首页 | 官方网站   微博 | 高级检索  
     

绕板式高压容器的射线检测
引用本文:李学锋,肖迪红. 绕板式高压容器的射线检测[J]. 无损检测, 2008, 30(4): 232-234
作者姓名:李学锋  肖迪红
作者单位:1. 长沙明鉴检测技术有限公司,长沙,410015
2. 中南大学,长沙,410075
摘    要:对氨合成塔筒体泄漏情况进行了分析,提出了在制造过程中进行一次半厚度(30mm)射线检测,焊缝内表面进行100%磁粉检测。同时,在设备设计、制造和使用过程中应严格控制和管理。

关 键 词:射线检测  氨合成塔  泄漏  灵敏度
文章编号:1000-6656(2008)04-0232-03
修稿时间:2007-01-30

The NDT Analysis for the Leakage Reason of Ammonia Synthetic Tower Shell
LI Xue-Feng,XIAO Di-Hong. The NDT Analysis for the Leakage Reason of Ammonia Synthetic Tower Shell[J]. Nondestructive Testing, 2008, 30(4): 232-234
Authors:LI Xue-Feng  XIAO Di-Hong
Affiliation:LI Xue-Feng1; XIAO Di-Hong2(1.Changsha Mingjian Testing Ltd.; Changsha 410015; China; 2.Centra-South University; Changsha 410075; China);
Abstract:The leakage reason of ammonia synthetic tower shell was analyzed.It was proposed that both radiographic testing at half thickness and magnetic particle testing for weld surface were necessary during manufacture.On the same time,the design,manufacture and management for equipment should be strictly controlled and managed.
Keywords:Radiographic testing  Ammonia synthetic tower  Leakage  Radiographic sensitivity
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23