摘    要:介绍了40000m3/h空分设备钎焊板翅式换热器运行中发生的内漏和外漏故障,分析了原因及处理措施。

关 键 词:大型空分设备  板翅式换热器  泄漏
文章编号:1009-9425(2006)01-0051-03
收稿时间:2005-06-14
修稿时间:2005-06-14

Analysis and treatment of main heat exchanger leakage in a 40000 m3/h air separation unit
Li Wen-long. Analysis and treatment of main heat exchanger leakage in a 40000 m3/h air separation unit[J]. Cryogenic Technology, 2006, 0(1): 51-53
Authors:Li Wen-long
Affiliation:Henan Longyu Coal Chemical Co. , Ltd. , Yongcheng 476600, Henan, P.R. China
Abstract:The internal and external leakages of the sintered platefin heat exchanger in a 40000m~3/h air separation unit have been introduced.Based on cause analysis,corresponding treatment has also been proposed for the fault.