摘    要:采用气相色谱外标法对推进剂药浆中的残留丙酮含量进行了定量测定。结果表明,该方法能够准确地测定推进剂药浆中的残留丙酮含量,方法的平均回收率为93.5%-97.0%,相对标准偏差RSD不大于4%,适合于推进剂药浆中残留丙酮含量的测定和监测。

关 键 词:气相色谱法  丙酮  推进剂  药浆

Determination of Residual Acetone Content in Propellant Slurry by Gas Chromatography
XU Shengliang,BAI Jie,HU Wei,HUANG Zhiping.Determination of Residual Acetone Content in Propellant Slurry by Gas Chromatography[J].Chemical Propellants & Polymeric Materials,2012(3):89-91.
Authors:XU Shengliang  BAI Jie  HU Wei  HUANG Zhiping
Affiliation:(The 42nd Institute of the Fourth Academy of CASC,Xiangyang 441003,China)
Abstract:The residual acetone content in propellant slurry was quantitatively determined by gas chromatography external standard method.The results show that this method can accurately determine residual acetone content in propellant slurry.The average recovery is 93.5%~97.0%,the relative standard deviation(RSD) is not more than 4%,so that the method is suitable for determining and monitoring the residual acetone content in propellant slurry.
Keywords:gas chromatography  acetone  propellant  slurry