首页 | 官方网站   微博 | 高级检索  
     

基于动态矩阵控制的双有源桥DC-DC变换器电流应力优化策略
引用本文:杨向真,陈曦,杜燕,孔令浩.基于动态矩阵控制的双有源桥DC-DC变换器电流应力优化策略[J].电源学报,2020,18(6):105-114.
作者姓名:杨向真  陈曦  杜燕  孔令浩
作者单位:合肥工业大学,合肥工业大学,合肥工业大学,合肥工业大学
摘    要:为了提高拓展移相控制的双有源桥(DAB)DC-DC变换器的电压动态响应性能,降低系统的电流应力,利用使电流应力最小的优化相移角与输出电压之间的关系,提出了一种将电压动态矩阵控制(DMC) 算法与变换器电流应力优化方法相结合的控制算法,并从预测模型、滚动优化、反馈校正三个环节详细介绍了DAB的DMC电压预测控制的具体实现过程,最后,将所提出的控制方法与电压闭环PI控制的拓展移相电流应力优化算法进行仿真比较,仿真结果表明:该方法不仅减小了电流应力,而且在变换器启动阶段以及负载突变时,大大改善了变换器的电压动态响应性能。

关 键 词:双有源桥DC-DC变换器  拓展移相  动态矩阵控制  电流应力  动态性能
收稿时间:2020/7/30 0:00:00
修稿时间:2020/11/7 0:00:00

Optimal Current Stress Control Strategy for Dual Active Bridge DC-DC Converter Based on Dynamic Matrix Control
YANG Xiangzhen,CHEN Xi,DU Yan and KONG Linghao.Optimal Current Stress Control Strategy for Dual Active Bridge DC-DC Converter Based on Dynamic Matrix Control[J].Journal of power supply,2020,18(6):105-114.
Authors:YANG Xiangzhen  CHEN Xi  DU Yan and KONG Linghao
Affiliation:Hefei University of Technology,,Hefei University of Technology,
Abstract:In order to improve the voltage dynamic response performance and to reduce the current stress of the dual active bridge (DAB) DC-DC converter with extended phase shift control, a new control algorithm combining the dynamic matrix control (DMC) method for voltage response improvement and the current stress optimal method is proposed according to the relationship between the minimized shift phase ratio and the output voltage. The realization process of voltage predictive control based on DMC is introduced in detail in three aspects of model prediction, rolling optimization and error feedback compensation. Finally, the simulation results are compared between the proposed method and the traditional current stress optimal method based on the PI voltage control with extended-phase shift control. The simulation results show that this method can not only reduce the current stress, but also can greatly improve the voltage dynamic response performance of the DAB converter during the startup stage and the load mutation of the converter.
Keywords:dual active bridge DC-DC converters  extended-phase shift control  dynamic matrix method  current stress  dynamic response
点击此处可从《电源学报》浏览原始摘要信息
点击此处可从《电源学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23