THE EFFECT OF MISALIGNMENT ON THE FATIGUE STRENGTH OF WELDED CRUCIFORM JOINTS
Authors:R M Andrews
Affiliation:The Welding Institute, Abington Hall, Abington, Cambridge, CB1 6AL
Abstract:Abstract— The effect of axial misalignment on the fatigue strength of load-carrying transverse cruciform welded joints was investigated using experimental and fracture mechanics methods. Where failure occurred by cracking from the weld toe, misalignment significantly reduced the fatigue strength. The reduction could be predicted using a nominal stress concentration factor (SCF). Misalignment had less effect where failure was due to cracking through the weld metal; an expression was deduced for the SCF in this case. For fracture mechanics assessments, an expression for an effective stress intensity factor using the SCF and stress intensity factors for aligned welds was shown to agree with the finite element (FE) results. Predictions of the effect of misalignment using the FE results agreed with experimental data. Misaligned transverse load-carrying cruciform joints should be assessed for fatigue failure from the toe using the same SCF as for a butt weld with the same misalignment. For failure through the throat, an alternative expression for the SCF is recommended. Fracture mechanics assessments of misaligned joints should be carried out using an effective stress intensity factor derived from the SCF and stress intensity factors for aligned joints. These recommendations are now incorporated in British Standard PD 6493:1991.
Keywords:Welded cruciform joints  Joint misalignment  Stress intensity factors  Stress concentration factors  Finite element predictions
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号