首页 | 官方网站   微博 | 高级检索  
     

电感耦合等离子体光谱法/质谱法测定自然铜不同炮制品中砷、铅、铜、镉、汞的含量
引用本文:李伟东,张志杰,陈逸君,吴育,史业东,张孟群.电感耦合等离子体光谱法/质谱法测定自然铜不同炮制品中砷、铅、铜、镉、汞的含量[J].中国实验方剂学杂志,2012,18(24):181-186.
作者姓名:李伟东  张志杰  陈逸君  吴育  史业东  张孟群
作者单位:1. 南京中医药大学,南京,210046
2. 中国中医科学院中药研究所,北京,100070
3. 南京大学现代分析中心,南京,210009
基金项目:国家药典委员会国家药品标准提高研究课题(361388)
摘    要:目的:建立电感耦合等离子体光谱法/质谱法(ICP-AES/MS)测定自然铜不同炮制品中砷(As)、铅(Pb)、铜(Cu)、镉(Cd)和汞(Hg)含量检测方法,为制定As,Pb,Cd,Hg等有害元素的限量标准提供依据。方法:ICP-AES/MS检测经微波消解法的供试品,通过校正曲线计算含量。结果:5种元素标准曲线线性关系良好,r=0.999 2~0.999 8,回收率符合痕量分析要求。结论:方法灵敏度高,检测限低,分析速度快,分析精密度高。

关 键 词:电感耦合等离子体光谱法/质谱法  有害元素  自然铜  煅自然铜
收稿时间:2012/10/15 0:00:00

Determination of Elements of Cu,As,Pb,Cd and Hg in Different Pocessed Products of Pyrite
LI Wei-dong,ZHANG Zhi-jie,CHEN Yi-jun,WU Yu,SHI Ye-dong and ZHANG Meng-qun.Determination of Elements of Cu,As,Pb,Cd and Hg in Different Pocessed Products of Pyrite[J].China Journal of Experimental Traditional Medical Formulae,2012,18(24):181-186.
Authors:LI Wei-dong  ZHANG Zhi-jie  CHEN Yi-jun  WU Yu  SHI Ye-dong and ZHANG Meng-qun
Affiliation:Jiangsu Key Laboratory of Chinese Medicine Processing, Nanjing University of Chinese Medicine, Nanjing 210046, China;Institute of Chinese Materia Medica China Academy of Chinese Medical Sciences,Beijing 100070,China;Modern Analysis Center of Nanjing University, Nanjing 210009, China;Jiangsu Key Laboratory of Chinese Medicine Processing, Nanjing University of Chinese Medicine, Nanjing 210046, China;Jiangsu Key Laboratory of Chinese Medicine Processing, Nanjing University of Chinese Medicine, Nanjing 210046, China;Modern Analysis Center of Nanjing University, Nanjing 210009, China
Abstract:Objective:To establish a method for the determination of 5 elements (As, Pb,Cu,Cd and Hg) in different pocessed products of pyrite by inductively coupled plasma atomicemission spectrometry/mass spectrometry(ICP-AES/MS), in order to provide a basis for thelimit standards of As, Pb,Cu, Cd and Hg and other harmful elements. Method: Five elements of the digested samples were determined by ICP-AES/MS simultaneously, and the contents were calculated by calibration curves. Result: Good linearity of calibration curves was obtained for ICP-AES/MS assay, the accuracy and the recovery met the requirement of trace analysis. Conclusion: The method is highly sensitive,rapid,accuracy and offered with low LOD.
Keywords:ICP-AES/MS  harmful elements  pyrite  calcining and quenching pyrite