首页 | 官方网站   微博 | 高级检索  
     

定桨距异步风电机组的低电压过渡能力改造
引用本文:丛雨,关勇,薛志凌,何芳. 定桨距异步风电机组的低电压过渡能力改造[J]. 内蒙古电力技术, 2012, 30(2): 77-81
作者姓名:丛雨  关勇  薛志凌  何芳
作者单位:内蒙古电力科学研究院,内蒙古呼和浩特,010020
摘    要:金风750 kW定桨距异步风力发电机组因无电力电子变频装置而不具有抵御电网电压跌落的能力.针对这一问题,对上述风机进行低电压过渡能力改造,通过在风机与箱式变压器之间设计安装彩钢板房,加装D-VAR RT电力电子设备,使风机在电网故障时保持发电机机端电压在额定水平上.改造后对系统进行了仿真建模试验,模拟电网电压跌落至额定值的20%极限状态下的风机与电网电压、电流变化情况,并进行了D-VAR RT设备并网运行后的静态试验数据采集分析.试验结果表明:改造后的风机具备低电压过渡功能,满足《风电场接入电力系统技术规定》要求的低电压过渡能力.

关 键 词:风力发电机组  低电压过渡能力  变频装置  噬能电阻  仿真试验  静态试验  电压跌落

Low Voltage Ride Through Revamp of Low Voltage Ride Through for Fixed Pitch Asynchronous Wind Turbine Generator System
Cong Yu , Guan Yong , Xue Zhiling , He Fang. Low Voltage Ride Through Revamp of Low Voltage Ride Through for Fixed Pitch Asynchronous Wind Turbine Generator System[J]. Inner Mongolia Electric Power, 2012, 30(2): 77-81
Authors:Cong Yu    Guan Yong    Xue Zhiling    He Fang
Affiliation:(Inner Mongolia Electric Power Science & Research Institute,Inner Mongolia Hohhot 010020)
Abstract:Jinfeng 750 kW fixed pitch asynchronous wind turbine power generator does not have ability to resist the power grid voltage drop owing to no power frequency electronic inverter devices.To solve this problem,revamp of low voltage ride through has been undertaken to wind turbine mentioned above,through design and installation of color steel plate between the fan and box-type transformer and installation of D-VAR RT power electronic devices so that can maintain generator terminal voltage at rated level when wind turbine power generator is in power grid failure.After revamp,we have made system simulation modeling experiments,to simulate situation of power grid voltage and current changes when grid voltage drops to 20% under ultimate state,and make static data acquisition analysis after parallel operation of D-VAR RT equipment with power grid.Testing results show that after revamp,wind turbine has low voltage ride through function to satisfy requirements of low voltage ride through stipulated in Technical Requirements of Wind Farms Parallel into Power Systems.
Keywords:wind turbine generator system  low voltage ride through  frequency devices  macrophages resistance  simulation test  static test  voltage drop
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号