首页 | 官方网站   微博 | 高级检索  
     

乌江某水电站压力钢管的安全性评价
引用本文:李荣锋,陈颜堂,陈晓.乌江某水电站压力钢管的安全性评价[J].钢铁研究,2006,34(6):54-56.
作者姓名:李荣锋  陈颜堂  陈晓
作者单位:武汉钢铁集团公司,技术中心,湖北,武汉,430080
摘    要:基于WDL610钢的NDT评价和断裂评定表明,乌江某水电站压力钢管在焊态情况有足够的断裂抗力,是安全的.同时鉴于工程实际情况可以免除消除残余应力处理.

关 键 词:压力钢管  安全评定  消除残余应力
文章编号:1001-1447(2006)06-0054-03
收稿时间:2006-06-26
修稿时间:2006-06-26

Safety assessment on penstock used in a hydropower station of Wujiang River
LI Rong-feng,CHEN Yan-tang,CHEN Xiao.Safety assessment on penstock used in a hydropower station of Wujiang River[J].Research on Iron and Steel,2006,34(6):54-56.
Authors:LI Rong-feng  CHEN Yan-tang  CHEN Xiao
Affiliation:Technology Center, Wuhan Iron and Steel Corp. , Wuhan 430080 China
Abstract:Based on the NDT test results and fracture analysis of WDL610D steel, it is concluded that the penstock in a hydropower station of Wugiang River with enough fracture resistance is safe and relieving welding residual stress is un necessary.
Keywords:penstock  safety assessment  relief residual stress
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号