摘    要:配电网信息物理系统(CPSDN)中信息系统和物理系统深度耦合,使得信息和物理故障可以相互耦合对配电网的运行造成影响.文中提出一种配电网信息物理故障的耦合度计算方法,从故障危害的角度评估信息与物理系统间的耦合程度.首先,在分析信息物理协同攻击(CCPA)对CPSDN影响的基础上,综合考虑攻击造成的故障危害及节点的防护水平...

关 键 词:配电网信息物理系统  耦合度  信息物理协同攻击  定量评估
收稿时间:2020-04-30
修稿时间:2020-09-28

Calculation Method for Coupling Degree of Cyber-Physical Fault in Distribution Networks
QIN Han,LIU Dong. Calculation Method for Coupling Degree of Cyber-Physical Fault in Distribution Networks[J]. Automation of Electric Power Systems, 2021, 45(3): 76-82. DOI: 10.7500/AEPS20200430025
Authors:QIN Han  LIU Dong
Affiliation:Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education (Shanghai Jiao Tong University), Shanghai 200240, China
Abstract:Since the cyber system and the physical system in the cyber-physical system for distribution network (CPSDN) are deeply coupled, the cyber and physical failure can couple with each other to affect the operation of the distribution network. This paper proposes a coupling degree calculation method, which evaluates the coupling degree between the cyber and physical system from the perspective of fault hazard. Firstly, based on analyzing the impact of coordinated cyber-physical attack (CCPA) on CPSDN, considering the fault hazard caused by attacks and the protection level of nodes, a probabilistic expression of faults is given. Then, the correlation degree of node failures between heterogeneous systems is calculated through the coupling degree between nodes (CDBN), and the coupling degree between node and system (CDBNS) and coupling degree between systems (CDBS) are calculated based on CDBN. Finally, a distribution network with three feeders is used as an example to verify the rationality and effectiveness of the proposed method.
Keywords:cyber-physical system for distribution network (CPSDN)  coupling degree  coordinated cyber-physical attack (CCPA)  quantitative assessment
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《电力系统自动化》浏览原始摘要信息
点击此处可从《电力系统自动化》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号