首页 | 官方网站   微博 | 高级检索  
     


Influence of bone mineral density on pedicle screw fixation : a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients
Authors:Koichiro Okuyama MD   Eiji Abe MD   Tetsuya Suzuki MD   Yasuki Tamura MD   Mitzuho Chiba MD  Kozo Sato MD
Affiliation:Department of Orthopedic Surgery, Akita Rosai Hospital, Karuizawa Aza Shimotai, 30 Odate City, Akita 018-5604, Japan. gonn@cocoa.ocn.ne.jp
Abstract:BACKGROUND CONTEXT: Some biomechanical studies have demonstrated that bone mineral density of the lumbar spine (BMD) affects the stability of pedicle screws in vitro. PURPOSE: To investigate influence of BMD on loosening and related failure of pedicle screws in vivo. STUDY DESIGN/SETTING: A clinical study of 52 patients who underwent pedicle screw fixation augmenting posterior lumbar interbody fusion (PLIF). PATIENT SAMPLE: There were 13 men and 39 women, with an average age of 63 years (range, 45-76 years) at the time of operation. The mean follow-up period was 2.8 years (range, 2-6 years). OUTCOME MEASURES: Relationship between BMD, screw loosening, and its related failures were statistically analyzed. METHODS: BMD was measured by the dual energy X-ray absorptiometry (DEXA) method. Radiographic assessments were done by the first author and independently by another orthopedist who was not informed of the values of BMD. RESULTS: The mean BMD of all patients was 0.879 +/- 0.215 (mean +/- S.D.) g/cm2. The mean BMD in patients with and without screw loosening was 0.720 +/- 0.078 g/cm2 (n=11) and 0.922 +/- 0.221 g/cm2 (n=41). There was a significant difference between the mean BMD of patients with and without screw loosening (P<.01). The mean BMD of patients with "union," "nonunion" and "undetermined union" was 0.934 +/- 0.210 g/cm2 (n=40), 0.674 +/- 0.104 g/cm2 (n=4) and 0.710 +/- 0.116 g/cm2 (n=8), respectively. The mean BMD of patients with "union" was significantly greater than those with "nonunion" and "undetermined union" (P<.05). CONCLUSION: It could be concluded that BMD has a close relation with the stability of pedicle screws in vivo, and BMD value below 0.674 +/- 0.104 g/cm2 suggests a potential increased risk of "nonunion" when pedicle screw fixation is performed in conjunction with PLIF.
Keywords:Pedicle screw   Posterior lumbar interbody fusion (PLIF)   Screw loosening   Nonunion   Bone mineral density (BMD)
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号