Novel Approach to Simulate Sleep Apnea Patients for Evaluating Positive Pressure Therapy Devices
Authors:Valentina Isetta  Josep M Montserrat  Raquel Santano  Alison J Wimms  Dinesh Ramanan  Holger Woehrle  Daniel Navajas  Ramon Farré
Affiliation:1. Unitat de Biofísica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Barcelona, Spain;2. CIBERES, Madrid, Spain;3. Sleep Laboratory, Pneumology Department, Hospital Clinic, Barcelona, Spain;4. Institut d''Investigacions Biomèdiques August Pi i Sunyer, IDIBAPS, Barcelona, Spain;5. ResMed Science Centre, Munich, Germany;6. Institute for Bioengineering of Catalonia, IBEC, Barcelona, Spain;Georgia State University, UNITED STATES
Abstract:Bench testing is a useful method to characterize the response of different automatic positive airway pressure (APAP) devices under well-controlled conditions. However, previous models did not consider the diversity of obstructive sleep apnea (OSA) patients’ characteristics and phenotypes. The objective of this proof-of-concept study was to design a new bench test for realistically simulating an OSA patient’s night, and to implement a one-night example of a typical female phenotype for comparing responses to several currently-available APAP devices. We developed a novel approach aimed at replicating a typical night of sleep which includes different disturbed breathing events, disease severities, sleep/wake phases, body postures and respiratory artefacts. The simulated female OSA patient example that we implemented included periods of wake, light sleep and deep sleep with positional changes and was connected to ten different APAP devices. Flow and pressure readings were recorded; each device was tested twice. The new approach for simulating female OSA patients effectively combined a wide variety of disturbed breathing patterns to mimic the response of a predefined patient type. There were marked differences in response between devices; only three were able to overcome flow limitation to normalize breathing, and only five devices were associated with a residual apnea-hypopnea index of <5/h. In conclusion, bench tests can be designed to simulate specific patient characteristics, and typical stages of sleep, body position, and wake. Each APAP device behaved differently when exposed to this controlled model of a female OSA patient, and should lead to further understanding of OSA treatment.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号