首页 | 官方网站   微博 | 高级检索  
     

AP1000安全壳流动循环与热分层一维模型分析
引用本文:玉宇,张鹤,单祖华,胡迎秋,王升飞,牛风雷,刘鑫,刚直.AP1000安全壳流动循环与热分层一维模型分析[J].原子能科学技术,2014,48(10):1803-1806.
作者姓名:玉宇  张鹤  单祖华  胡迎秋  王升飞  牛风雷  刘鑫  刚直
作者单位:1.华北电力大学 核科学与工程学院 非能动核能安全技术北京市重点实验室,北京102206;2.上海核工程研究设计院,上海200233;3.国家核电技术研发中心,北京100010
基金项目:国家自然科学基金资助项目(51206042);中央高校基本科研业务经费资助项目
摘    要:非能动安全壳冷却系统是先进大型压水堆AP1000核电厂的重要安全系统之一,该系统利用安全壳内及安全壳外空气流道中的自然循环过程将安全壳内的热量带至环境中,大空间内的循环与热分层现象对安全壳内的传热及流动特性具有重要影响。本文基于热分层理论,针对钢制安全壳内、外的自然循环过程,建立一维计算模型,在提高计算效率的基础上,得到安全壳内的温度分布,并与三维模型的计算结果进行了对比,验证了模型的合理性;同时得到了安全壳内压力及组分的分布。

关 键 词:非能动安全壳    热分层    一维模型

One-dimensional Model Analysis of Flow Circulation and Thermal Stratification in AP 1000 Containment
YU Yu,ZHANG He,SHAN Zu-hua,HU Ying-qiu,WANG Sheng-fei,NIU Feng-lei,LIU Xin,GANG Zhi.One-dimensional Model Analysis of Flow Circulation and Thermal Stratification in AP 1000 Containment[J].Atomic Energy Science and Technology,2014,48(10):1803-1806.
Authors:YU Yu  ZHANG He  SHAN Zu-hua  HU Ying-qiu  WANG Sheng-fei  NIU Feng-lei  LIU Xin  GANG Zhi
Affiliation:1.Beijing Key Laboratory of Passive Nuclear Safety Technology, School of Nuclear Science and Engineering, North China Electric Power University, Beijing 102206, China;2.Shanghai Nuclear Engineering Research & Design Institute, Shanghai 200233, China;3.State Nuclear Power Technology R&D Center, Beijing 100010, China
Abstract:Passive containment cooling system is one of the important safety systems in AP1000. The heat produced in the containment can be transferred to the atmosphere based on natural circulation both in the containment and in the air flow channel outside the containment. The flow circulation and thermal stratification in the large volume of the containment have essential effect on the flow and heat transfer. In this paper, one-dimensional thermal-hydraulic model was established based on stratification theory for the natural circulations in and outside the steel containment. The calculation efficiency was improved and the temperature distribution was obtained. By comparing with the result of the three-dimensional model, the rationality of the one-dimensional model was verified. The pressure and constituent distributions in the containment were also calculated.
Keywords:passive containment  thermal stratification  one-dimensional model
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23