一起主换热器氧通道堵塞的原因分析及处理
引用本文:夏天俊 袁建中. 一起主换热器氧通道堵塞的原因分析及处理[J]. 深冷技术, 2007, 0(B12): 52-53
作者姓名:夏天俊 袁建中
作者单位:安钢集团信阳钢铁有限公司炼钢厂制氧车间,河南省信阳市明港镇西环路1号464194
摘    要:10000m^3/h空分设备因雷击、电网故障连续两次停车后,氧气出塔压力下降,原因为雨水进入主换热器冷端,使氧通道堵塞。通过大加温消除了故障。

关 键 词:大型空分设备 主换热器 氧通道 堵塞
收稿时间:2007-04-10

Cause analysis and treatment of a blockage in the oxygen channel of a main heat exchanger
Xia Tian-jun, Yuan Jian-zhong. Cause analysis and treatment of a blockage in the oxygen channel of a main heat exchanger[J]. Cryogenic Technology, 2007, 0(B12): 52-53
Authors:Xia Tian-jun   Yuan Jian-zhong
Abstract:The outlet oxygen pressure from the column of a 10000m^3/h air separation unit was found lower than usual level, after two shutdowns due to lightning strike and electric network failure. The pressure drop is attributed to the blockage in oxygen channel caused by the intruding rainwater at the cold end of main heat exchanger. The malfunction was successfully cleared off through intense wanning up.
Keywords:Large scale air separation unit   Main heat exchanger   Oxygen channel   Blockage