首页 | 官方网站   微博 | 高级检索  
     

3cm以下肺腺癌与鳞癌的CT同层动态增强研究
引用本文:方丽,储成凤,杨明,张俭,郏爱明,陈龙桂,孟爱芳,张琳琴,金琴娣.3cm以下肺腺癌与鳞癌的CT同层动态增强研究[J].中国医学影像技术,2005,21(4):556-558.
作者姓名:方丽  储成凤  杨明  张俭  郏爱明  陈龙桂  孟爱芳  张琳琴  金琴娣
作者单位:东南大学附属中大医院放射科,江苏,南京,210009
摘    要:目的评价同层动态增强CT技术对3 cm以下肺腺癌和鳞癌的诊断价值.方法选择直径<3 cm的肺腺癌22例和肺鳞癌9例,平扫后静脉注入对比剂行同层动态增强CT扫描,测量其增强前后各时间段的CT值改变,计算最大CT强化值,绘制其时间-密度曲线.结果肺腺癌在增强后135 s和195 s时间段的CT强化值大于鳞癌,二者有明显统计学差异(P<0.05),余各时间段无明显差别(P>0.05).腺癌的时间-密度曲线为缓慢持续上升型,鳞癌为抛物线型.肺腺癌与鳞癌的增强效果皆始于35 s,但鳞癌峰值时间早于腺癌,二者峰值大小无统计学差异(P>0.05).结论同层CT动态增强扫描技术,在区分肺腺癌与鳞癌组织学类型方面有一定价值.

关 键 词:肺癌  硬币病变    体层摄影术  X线计算机  动态增强
文章编号:1003-3289(2005)04-0556-03
收稿时间:2004/11/17 0:00:00
修稿时间:2004年11月17

Single-location dynamic enhanced CT for lung adenocarcinoma and squamous carcinoma with diameter <3 cm
FANG Li,CHU Cheng-feng,YANG Ming,ZHANG Jian,JIA Ai-ming,CHEN Long-gui,MENG Ai-fang,ZHANG Lin-qin and JIN Qin-di.Single-location dynamic enhanced CT for lung adenocarcinoma and squamous carcinoma with diameter <3 cm[J].Chinese Journal of Medical Imaging Technology,2005,21(4):556-558.
Authors:FANG Li  CHU Cheng-feng  YANG Ming  ZHANG Jian  JIA Ai-ming  CHEN Long-gui  MENG Ai-fang  ZHANG Lin-qin and JIN Qin-di
Affiliation:Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China;Department of Radiology, the Affiliated Zhongda Hospital of Southeast University, Nanjing 210009, China
Abstract:Objective To evaluate the diagnostic value of single-location dynamic enhanced CT for lung adenocarcinoma and squamous carcinoma with diameter <3 cm. Methods Single-location dynamic enhanced CT in the patients with lung adenocarcinoma (22 cases) and lung squamous carcinoma (9 cases) were analyzed, and the time-intensity curves were created. Results The average degree of enhancement of lung adenocarcinoma were higher than that of squamous carcinoma in 135 s and 195 s ( P <0.05), and the other times were not significantly different (all P >0.05). The time-intensity curve of adenocarcinoma increased slowly, while squamous carcinoma's curve looked as a parabola and showed a slowly progress and then decreased slowly. Both enhanced start time of adenocarcinoma and squamous carcinoma began from 35 s, the peak time of squamous carcinoma was earlier than that of adenocarcinoma, the peak height of lung adenocarcinoma was higher than that of squamous carcinoma, but they were not significantly different ( P >0.05). Conclusion Single-location dynamic CT is helpful in differential diagnosis of lung adenocarcinoma and lung squamous carcinoma.
Keywords:Lung neoplasms  Coin lesion  pulmonary  Tomography  X-ray computed  Dynamic enhancement
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号