首页 | 官方网站   微博 | 高级检索  
     

辛安水厂复合预氧化方式选择试验研究
引用本文:鹿燕. 辛安水厂复合预氧化方式选择试验研究[J]. 供水技术, 2012, 6(3): 17-19
作者姓名:鹿燕
作者单位:胜利油田供水公司,山东东营,257055
摘    要:针对辛安水厂原水水质问题,通过静态试验考察了不同预氧化方式对混凝沉淀工艺净化效果的影响。结果表明,先投加0.2 mg/L的高锰酸钾,再投加1.0 mg/L的臭氧,可以明显降低混凝沉淀出水中的浊度、UV254及UV254/TOC,相应的去除率分别为85.3%,75.8%和55.9%;为有效控制出水AOC含量,实际运行中可以考虑采用先投加0.4 mg/L的高锰酸钾,再投加0.5 mg/L的臭氧的预氧化方式。

关 键 词:预氧化  高锰酸钾  臭氧

Experiment of the selection of combined preoxidation process for Xin' an Waterworks
Lu Yan. Experiment of the selection of combined preoxidation process for Xin' an Waterworks[J]. Water Technology, 2012, 6(3): 17-19
Authors:Lu Yan
Affiliation:Lu Yan ( Shengli Oil Field Water Supply Company, Dongying 257055, China)
Abstract:Aimed at the issues of raw water quality in Xin' an Waterworks, the static experiments were conducted to investigate the influence of various preoxidation process on purification effect of coagualtion and sedimentation. The results showed that the outflow turbidity, UV254 and UV254/TOC could be reduced significantly with a dosing 0.2 mg/L potassium permanganate first and then 1.0 mg/L ozone added, and the corresponding removal rates were 85.3% ,75.8% and 55.9% respectively. Preoxidation of dosing 0.4 mg/L potassium permanganate first and then adding 0.5 mg/L ozone could be adopted in practical operation in order to control the AOC in outflow.
Keywords:preoxidation  potassium permanganate  ozone
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23