首页 | 官方网站   微博 | 高级检索  
     

64排螺旋CT冠脉成像效果与影响因素研究
引用本文:李伟,陈雄钊,兰勇,胡茂清,罗学毛,龙晚生. 64排螺旋CT冠脉成像效果与影响因素研究[J]. 国际生物医学工程杂志, 2009, 32(5). DOI: 10.3760/cma.j.issn.1673-4181.2009.05.003
作者姓名:李伟  陈雄钊  兰勇  胡茂清  罗学毛  龙晚生
作者单位:江门市中心医院放射科,529030;江门市中心医院放射科,529030;江门市中心医院放射科,529030;江门市中心医院放射科,529030;江门市中心医院放射科,529030;江门市中心医院放射科,529030
摘    要:目的 探讨64排螺旋CT冠脉成像中影响图像质量的各种因素及其影响程度以及评估冠脉狭窄的效果.方法 通过838例临床疑似冠心病患者的6_4排螺旋CT冠脉成像,并以其中218例在1周内进行的常规冠状动脉造影为标准,分析64排螺旋CT冠脉成像在评估冠脉狭窄的灵敏度、准确率、阳性预测值和阴性预测值.结果 心率、心率变化幅度、延迟时间设定、β受体阻滞剂、呼吸频率、屏气合作与否、造影剂注射总量与速度、图像重建时相、冠状动脉钙化、扫描参数、患者年龄性别、机器软硬件性能等是影响64排螺旋CT成像质量的因素.64排螺旋CT冠脉成像评估冠脉狭窄的准确率为95.9%,阳性与阴性预测值分别为92.3%、90.0%.结论 得到了影响64排螺旋CT冠脉成像的各种因素,分析了减少和消除这些因素影响的方法.在评估冠脉狭窄方面,64排螺旋CT冠脉成像基本能满足临床要求.Abstract:Objective To study the various factors that influence image quality of 64-slice spiral CT coronary artery imaging, their impact extent and the assessment effect of coronary artery stonnsis. Methods Through examination of 838 clinical coronary heart disease suspect patients, by 64-slice spiral CT coronary artery imaging, in which, 218 patients were also examined by conventional coronary angiagraphy in a week, we took the conventional coronary angiography as the standard, analyzed the 64-slice spiral CT coronary artery imaging in the assessment of coronary artery stenosis by sensitivity, accuracy, positive predictive value and negative predictive value. Results The factors which affect the image quality of 64-slice spiral CT coronary artery imaging include heart rate, heart rate change range, delay time setting, β-blocker, respiratory rate, breath-holding or not, total amount of contrast medium and the speed of injection, image reconstruction phase, coronary artery calcification, the scan parameters, age and sex of patients, machine

关 键 词:64排螺旋CT  冠脉成像  质量控制  冠脉造影术  冠脉狭窄

Study on effect and influence factors of the coronary artery imaging by 64-slice spiral CT
Abstract:Objective To study the various factors that influence image quality of 64-slice spiral CT coronary artery imaging, their impact extent and the assessment effect of coronary artery stonnsis. Methods Through examination of 838 clinical coronary heart disease suspect patients, by 64-slice spiral CT coronary artery imaging, in which, 218 patients were also examined by conventional coronary angiagraphy in a week, we took the conventional coronary angiography as the standard, analyzed the 64-slice spiral CT coronary artery imaging in the assessment of coronary artery stenosis by sensitivity, accuracy, positive predictive value and negative predictive value. Results The factors which affect the image quality of 64-slice spiral CT coronary artery imaging include heart rate, heart rate change range, delay time setting, β-blocker, respiratory rate, breath-holding or not, total amount of contrast medium and the speed of injection, image reconstruction phase, coronary artery calcification, the scan parameters, age and sex of patients, machine hardware and software performance and so on. The accuracy of the 64-slice spiral CT coronary artery imaging assessment of coronary artery stenasis was 95.9 % while the predictive values were 92.3%, 90.0% for positive and negative, respectively. Conclusion The influential factors are introduced as well as the methods that wig reduce or eliminate these factors. In the application of assessing coronary artery stonnsis, 64-slice spiral CT coronary artery imaging can basically meet the clinical requirements.
Keywords:64 slice spiral CT  Coronary artery imaging  Quality control  Coronary angiography  Coronary artery stenosis
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号