首页 | 官方网站   微博 | 高级检索  
     

金沉积复合镍铬合金烤瓷的镍离子析出量的实验研究
引用本文:刘峰,孙凤,毛红,李亚丽,程海明,陈吉文. 金沉积复合镍铬合金烤瓷的镍离子析出量的实验研究[J]. 中华口腔医学杂志, 2008, 43(3): 182-184
作者姓名:刘峰  孙凤  毛红  李亚丽  程海明  陈吉文
作者单位:1. 北京大学口腔医学院·口腔医院第一门诊部特诊科,100034
2. 北京大学口腔医学院·口腔医院义齿加工中心,100034
3. 北京钢铁研究总院分析测试所
摘    要:目的 通过测试浸泡在人工唾液中的金沉积片复合镍铬合金片烤瓷试件的镍离子析出量,探究金沉积基底冠熔结镍铬桥体烤瓷桥是否能减少镍离子析出,降低生物安全风险.方法 将镍铬合金片与金沉积片粘接,表面烤瓷,瓷层厚度分别为0.3 mm(A组)、0.5 mm(B组)、1.0 mm(C组)和0.3 mm(D组),每组6个试件.对照组为镍铬合金片.A、B、C组和对照组浸泡在37℃酸性人工唾液中;D组浸泡在37℃酸性高氟人工唾液中.浸泡120 h后,测定浸泡液的镍离子浓度.独立样本t检验比较A~D组浸泡液镍离子浓度与对照组的差异.结果 A、B、C、D组的镍离子浓度均小于0.005 mg/L;与对照组[(0.65±0.45)mg/L]相比,差异均有统计学意义(P<0.05).结论 金沉积基底冠熔结镍铬桥体烤瓷桥可减少镍离子析出,降低生物安全风险.

关 键 词:金属烤瓷合金  铬合金  

Quantity of released nickel ion from Ni-Cr alloy of compound galvano-ceramic bridge
LIU Feng,SUN Feng,MAO Hong,LI Ya-li,CHENG Hai-ming,CHEN Ji-wen. Quantity of released nickel ion from Ni-Cr alloy of compound galvano-ceramic bridge[J]. Chinese journal of stomatology, 2008, 43(3): 182-184
Authors:LIU Feng  SUN Feng  MAO Hong  LI Ya-li  CHENG Hai-ming  CHEN Ji-wen
Affiliation:Department of Special Dentistry, The First Outpatient Dental Clinic, Peking University School and Hospital of Stomatology, Beijing, China.
Abstract:OBJECTIVE: To evaluate the biological safety of compound galvano-ceramic bridge by measuring the consistency of released nickel ion of the galvano-form slices cohered with Ni-Cr alloy slice specimens which were immersed in artificial saliva. METHODS: Specimens were divided into five groups with four tests and one control. Test specimens were made into the structure like rectangle sandwich that one side of Ni-Cr alloy was cohered to the center surface of galvano golden base of 0.2 mm and another side was fused porcelain with the thickness of 0.3 mm (group A), 0.5 mm (group B), 1.0 mm (group C), and 0.3 mm (group D). And the Ni-Cr alloys were totally embedded in galvano golden base and firing porcelain. Naked Ni-Cr alloy was taken as control. Group D was immersed into acid artificial saliva (AS) with high fluoride, while others were in acid AS at 37 degrees C for 120 h. Then the consistency of released nickel ion in the solution was measured with inductively coupled plasma-atomic emission spectrometry (ICP-AES). RESULTS: Nickel ions detected in the artificial saliva for the groups A, B, C, and D in acid AS with or without high fluoride were all under 0.005 mg/L Significant differences were found between each test group and the control [(0.65 +/- 0.45) mg/L]. CONCLUSIONS: Galvano-ceramic bridge, Ni-Cr alloy bridge with fused porcelain and golden base, shows biological safety responsible for the consistency of released nickel ion.
Keywords:Metal ceramic alloys  Chronium alloys  Nickel
本文献已被 万方数据 等数据库收录!