首页 | 官方网站   微博 | 高级检索  
     


Design of the thermal neutron beam for neutron radiography at the Syrian MNSR
Authors:Ismail Shaaban
Affiliation:Nuclear Engineering Dept., Atomic Energy Commission, P.O. Box 6091, Damascus, Syria
Abstract:Neutron beam design was studied at the Syrian reactor (MNSR, 30 kW) with a view to generating thermal neutron beam in the vertical irradiation sites for neutron radiography. The design of the neutron collimator was performed using MCNP4C and the ENDF/B-V cross-section library. Thermal, epithermal and fast neutron energy ranges were selected as <0.4 eV, 0.4 eV–10 keV, >10 keV, respectively. To produce a good neutron beam quality, bismuth was used as photon filter. In this design, the L/D ratio of this facility had the value of 125. The thermal neutron flux at the beam exit was about 2.548 × 105 n/cm2 s. If such neutron beam were built into the Syrian MNSR many scientific applications would be available using the neutron radiography.
Keywords:Syrian MNSR  Neutron radiography  Thermal neutron  Photon filter  MCNP code
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23