首页 | 官方网站   微博 | 高级检索  
     

常顶换热器管束损坏原因分析及对策
引用本文:丁平安,常六喜. 常顶换热器管束损坏原因分析及对策[J]. 石油化工腐蚀与防护, 2000, 17(1): 17-18
作者姓名:丁平安  常六喜
作者单位:洛阳石化总厂炼油厂!河南省洛阳市 471012,洛阳石化总厂炼油厂!河南省洛阳市 471012
摘    要:洛阳炼油厂第14生产周期自1998年4月22日开工以来,3台常顶换热器先后出现内漏,对生产造成了较大的影响。文章从生产工艺和设备本身等角度对其损坏原因进行了分析并提出了相应的对策。

关 键 词:换热器  焊缝应力  腐蚀

Analysis of Tube Failure of Overhead Heat Exchangers of Atmospheric Distillation Unit and Countermeasures
Ding Ping''''an,Chang Liuxi. Analysis of Tube Failure of Overhead Heat Exchangers of Atmospheric Distillation Unit and Countermeasures[J]. Petrochemical Corrosion and Protection, 2000, 17(1): 17-18
Authors:Ding Ping''''an  Chang Liuxi
Abstract:Since the restart on April 22, 1998, Luoyang Refinery experienced leakages on 3 overhead heat exchangers in atmospheric distillation unit, which greatly affected the refinery operation. The causes of failure were analyzed in respect of the production process and equipment, and corresponding prevention measures were proposed.
Keywords:heat exchanger   weld seam stress   corrosionP
本文献已被 CNKI 维普 等数据库收录!