首页 | 官方网站   微博 | 高级检索  
     

热泵闪蒸汽提脱氨技术的工业应用
引用本文:张三华,刘文彬,倪黎,涂娟.热泵闪蒸汽提脱氨技术的工业应用[J].工业催化,1992,28(9):78-80.
作者姓名:张三华  刘文彬  倪黎  涂娟
作者单位:中国石化催化剂有限公司长岭分公司,湖南 岳阳 414012
摘    要:采用热泵闪蒸汽提脱氨技术建成一套催化剂废水氨氮处理装置,运行结果表明,在汽提温度(90~100) ℃和进料量(70~120) m3·h-1条件下,可以将废水氨氮由大于2 000 mg·L-1脱至小于8 mg·L-1,具有脱氨效率高、运行成本低和综合效益好的特点,在国内高氨氮废水处理技术中处于先进水平。


Commercial application of ammonia removal technology by heat-pump flash steam stripping process
Zhang Sanhua,Liu Wenbin,Ni Li,Tu Juan.Commercial application of ammonia removal technology by heat-pump flash steam stripping process[J].Industrial Catalysis,1992,28(9):78-80.
Authors:Zhang Sanhua  Liu Wenbin  Ni Li  Tu Juan
Affiliation:Changling Division of Sinopec Catalyst Company,Yueyang 414012,Hunan,China
Abstract:A set of catalyst wastewater treatment unit for ammonia removal by heat-pump flash steam stripping process was built.The results of running showed that when stripping temperature was (90-100) ℃ and inlet amount was (70-120) m3·h-1 ,ammonia of wastewater could be reduced to less than 8 mg·L-1 from more than 2 000 mg·L-1.It's an advanced technology of high ammonia wastewater treatment in China and has the characteristics of high ammonia removal efficiency,low operating cost and better comprehensive benefits.
Keywords:
点击此处可从《工业催化》浏览原始摘要信息