1.
一种新型全铝扁盒式PV/T热水系统   总被引:3,自引:0,他引:3  
将单晶硅光伏电池与全铝扁盒式太阳能热水器集热板通过特殊工艺粘结起来,制成了一套自然循环式光伏光热一体化(PV/T)系统,在利用太阳能发电的同时提供热水。于04年7月-10月在合肥地区进行了室外实验,测试并讨论了该系统以不同水量和不同初始水温运行时的光电光热性能。结果表明,当m/Ac>80kg/m2时,这种PV/T热水系统的发电效率在10.15%左右,热效率在50%左右,光电光热总效率可以达到60%左右,光电光热综合性能效率可以达到70%左右。相对于单纯的光伏系统或自然循环式太阳能热水系统,这种PV/T热水系统具有占地面积小、综合效率高等优点。  相似文献   

2.
The electrical efficiency of a photovoltaic system drops as its operating temperature rises and PV cooling is necessary. The photovoltaic/thermal (PV/T) system is a relatively recent type of solar collector where a circulating fluid of lower temperature than PV module extracts heat from it, cooling the module to improve its output power while the solar pre-heated fluid provides sensible heat. In the present work, air cooling of a commercial PV module configured as PV/T air solar collector by natural flow is presented, where two low cost modification techniques to enhance heat transfer to air stream in the air channel are studied. The considered methods consist of thin metal sheet suspended at the middle or fins attached to the back wall of the air-channel to improve heat extraction from the module. A numerical model was developed and validated against the experimental data obtained from outdoor test campaigns for both glazed and unglazed PV/T prototype models studied. The validation results show good agreement between predicted values and measured data and thus could be used to study analytically the performance of these PV/T air collectors with respect to several design and operating parameters. The modified systems present better performance than the usual type and will contribute to better performance of integrated PV systems for natural ventilation applications in buildings, both space cooling and heating.  相似文献   

3.
Performance evaluation of solar photovoltaic/thermal systems   总被引:6,自引:0,他引:6  
The major purpose of the present study is to understand the performance of an integrated photovoltaic and thermal solar system (IPVTS) as compared to a conventional solar water heater and to demonstrate the idea of an IPVTS design. A commercial polycrystalline PV module is used for making a PV/T collector. The PV/T collector is used to build an IPVTS. The test results show that the solar PV/T collector made from a corrugated polycarbonate panel can obtain a good thermal efficiency. The present study introduces the concept of primary-energy saving efficiency for the evaluation of a PV/T system. The primary-energy saving efficiency of the present IPVTS exceeds 0.60. This is higher than for a pure solar hot water heater or a pure PV system. The characteristic daily efficiency ηs* reaches 0.38 which is about 76% of the value for a conventional solar hot water heater using glazed collectors (ηs*=0.50). The performance of a PV/T collector can be improved if the heat-collecting plate, the PV cells and the glass cover are directly packed together to form a glazed collector. The manufacturing cost of the PV/T collector and the system cost of the IPVTS can also be reduced. The present study shows that the idea of IPVTS is economically feasible too.  相似文献   

4.
将太阳能电池板、集热器、热电发电片结合起来,设计并制成了一套光伏/热电(PV/TV)系统,在利用太阳能电池发电的同时,收集热量并利用其发电。在北京地区进行了该系统的室外模拟试验,测试并讨论了该系统在不同结构和不同环境下的性能,探讨该系统在光伏建筑中的应用。试验结果表明,与单纯的光伏发电系统或太阳能热水系统相比,PV/TV系统具有占地面积小、综合效率高等优点。  相似文献   

5.
在太阳能光伏热系统中,光伏电池温度过高会导致太阳能发电效率下降。相变微胶囊悬浮液(MEPCMS)是一种潜热型功能性流体,将其作为冷却介质用于太阳能光伏热系统可以有效降低光伏电池温度,提高系统的能量利用率。针对相变微胶囊易泄露、导热性差等问题提出了改性方法,使其具有光热转换功能并提升了综合性能。基于性能评价指标分析了太阳能光伏热系统性能的影响因素。结果发现,流速、浓度和太阳辐照量是影响MEPCMS在太阳能光伏热系统中换热性能的关键因素。适当增加MEPCMS浓度和流速能提高工质的换热性能,在降低光伏板温度的同时增加太阳辐照量和系统热电产量,但需结合太阳辐照量大小合理匹配工质的浓度和流速。未来研究方向可集中在提升MEPCMS在太阳能光伏热系统中的换热性能、探究运行参数和太阳辐照量之间的匹配关系、优化集热器结构、利用其蓄热性解决太阳能间歇性等方面。  相似文献   

6.
Electric energy production with photovoltaic (PV)/thermal solar hybrid systems can be enhanced with the employment of a bifacial PV module. Experimental model of a PV/thermal hybrid system with such a module was constructed and studied. To make use of both active surfaces of the bifacial PV module, we designed and made an original water-heating planar collector and a set of reflecting planes. The heat collector was transparent in the visible and near-infrared spectral regions, which makes it compatible with the PV module made of crystalline Si. The estimated overall solar energy utilization efficiency for the system related to the direct radiation flux is of the order of 60%, with an electric efficiency of 16.4%.  相似文献   

7.
A polymer solar heat collector was combined with single-crystal silicon PV cells in a hybrid energy-generating unit that simultaneously produced low temperature heat and electricity. The PV/T unit was tested experimentally to determine its thermal and photovoltaic performance, in addition to the interaction mechanisms between the PV and thermal energy systems. Thermal efficiency measurements for different collector configurations are compared, and PV performance and temperature readings are presented and discussed. An analytical model for the PV/T system simulated the temperature development and the performance of both the thermal and photovoltaic units.  相似文献   

8.
The Photovoltaic/thermal(PV/T) system combines the conventional PV panel with solar collector into one integrated system, which could achieve the function of generating power and providing thermal energy at the same time. Recently, it has become the most promising solar system for building applications. Most of the PV/T systems use water as the coolant, which could cause freezing problem in winter. To overcome this problem, the heat pipe PV/T system is developed to provide electrical and thermal energy stably without the seasonal barrier. Although some published review works have involved this type of PV/T system, they just stated a simple introduction on it, acting as a small part of their works. This paper focuses on the heat pipe PV/T system independently and provides a comprehensive and in-depth analysis of its performance. Firstly, the structure and operational principles of the heat pipe PV/T module and system are introduced concisely. Then the features and performance of different types of heat pipe PV/T systems, i.e., integral heat pipe, loop heat pipe, and pulsating heat pipe PV/T system, are presented and analyzed. This is followed by the review on the performance of the systems which combine heat pipe PV/T module and other devices. Finally, the research gaps in this field are identified, and some future research trends and directions are recommended.  相似文献   

9.
对直接膨胀式太阳能热泵热水系统进行了实验研究,实验期间,太阳能辐照度变化范围为143.12~664.6 W/m2,分别采用三种不同结构的集热器和蒸发器,得出系统COP为2.49~3.47,表明该系统在各种天气情况下均能够可靠地生产45℃的生活热水,热性能稳定,可以全天候地提供生活热水且具有节能效果;同时选取双集热器的两组数据,分析了太阳辐照度对热泵系统运行的影响。  相似文献   

10.
In this paper, an attempt is made to evaluate the thermal performance of a hybrid photovoltaic thermal (PV/T) air collector system. The two type of photovoltaic (PV) module namely PV module with glass-to-tedlar and glass-to-glass are considered for performance comparison. The results of both PV modules are compared for composite climate of New Delhi. Analytical expression for solar cell, back surface, outlet air temperatures and an overall thermal efficiency are derived for both cases. It is observed that hybrid air collector with PV module glass-to-glass gives better performance in terms of overall thermal efficiency. Parametric studies are also carried out.  相似文献   

11.
In this paper, the optimization of a solar photovoltaic thermal (PV/T) water collector which is based on exergy concept is carried out. Considering energy balance for different components of PV/T collector, we can obtain analytical expressions for thermal parameters (i.e. solar cells temperature, outlet water temperature, useful absorbed heat rate, average water temperature, thermal efficiency, etc.). Thermal analysis of PV/T collector depends on electrical analysis of it; therefore, five-parameter current–voltage (IV) model is used to obtain electrical parameters (i.e. open-circuit voltage, short-circuit current, voltage and current at the point which has maximum electrical power, electrical efficiency, etc.). In order to obtain exergy efficiency of PV/T collector we need exergy analysis as well as energy analysis. Considering exergy balance for different components of PV/T collector, we obtain the expressions which show the exergy of the different parts of PV/T collector. Some corrections have been done on the above expressions in order to obtain a modified equation for the exergy efficiency of PV/T water collector. A computer simulation program has been developed in order to obtain the amount of thermal and electrical parameters. The simulation results are in good agreement with the experimental data of previous literature. Genetic algorithm (GA) has been used to optimize the exergy efficiency of PV/T water collector. Optimum inlet water velocity and pipe diameter are 0.09 m s−1, 4.8 mm, respectively. Maximum exergy efficiency is 11.36%. Finally, some parametric studies have been done in order to find the effect of climatic parameters on exergy efficiency.  相似文献   

12.
In this technical article, a novel experimental setup is designed and proposed to produce a hydrogen by using solar energy. This system comprises a hybrid or photovoltaic Thermal (PVT) solar collector, Hoffman's voltameter, heat exchanger unit and Phase Change Material (PCM). The effect of PCM and mass flow rate of water on the hybrid solar collector efficiency and hydrogen yield rate is studied. This experimental results clearly showed that by adding the thermal collector with water, decreases PV module temperature by 20.5% compared with conventional PV module. Based on the measured values, at 12.00 and 0.011 kg/s mass flow rate, about 33.8% of thermal efficiency is obtained for water based hybrid solar collector. Similarly, by adding Paraffin PCM to the water based thermal collector, the maximum electrical efficiency of 9.1% is achieved. From this study, the average value of 17.12% and 18.61% hydrogen yield rate is attained for PVT/water and PVT/water with PCM systems respectively.  相似文献   

13.
Photovoltaic-thermal collectors (or PV-T collector) are hybrid collectors where PV modules are integrated as an absorber of a thermal collector in order to convert solar energy into electricity and usable heat at the same time. In most of the cases, the hybrid collectors are made by the superposition of a PV module on the thermal absorber of a solar collector. In this paper, the approach is different and is to analyze thermal and optical properties related to both PV and solar thermal functions in order to identify an optimum combination leading to a maximum overall efficiency. Indeed, although these two functions do not exploit the same range of radiation wavelengths, thermal and PV functions are not so complementary due to photo-conversion thermal dependency. In this context, an alternative PV cell lamination has been developed with increased optical and thermal performance. The improvements were evaluated around 2 mA/cm2 in terms of current density in comparison to a standard module encapsulation. Based on this technique, a real size PV-T module has been built and tested at Fraunhofer solar test facilities. The results show a global efficiency of the PV-T collector above 87% (79% thermal efficiency plus 8.7% electrical efficiency, based on the absorber area).  相似文献   

14.
This paper presents an improved design of a photovoltaic/thermal (PV/T) solar collector integrating a PV panel with a serpentine-shaped copper tube as the water heating component and a single pass air channel as the air heating component. In addition to the electricity generated, this type of collector enables the production of both hot air and water, increasing the total efficiency per unit area compared to the conventional PV/T solar collector. The use of both fluids (bi-fluid) also creates a greater range of thermal applications and offers options in which hot and/or cold air and/or water can be utilized depending on the energy needs and applications. In this paper, the design concept of the bi-fluid PV/T solar collector is emphasized with 2D steady state energy balance equations for the bi-fluid configuration are developed, validated and used to predict the performance of the bi-fluid solar collector for a range of mass flow rates of air and water. The performance of the collector is then compared when the fluids are operated independently and simultaneously. The simulations indicate that when both fluids are operated independently the overall thermal and electrical performance of the solar collector is considered as satisfactory and when operated simultaneously the overall performance is higher. The bi-fluid PV/T solar collector discussed in this paper will add insights to the new knowledge of optimizing the utilization of solar energy by a PV/T solar collector and has potential applications in various fields.  相似文献   

15.
A novel heat pump system is proposed in that the PV/T collector is coupled with a solar assisted heat pump and works as an evaporator. The cooling effect of the refrigerant allows the PV modules to work at lower temperature and so its photovoltaic efficiency is improved. Mathematical model has been developed to analyze the complex energy conversion processes. Numerical simulation was then performed based on the distributed parameters approach. An experimental rig was also built to verify the real performance of the system as compared to the simulation model prediction. The results indicated that this photovoltaic solar assisted heat pump (PV-SAHP) has better coefficient of performance (COP) and photovoltaic efficiency than the separate units. Under the experimental conditions, the COP of the PV-SAHP reached 8.4 and the average value was around 6.5, whereas the average photovoltaic efficiency was around 13.4%. The experimental results were found in good agreement with the theoretical predictions on the system responses to changing environmental conditions.  相似文献   

16.
文章设计了新型非晶硅太阳能PV/T空气集热器,该空气集热器能够解决传统太阳能PV/T热水器在高温波动情况下,晶硅电池热应力大的问题,同时避免了冬季管道发生霜冻的现象。文章通过实验对比,分析了非晶硅太阳能PV/T空气集热器、单独非晶硅光伏电池和传统太阳能空气集热器的能量效率和[火用]效率的差异。分析结果表明:非晶硅太阳能PV/T空气集热器的平均热效率为45.70%,比传统太阳能空气集热器的平均热效率降低了约25.88%;当空气质量流量增大至0.048 kg/s时,非晶硅太阳能PV/T空气集热器中的非晶硅光伏电池的平均电效率高于单独非晶硅光伏电池,它们的平均电效率分别为4.70%,4.54%;非晶硅太阳能PV/T空气集热器的总[火用]效率高于传统太阳能空气集热器的热[火用]效率和单独非晶硅光伏电池的电[火用]效率,非晶硅太阳能PV/T空气集热器总[火用]效率最大值为7.14%。文章的分析结果为非晶硅太阳能PV/T空气集热器的推广提供了参考。  相似文献   

17.
G. Fraisse  C. Mnzo  K. Johannes 《Solar Energy》2007,81(11):1426-1438
The integration of photovoltaic (PV) modules in buildings allows one to consider a multifunctional frame and then to reduce the cost by substitution of components. In order to limit the rise of the cell operating temperature, a photovoltaics/thermal (PV/T) collector combines a solar water heating collector and PV cells. The recovered heat energy can be used for heating systems and domestic hot water. A combination with a Direct Solar Floor is studied. Its low operating temperature level is appropriate for the operating conditions of the mono- or poly-crystalline photovoltaic modules which are selected in that study. However, for a system including a glass covered collector and localised in Mâcon area in France, we show that the annual photovoltaic cell efficiency is 6.8% which represents a decrease of 28% in comparison with a conventional non-integrated PV module of 9.4% annual efficiency. This is obviously due to a temperature increase related to the cover. On the other hand, we show that without a glass cover, the efficiency is 10% which is 6% better than a standard module due to the cooling effect.Moreover, in the case of a glazed PV/T collector with a conventional control system for Direct Solar Floor, the maximum temperature reached at the level of the PV modules is higher than 100 °C. This is due to the oversize of the collectors during the summer when the heating needs are null, i.e. without a heated swimming pool for example. This temperature level does not allow the use of EVA resin (ethylene vinyl acetate) in PV modules due to strong risks of degradation. The current solution consists of using amorphous cells or, if we do not enhance the thermal production, uncovered PV/T collector. Further research led to water hybrid PV/T solar collectors as a one-piece component, both reliable and efficient, and including the thermal absorber, the heat exchanger and the photovoltaic functions.  相似文献   

18.
This article presents an overview on the research and development and application aspects for the hybrid photovoltaic/thermal (PV/T) collector systems. A major research and development work on the photovoltaic/thermal (PVT) hybrid technology has been done since last 30 years. Different types of solar thermal collector and new materials for PV cells have been developed for efficient solar energy utilization. The solar energy conversion into electricity and heat with a single device (called hybrid photovoltaic thermal (PV/T) collector) is a good advancement for future energy demand. This review presents the trend of research and development of technological advancement in photovoltaic thermal (PV/T) solar collectors and its useful applications like as solar heating, water desalination, solar greenhouse, solar still, photovoltaic-thermal solar heat pump/air-conditioning system, building integrated photovoltaic/thermal (BIPVT) and solar power co-generation.  相似文献   

19.
The photovoltaic thermal collector can provide thermal and heat power at the same time.In this paper, a photovoltaic/thermal sheet and tube collector has been numerically investigated. The paper focuses on the development of a hybrid solar collector PV/T. This model will be applied to optimize the operation of the PVT collector in the semi-arid climate. A mathematical model has been developed to determine the dynamic behavior of the collector, based on the energy balance of six main components namely a transparent cover, a PV module, a plate absorber, a tube, water in the tube and insulation. It has been validated by comparing the obtained simulation results with experimental results available in literature, where good agreement has been noted. Using our developed model, the heat and electrical power of sheet and tube collector has been analyzed for four typical days of year with the meteorological parameters of Monastir, Tunisia. Furthermore, the effect of solar radiation, the inlet water temperature, the number of glazing covers and the conductive heat transfer coefficient between plate absorber and PV module have been involved to identify their influence on the thermal and electrical efficiencies. The monthly thermal and electrical energies is also evaluated.  相似文献   

20.
The thermal performance of two different schemes of solar‐assisted heat‐pump systems has been theoretically studied. In first scheme, the evaporator of the heat pump is taken directly as the solar collecting plate and always maintained at the ambient temperature. As there is no heat loss from the collecting plate, the thermal efficiency of the collector is high and equals the solar absorptivity of the collecting plate. As suggested, the heat‐pump evaporator of the second scheme is placed in a novel fresh water solar pond/tank with high efficiency. Since the evaporator operates at a relatively high temperature, the COP of the heat pump can be increased. The calculated results show that the COP of a solar‐assisted heat pump using the second scheme is considerably higher than that of the first scheme. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   