首页 | 官方网站   微博 | 高级检索  
     

LI-RADS超声分类诊断肝脏占位性病变准确性分析
引用本文:罗利红,胡洁,周启. LI-RADS超声分类诊断肝脏占位性病变准确性分析[J]. 实用肝脏病杂志, 2020, 23(5): 731-734. DOI: 10.3969/j.issn.1672-5069.2020.05.032
作者姓名:罗利红  胡洁  周启
作者单位:423000 湖南省郴州市第一人民医院超声科(罗利红);海南省人民医院超声科(胡洁);湖南中医药大学第一附属医院麻醉科(周启)
基金项目:湖南省卫生与健康委员会科研计划项目【湘卫函(2018)533号-C20190072】
摘    要:目的 探讨应用LI-RADS超声分类方法诊断肝脏占位性病变的准确性。方法 2018年1月~2019年9月我院经病理学检查诊断为肝脏占位性病变患者60例,均接受超声造影检查。按照LI-RADS分类方法,分别以LR-3(方法1)和LR-4a(方法2)作为为截断点,分析两种方法鉴别良恶性病变的效能。结果 在60例肝占位性病变患者中,综合诊断肝囊肿4例,肝血管瘤16例,肝脓肿8例,肝局灶性脂肪变9例,肝局灶性结节性增生9例,肝细胞癌8例,肝转移瘤6例;以病理学检查诊断为金标准,方法1诊断恶性病变22例,良性病变38例。方法 2诊断恶性病变14例,良性病变46例;方法1诊断的灵敏度、特异度和正确率分别为85.7%、78.2%和80.0%,而方法2则分别为78.6%、93.5%(P<0.05)和100.0%(P<0.05)。结论 采用LI-RADS 方法2分辨肝脏占位性病变的性质具有很高的准确性,其临床应用价值值得进一步研究。

关 键 词:肝脏占位性病变  超声造影  肝脏影像学报告和数据系统  诊断         

Diagnostic accuracy ofcontrast enhanced ultrasound by LI-RADS in patients with space-occupying liver lesions
Luo Lihong,Hu Jie,Zhou Qi.. Diagnostic accuracy ofcontrast enhanced ultrasound by LI-RADS in patients with space-occupying liver lesions[J]. Journal of Clinical Hepatology, 2020, 23(5): 731-734. DOI: 10.3969/j.issn.1672-5069.2020.05.032
Authors:Luo Lihong  Hu Jie  Zhou Qi.
Affiliation:Department of Ultrasound, First People's Hospital, Chenzhou 423000, Hunan Province, China
Abstract:Objective The aim of this study was to explore the diagnostic accuracy of contrast enhanced ultrasound (CEUS) by liver imaging report and data system (LI-RADS) in patients with space-occupying liver lesions. Methods 60 patients were clinically confirmed with space-occupying liver lesions in our hospital between January 2018 and September 2019, and all underwent CEUS. The imaging was classified according to LI-RADS and the diagnostic accuracy was evaluated when LR-3 or LR-4a was assumed as cut-off value. Results Out of the 60 patients, the histopathological examination showed that there were 4 cases with hepatic cysts, 16 cases with hepatic hemangioma, 8 cases with liver abscess, 9 cases with focal hepatic steatosis, 9 cases with focal hepatic hyperplasia, 8 cases with hepatocellular carcinoma and 6 cases with liver metastases; when the pathological diagnosis was set as the gold standard, the LR-3 diagnosed malignant foci in 22, and benign lesions in 38 patients, and the LR-4a diagnosed malignant in 14 patients and benign foci in 46 patients; the sensitivity, specificity and accuracy by the the former were 85.7%, 78.2% and 80.0%, and by the latter were 78.6%, 93.5%(P<0.05)and 100.0%(P<0.05). Conclusion The LR-4a of LI-RADS from CEUS could be applied to differentiate liver lesions, which have a relatively good efficacy and warrants further investigation.
Keywords:Space-occupying liver lesion   Contrast-enhanced ultrasound   Liver imaging reporting and data system   Diagnosis  
本文献已被 CNKI 等数据库收录!
点击此处可从《实用肝脏病杂志》浏览原始摘要信息
点击此处可从《实用肝脏病杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号