首页 | 官方网站   微博 | 高级检索  
     

NIKKISO DBB-27型血液透析机液路系统工作原理及故障报警分析
引用本文:吴军. NIKKISO DBB-27型血液透析机液路系统工作原理及故障报警分析[J]. 医疗卫生装备, 2010, 31(6): 100-102
作者姓名:吴军
作者单位:天津市第五中心医院设备科,天津,300450
摘    要:分析了NIKKISO DBB-27型血液透析机液路系统的系统结构及各组成部分的工作原理,并对相关故障报警的诊断和排除进行了详细论述,为及时、准确地诊断和排除血液透析机的故障提供了理论基础。

关 键 词:血液透析机  液路系统  复式泵

Work Mechanism of NIKKISO DBB-27 Hemodialysis Machine Liquid Path System and Fault Alarm Analysis
WU Jun. Work Mechanism of NIKKISO DBB-27 Hemodialysis Machine Liquid Path System and Fault Alarm Analysis[J]. Chinese Medical Equipment Journal, 2010, 31(6): 100-102
Authors:WU Jun
Affiliation:WU Jun(Equipment Department,the Fifth Central Hospital of Tianjin,Tianjin 300450,China)
Abstract:The system structure and work mechanism of the liquid path system of NIKKISO DBB-27 hemodialysis machine are analyzed.The diagnosis and exclusion of related faults are discussed in detail,which established the theoretical basis for timely,accurate diagnosis and removal of the failure.
Keywords:hemodialysis machine  liquid path system  duplex pump
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号