首页 | 官方网站   微博 | 高级检索  
     

四种螺纹截面形态对种植体初期稳定性影响的三维有限元研究
引用本文:马攀,李德华,刘杰,林升,彭勤建,李双发,李万年,张宪梅.四种螺纹截面形态对种植体初期稳定性影响的三维有限元研究[J].中华医学美学美容杂志,2008,14(3).
作者姓名:马攀  李德华  刘杰  林升  彭勤建  李双发  李万年  张宪梅
作者单位:1. 黄寺美容外科医院口腔科,北京,100011
2. 第四军医大学秦都口腔医院种植科
3. 总参管理局中心门诊部口腔科
摘    要:目的 利用即刻负载有限元模型研究种植体不同螺纹截面类型因素对初期稳定性的影响.方法 利用Pro/E软件、Hypermesh 7.0软件及ABAQUS 6.5有限元软件,建立4类种植体即刻负载的三维有限元模型,比较4种螺纹截面形态(V型,支撑型, 矩型和反支撑型)在分别垂直和水平加载时对种植体初期稳定性的影响.结果 对不同螺纹截面形态种植体的微动程,垂直加载时支撑型螺纹种植体微动最小,反支撑型螺纹种植体微动最大,水平加载时反支撑型螺纹种植体微动最小,支撑型螺纹种植体微动最大.结论 螺纹截面的形态和强度对垂直相对位移有影响, 对颊舌相对位移影响不大,螺纹顶边和底边与种植体体部的角度越大,抵抗垂直向的能力越强,但强度差,因此在螺纹种植体设计时,要兼顾螺纹截面角度和强度.

关 键 词:螺纹型牙种植体  即刻负载  三维有限元  微动  初期稳定性

Influence of four kinds of thread design on the primary stability of immediately loaded dental implants
MAN Pan,LI De-hua,LIU Jie,LIN Sheng,PENG Qin-jian,LI Shuang-fa,LI Wan-nian,ZHANG Xian-mei.Influence of four kinds of thread design on the primary stability of immediately loaded dental implants[J].Chinese Journal of Medical Aesthetics and Cosmetology,2008,14(3).
Authors:MAN Pan  LI De-hua  LIU Jie  LIN Sheng  PENG Qin-jian  LI Shuang-fa  LI Wan-nian  ZHANG Xian-mei
Abstract:Objective To discuss the effects of implants of different thread face angles on the primary stability of immediately loaded implant using the 3-dimensional finite element analysis with the models of the immediately loaded implants. Methods Using the commercial code of Pro/E software, Hypermesh software, and ABAQUS software we created 3-dimensional finite element models. The micromotions of the finite element models with different screw face angles (V-shape, buttress, square-shape and inverse buttress) were computed with the ABAQUS software. Results Concerning different thread face angles, the micromotion of buttress implant was the minimum and the micromotion of inverse buttress implant was the maximum with vertically loading; the micromotion of inverse buttress implant was the minimum and the micromotion of buttress implant was the maximum with horizontal loading. Conclusions Different screw-types have great influence on vertical interfacial micromotions but little influence on horizontal interfacial micromotions. There are two angles which are formed by top /bottom edge and the implants. The larger are the angles, the smaller are the vertical interfacial micromotions, but the weaker of the strength. Thus in designing the screw-type implants, we should consider the angles of thread faces and the strength.
Keywords:Screw-type Implants  Immediate loading  Three-dimensional finite element analysis  Micromotion  Primary implant stability
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号