首页 | 官方网站   微博 | 高级检索  
     

高湿度高山风电场的防雷接地设计
引用本文:杜华.高湿度高山风电场的防雷接地设计[J].红水河,2014(3):16-18.
作者姓名:杜华
作者单位:广西电力工业勘察设计研究院,广西南宁530023
摘    要:针对亚热带季风湿润气候区高山风电场,冬季气温低、太阳辐射小,空气湿度大、霜雪期长、冻雨灾害严重、雷暴日多等特点,对风力发电机组、箱式变压器的防雷接地设计谈谈工作体会,经验可供同类风电场设计人员参考。

关 键 词:高山风电场  防雷接地

Lightning Protection and Grounding Design for High Humidity Mountain Wind Farm
DU Hua.Lightning Protection and Grounding Design for High Humidity Mountain Wind Farm[J].Hongshui River,2014(3):16-18.
Authors:DU Hua
Affiliation:DU Hua (Guangxi Electric Power Industry Investigation Design and Research Institute, Nanning, Guangxi, 530023)
Abstract:The paper makes a discussion on the lightning protection and grounding design for wind generating sets and box-type transformer based on the characteristics of high mountain wind farm in subtropical humid monsoon cli- mate area, such as low temperatures in winter, small solar radiation, great air humidity, long frost period, severe freez- ing rain disaster and many thunderstorm days, which can be well referenced by similar wind farm projects.
Keywords:high mountain wind farm  lightning protection and grounding
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号