (STAg). Our data demonstrated that MAb A3A4 recognizes a conformational epitope in SAG1-related-sequence (SRS) antigens, while A4D12 and 1B8 recognize linear epitopes defined as SAG2A surface antigen and p97 cytoplasmatic antigen, respectively. Reverse ELISA for IgG with A3A4 or A4D12 MAbs was highly correlated with indirect ELISA for anti-STAg IgG, whereas only A4D12 reverse ELISA showed high correlation with indirect ELISA for IgM and IgA isotypes. To our knowledge, this is the first report analyzing the performance of a reverse ELISA for simultaneous detection of IgG, IgM, and IgA isotypes active toward native SAG2A, SRS, and p97 molecules from STAg, using a panel of human sera from patients with recent and chronic toxoplasmosis. Thus, reverse ELISA based on the capture of native SAG2A and SRS antigens of STAg by MAbs could be an additional approach for strengthening the helpfulness of serological tests assessing the stage of infection, particularly in combination with highly sensitive and specific assays that are frequently used nowadays for diagnosis of toxoplasmosis during pregnancy or congenital infection in newborns.  相似文献   

9.
An enzyme-linked immunosorbent assay (ELISA) for the simultaneous measurement of immunoglobulin G (IgG) and IgM was developed to detect antibodies to Treponema pallidum. Wells of polystyrene microtiter plates were coated with T. pallidum antigen, diluted patient serum was added, and IgG and IgM which bound to the T. pallidum antigen were measured by the simultaneous addition of alkaline phosphatase-labeled anti-human IgG and horseradish peroxidase-labeled anti-human IgM. Bound IgG was detected first, followed by bound IgM. After development of the procedure, 145 categorized sera were evaluated: 60 from individuals without syphilis; 62 from patients with syphilis, including 22 with primary, 20 with secondary, and 20 with latent phases of syphilis; and 23 from patients with rheumatoid arthritis. Of the 60 sera from individuals without syphilis, 100% were nonreactive for IgG antibody and 16% were reactive for IgM. Of the 23 sera from patients with rheumatoid arthritis, 3 were reactive for IgG and 3 were nonreactive for IgM. Of the 62 sera from patients with syphilis, 61 (98%) were reactive for IgG antibody with increased titers as the stage of syphilis increased, whereas IgM reactivity decreased. This enzyme-linked immunosorbent assay appears to be a simple method for the simultaneous measurement of antibodies under equal assay conditions.  相似文献   

10.
An enzyme-linked immunosorbent assay (ELISA) was developed and used for the detection of IgG and IgM antibodies to West Nile virus in human sera. Thirteen paired sera of clinical cases and 24 control sera taken randomly from a blood bank repository were tested. The sera were reacted in microtiter plates coated with PEG-treated WNV antigen. IgG or IgM antibodies were quantitated by the use of alkaline-phosphatase-conjugated anti-human IgG or IgM antibodies. Of the 24 randomly collected serum samples, 7 were positive in the IgG-ELISA test. One positive by the IgM-ELISA was found to contain rheumatoid factor. In 12 of 13 paired sera of clinical cases, IgM as well as IgG antibodies were detected in the second serum sample taken about 3 wk after the onset of clinical signs. The IgM positive sera were screened for rheumatoid factor (RF) on IgG-coated plates. None of them contained RF. Antibody titers obtained by ELISA showed a good correlation with titers obtained by hemagglutination inhibition, complement fixation, and neutralization tests. The ELISA tests for detection of IgM and IgG antibodies to WNV therefore can replace the other serological methods for epidemiological surveillance and diagnostic purposes.  相似文献   

11.
The microimmunofluorescence (MIF) test is considered the “gold standard” for laboratory diagnosis of acute and chronic Chlamydia pneumoniae infection. The performance of a MIF test based on C. pneumoniae antigen from Washington Research Foundation (WRF) was compared with those of assays from Labsystems (LAB) and MRL Diagnostics (MRL) by investigation of sera from three groups of patients: group I, 83 sera from 28 patients with atypical pneumonia; group II, 37 sera from 16 patients with acute C. pneumoniae or Chlamydia psittaci respiratory tract infection confirmed by PCR or culture; group III, 100 sera from 100 persons enrolled in the Copenhagen City Heart Study. The accordance among the results of the WRF assay and the two commercial assays was excellent for the immunoglobulin M (IgM) antibody detection rate (98%). The accordance in detection rates for IgG and IgA antibodies in sera from patients with acute infections was acceptable (87 and 88%), and in sera from group III, it was excellent (95 and 97%). The determinations of endpoint titers were reproducible with <1 dilution step difference for all three methods, except that the mean IgM antibody titer found by the LAB assay was almost 2 dilution steps higher than that found by the other two methods. Although the three assays use different C. pneumoniae strains as antigens, the detection rates and IgG and IgA endpoint titers were similar. The difference in endpoint titers of IgM antibodies is of no major concern, as the diagnosis of acute C. pneumoniae infection rests on the presence of IgM antibodies, not on their level.  相似文献   

12.
A radioimmunoassay (RIA) using polystyrene beads as the solid phase for cytomegalovirus (CMV) antigen and iodinated immunosorbent purified anti-human IgG, IgM, and IgA as indicator antibodies was developed for the detection of immunoglobulin class-specific antibodies to CMV. An antigen prepared from extracellular virus was essential for reliable results, and a preparation ultracentrifuged and sonicated twice was better than a crude antigen. The optimal antigen gave low cpm values with a negative reference serum, resulting in cpm ratios of 10 or higher between early convalescent phase serum and negative reference serum. Of six patients with an increase in CMV CF titres, all six had an increase in RIA IgG titres, four had an increase in IgA titres, and all had IgM antibodies. The IgG titres were high, up to 1/64,000. In a group of 17 infants negative in CMV CF test, 14 had CMV IgG antibodies in RIA test, indicating mainly low levels of maternal antibodies. In six of seven patients with CMV isolations from urine specimens, an increase in IgG or IgA titres or the presence of IgM antibodies was found, and only one of these patients had an increase in CMV CF titre. The specificity of the developed CMV RIA test was further demonstrated by detecting no significant increase in RIA titres in serum specimens of patients with primary herpes simplex infection, chickenpox, herpes zoster, or infectious mononucleosis.  相似文献   

13.
Currently, the laboratory diagnosis of typhoid fever is dependent upon either the isolation of Salmonella enterica subsp. enterica serotype Typhi from a clinical sample or the detection of raised titers of agglutinating serum antibodies against the lipopolysaccharide (LPS) (O) or flagellum (H) antigens of serotype Typhi (the Widal test). In this study, the serum antibody responses to the LPS and flagellum antigens of serotype Typhi were investigated with individuals from a region of Vietnam in which typhoid is endemic, and their usefulness for the diagnosis of typhoid fever was evaluated. The antibody responses to both antigens were highly variable among individuals infected with serotype Typhi, and elevated antibody titers were also detected in a high proportion of serum samples from healthy subjects from the community. In-house enzyme-linked immunosorbent assays (ELISAs) for the detection of specific classes of anti-LPS and antiflagellum antibodies were compared with other serologically based tests for the diagnosis of typhoid fever (Widal TO and TH, anti-serotype Typhi immunoglobulin M [IgM] dipstick, and IDeaL TUBEX). At a specificity of > or =0.93, the sensitivities of the different tests were 0.75, 0.55, and 0.52 for the anti-LPS IgM, IgG, and IgA ELISAs, respectively; 0.28 for the antiflagellum IgG ELISA; 0.47 and 0.32 for the Widal TO and TH tests, respectively; and 0.77 for the anti-serotype Typhi IgM dipstick assay. The specificity of the IDeaL TUBEX was below 0.90 (sensitivity, 0.87; specificity, 0.76). The serological assays based on the detection of IgM antibodies against either serotype Typhi LPS (ELISA) or whole bacteria (dipstick) had a significantly higher sensitivity than the Widal TO test when used with a single acute-phase serum sample (P < or = 0.007). These tests could be of use for the diagnosis of typhoid fever in patients who have clinical typhoid fever but are culture negative or in regions where bacterial culturing facilities are not available.  相似文献   

14.
An indirect ELISA system was designed for quantitation of human blood group A and B IgM and IgG antibodies. The capturing antigens are blood group substance A or B used to sensitize polystyrol microtiter plates. Bound anti-A or anti-B antibodies are revealed either directly, by development with polyclonal anti-human immunoglobulin class-specific conjugate or with more avid mouse monoclonal anti-human isotype antibodies revealed in turn by goat anti-mouse conjugate. Reproducibly, 100 ng specific anti-A IgG provided for a significant above-background signal of 0.2 at OD405 and 15 serum samples had a mean content of 3.98 +/- 8.74 micrograms (mean +/- 2 SD) (range: 0.305-12.62) of specific anti-A IgG/g total IgG. Thus one molecule specific anti-A IgG is found per 7.9 X 10(4)-3.2 X 10(6) total IgG molecules. Statistical correlations were significant between anti-A IgG levels and agglutination titer (P less than 0.05) but non-significant when the specific anti-A IgG levels of individual serum samples were compared to their total IgG content (P greater than 0.05). Dose-response signals were similar for anti-A and anti-B IgM antibodies. Reproducibility of the assay was excellent. Specificity was ascertained by various approaches involving development of primary antibodies with heterospecific antibody conjugate and adsorption of primary antibody from serum using A and B group erythrocytes or soluble A and B substances. Separation of IgM from IgG anti-A antibodies over sizing gel resulted in fractions that were immunosorbed by mouse monoclonal anti-human IgM and IgG respectively but not vice versa.  相似文献   

15.
Current techniques for the measurement of BK papovavirus (BKV) specific IgM include sucrose density gradient centrifugation followed by hemagglutination inhibition (HAI) or indirect immunofluorescent (IF) staining of BKV infected cells using a fluorescein conjugated anti-human IgM antibody. These techniques are cumbersome and labor intensive and do not lend themselves to testing large numbers of sera. A solid phase radioimmunoassay (RIA) was developed to facilitate the measurement of BKV IgG and IgM in large numbers of sera. Solid phase antigen was prepared by adsorbing CsCl purified BKV antigen to polyvinyl chloride microtiter plates. Following reaction with serum, bound immunoglobulin was detected with iodinated goat anti-human IgG or IgM. RIA for the measurement of BKV IgG was sensitive with titers approaching 10−6. Determination of IgG titers by RIA and HAI showed good agreement (P < 0.01, correlation coefficient = 0.74). Measurement of BKV IgM was not affected by the presence of BKV IgG as evidenced by sucrose density gradient fractionation of IgM positive sera, removal of IgG by treatment with S. aureus protein A, and addition of BKV IgG to BKV IgM. Rheumatoid factor (RF) gave false positive IgM titers in the presence of BKV IgG when RF titers were ≥ 1:640 by latex agglutination testing and BKV IgG levels exceed 1:256 by HAI. False positives due to RF could be eliminated by treatment of sera with sheep anti—human IgG antisera. RIA for BKV IgM was specific as sera containing JCV-, cytomegalovirus (CMV)-, rubella-, or hepatitis B core antibody (anti HBc)—IgM were negative by RIA. RIA detected BKV IgM in several sera from renal dialysis or allograft palienls with titers ranging from 1:400 to 1:128,000 and demonstrated that BKV IgM persisted in sera of renal allograft patients for as long as 343 days post transplantation.  相似文献   

16.
The immunoassay method in which 125I-labeled staphylococcal Protein A ([125I]PA) serves as a general tracer has been extended to include goat and sheep IgG antibodies. Goat and sheep IgG normally do not react significantly with PA. However, once IgG antibody is bound to immobilized antigen or hapten, binding of [125I]PA is enhanced markedly. Binding efficiencies of [125I]PA to immune complexed goat anti-human IgM, human IgE, methotrexate and sheep anti-IgE were determined and compared quantitatively to rabbit IgG with the corresponding specificity. Immunoassays were developed based on the inhibition of [125I]PA binding as a measure of antibody inhibition by fluid-phase homologous ligand. In terms of sensitivity and specificity, assays using goat and sheep antibodies were comparable to assays developed using rabbit IgG. Goat antibody to the monovalent hapten methotrexate behaved anomalously: for each concentration of IgG tested, there was an optimal amount of methotrexate beads that gave maximum binding of [125I]PA. In the other immune systems, for each antibody concentration maximum binding of tracer was a function only of the amount of immobilized antigen added. In contrast to the results obtained with solid-phase antigen, solutions containing antibody and amounts of antigen ranging from large antigen excess to antibody excess to antibody excess failed to react significantly with PA or [125I]PA.  相似文献   

17.
The risk of obtaining false-negative results in serological assays in serum and CSF specimens with only one strain of Borrelia burgdorferi sensu lato as antigen was investigated in 79 patients with neuroborreliosis with specimens obtained at initial presentation. Serum antibodies were assessed by immunoblotting; the criteria of Hauser et al. were used to evaluate the test. The intrathecal synthesis of borrelial-specific IgM and IgG antibodies was examined by enzyme immunoassay (EIA). Strains of B. burgdorferi sensu stricto (BbZ160), B. garinii (Bbii50) and B. afzelii (PKO) served as sources of antigen in both assays. All patients produced either a positive IgM or IgG test in serum with at least one strain of B. burgdorferi sensu lato. Reactivity of IgM or IgG antibodies, or both, with antigens of all three strains was demonstrated in 67 (85%) of 79 sera. The correlation of results of immunoblotting with different strains was significantly better for IgG (85%) than for IgM antibodies (54%). The variability of positive IgM reactions in 18 specimens was mainly due to the fact that the antibodies were directed to the relevant variable outer-surface protein C (p23). Intrathecal synthesis of IgG antibodies was demonstrated in 58 patients (81%) of 72 and of IgM antibodies in 25 of 58 patients. No patient had isolated intrathecal synthesis of IgM antibodies. The majority of CSF samples (56 of 58) were assessed as IgG antibody-positive, independent of the borrelial strain used as antigen in EIA, whereas only 10 of 25 IgM antibody-positive CSF specimens reacted with all three strains. All patients in the study had intrathecal antibody synthesis demonstrable at 6-week follow-up. From this study it is concluded that there is a small, but real, risk of false-negative serological findings at the time of initial clinical presentation in patients with typical symptoms of neuroborreliosis. In these patients a negative serological result with one strain should prompt the repetition of the test with other strains of B. burgdorferi sensu lato.  相似文献   

18.
The effect of IgM and IgG antibodies on the primary response to Salmonella typhi antigen has been studied. IgG antibodies given before antigenic challenge or combined with antigen in antibody excess profoundly suppressed the formation of agglutinins in rabbits and humans. IgM antibodies appeared to have little or no inhibitory effect when given as complexes in antibody excess or when infused in relatively small amounts. Larger amounts do inhibit agglutinin formation in rabbits. It is suggested that the antibodies exert their inhibitory effect by combining with antigen and removing it as a stimulant for antibody formation.  相似文献   

19.
Here we report standardization of a dipstick enzyme-linked immunosorbent assay (ELISA, Dipstick ELISA) and its comparative evaluation with a commercial Rapid PanBio Immunochromatographic test (IC test) for detection of Dengue (DEN) virus-specific IgM and IgG antibodies in patient sera. Among crude and purified viral antigens prepared from mouse brains or cell cultures, a DEN virus type 2 antigen purified from cell cultures by sucrose density gradient centrifugation was found superior in terms of the signal/ noise (S/N) ratio in the assay system. The sensitivity of detection of the virus by specific IgM antibody was improved by removal of IgG from patient sera prior to testing. The evaluation of the Dipstick ELISA by use of 156 serum samples revealed an overall accordance of 96% and 93% with the IC test in detection of IgM antibodies to DEN viruses (IgM antibodies) and IgG antibodies to DEN viruses (IgG antibodies), respectively. The sensitivity of the Dipstick ELISA and the IC test with reference to the mu-capture ELISA was 83% and 87%, respectively, with a specificity of 98% in both cases. The sensitivity of the Dipstick ELISA with reference to the IC test in detecting IgM and IgG antibodies was 84% and 94%, respectively, and the specificity of the Dipstick ELISA was 98% and 92%, respectively.  相似文献   

20.
Dengue has become hyperendemic in many islands of the Caribbean region. The performance in a diagnostic laboratory of four commercial assays for detection of immunoglobulin M (IgM) antibodies was evaluated. Sera from 62 patients with dengue virus infection were studied. These included 18 patients from whom dengue virus type 2 was isolated in a 1997 outbreak (specimens collected a mean of 14 days after onset of symptoms), 8 patients with dengue hemorrhagic fever (mean time after onset, 11 days), and 36 patients in whom dengue was previously confirmed by serology (mean time after onset, 10 days). Thirty serum specimens from blood donors in a country where dengue is not endemic were used as negative controls. The methods evaluated were two IgM-capture enzyme-linked immunosorbent assays (ELISA) (MRL Diagnostics, Cypress, Calif., and PanBio, Queensland, Australia), a dot ELISA dipstick assay (Integrated Diagnostics, Baltimore, Md.), and a rapid immunochromatographic assay for dengue IgG and IgM (PanBio IC). IgG antibodies were also detected by an ELISA method (MRL Diagnostics). The sensitivities of the four assays were as follows: MRL Diagnostics IgM ELISA, 98.4%; PanBio IgM ELISA, 85.5%; Integrated Diagnostics IgM dot ELISA, 96. 8%; and PanBio IC, 83.9%. The specificities of all tests were 100%. Evidence of secondary dengue was found in all patients with dengue hemorrhagic fever and in 83% of the remaining patients. The MRL Diagnostics IgM ELISA appears to be more sensitive than the PanBio IgM ELISA, and this may be significant when IgM titers are low, particularly in patients with secondary dengue infections. The dot ELISA dipstick assay is equally sensitive and may be more appropriate for use in laboratories with lower workloads.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号