首页 | 官方网站   微博 | 高级检索  
     

天津北疆发电厂12000m^2海水冷却塔设计
引用本文:曾建柱.天津北疆发电厂12000m^2海水冷却塔设计[J].电力建设,2009,30(2):58-60.
作者姓名:曾建柱
作者单位:北京国电华北电力工程有限公司,北京市,100011
摘    要:天津北疆发电厂海水冷却塔淋水面积为12000m^2,是国内面积最大的逆流式自然通风海水冷却塔之一。该海水冷却塔采用S型波改性PVC淋水填料、XPH蜗壳旋流型喷溅装置、BO160-45型PVC收水器,配水型式为虹吸式竖井、管式配水。模拟试验表明,海水冷却塔设计合理、符合规范。

关 键 词:海水冷却塔  逆流式自然通风冷却塔  虹吸式竖井配水  防冻  防腐蚀

Design of 12000 m~2 Seawater Cooling Tower of Tianjin Beijiang Power Plant
ZENG Jian-zhu.Design of 12000 m~2 Seawater Cooling Tower of Tianjin Beijiang Power Plant[J].Electric Power Construction,2009,30(2):58-60.
Authors:ZENG Jian-zhu
Affiliation:NorthChinaPowerEngineeringCo.;Beijing 100011;China
Abstract:The counterflow natural-draft seawater cooling tower in Tianjin Beijiang Power Plant has the largest area in the nation.and its spraying area of the tower is 12 000 m2.S-shaped PVC filling,XPH helicoidal spinning spraying device,BO160-45 PVC water collector,and suction type shaft and piping distribution are used in water supply are used in the tower.Simulation tests show that the tower is well-designed and in line with criterions.
Keywords:seawater cooling tower  counterflow natural-draft cooling tower  suction type shaft water distribution  antifreezing  anticorrosion  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《电力建设》浏览原始摘要信息
点击此处可从《电力建设》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏