小型高性能质子转移反应飞行时间质谱仪的研制及其在呼吸气成分分析中的应用
引用本文:赵忠俊,贺飞耀,郭星,李雯雯,代渐雄,付玉,李宏,邓辅龙,蒲娟,杨燕婷,王旭,段忆翔.小型高性能质子转移反应飞行时间质谱仪的研制及其在呼吸气成分分析中的应用[J].质谱学报,2021,42(3):285-293.
作者姓名:赵忠俊  贺飞耀  郭星  李雯雯  代渐雄  付玉  李宏  邓辅龙  蒲娟  杨燕婷  王旭  段忆翔
作者单位:四川大学化学工程学院,四川 成都610064;四川大学生命科学学院,四川 成都610064;西北大学化学与材料科学学院,陕西 西安710127;4.四川大学华西公共卫生学院,四川 成都610064;四川大学机械工程学院,四川 成都610064;四川大学化学学院,四川 成都610064;成都艾立本科技有限公司,四川 成都611930
摘    要:研制可快速、在线分析挥发性有机物(volatile organic compounds,VOCs)的质谱仪器是现代气态有机质谱的重要发展方向.本研究自行研制了小型高性能质子转移反应飞行时间质谱仪(proton transfer reaction time of flight mass spectrometry,PTR-...

关 键 词:飞行时间质谱仪  质子转移反应  挥发性有机物  在线分析

Development of Small Sized High Performance Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-TOF MS) and Its Application in VOCs Analysis in Exhaled Gas
ZHAO Zhong-jun,HE Fei-yao,GUO Xing,LI Wen-wen,DAI Jian-xiong,FU yu,LI Hong,DENG Fu-long,PU Juan,YANG Yan-ting,WANG Xu,DUAN Yi-xiang.Development of Small Sized High Performance Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-TOF MS) and Its Application in VOCs Analysis in Exhaled Gas[J].Journal of Chinese Mass Spectrometry Society,2021,42(3):285-293.
Authors:ZHAO Zhong-jun  HE Fei-yao  GUO Xing  LI Wen-wen  DAI Jian-xiong  FU yu  LI Hong  DENG Fu-long  PU Juan  YANG Yan-ting  WANG Xu  DUAN Yi-xiang
Affiliation:School of Chemical Engineering, Sichuan University, Chengdu 610064, China;College of Life Science, Sichuan University, Chengdu 610064, China;College of Chemistry and Materials Science, Northwest University, Xi'an 710127, China;West China School of Public Health, Sichuan University, Chengdu 610064, China;School of Mechanical Engineering, Sichuan University, Chengdu 610064, China;College of Chemistry, Sichuan University, Chengdu 610064, China;ALIBEN Science&Technology, Chengdu 611930, China
Abstract:Nowadays, trend of novel mass spectrometer development concentrates on fast, on-line analysis of samples with minor or without pretreatment. An important branch of modern mass spectrometer development is to build a fast and on-line instrument for volatile organic compounds (VOCs) analysis. In this study, a high-performance small size proton transfer reaction-time of flight mass spectrometer (PTR-TOF MS) was developed. The structure of the instrument was described in detail as well as the performance test and applications in exhaled gas analysis. The ion source of the described PTR-TOF MS utilized a simple structure hollow cathode discharge to produce hydronium ion. A linear drift tube was designed as the ion molecule reactor. The mass spectrum of reagent ion showed that the base peak of reagent ion was H3O+ (m/z 19). Intensity of (H2O)nH3O+ (n=1, m/z 37) was 5% of H3O+ (m/z 19). The main pollution ion NO+ (m/z 30) was 0.5% of H3O+ (m/z 19) which indicated that the purity of the ion source was good for proton transfer reaction. A direct current was arranged evenly across the whole reaction tube to maintain a consistent reaction E/N. The interface between ion source and TOF MS was a RF-only quadruple. The frequency and voltage of the RF-only quadruple were adjusted for the best transferring of VOCs ions. A set of focus lenses and collimation lenses was followed for ion beam refining before entering mass analyzer. The mass analyzer used in this instrument was a small sized time of flight mass spectrometer. The total length of the mass analyzer was 360 mm which ensured the small size of the instrument. The time of flight mass spectrometer used orthogonal acceleration, twin pulse, reflect second-order focusing was used to maximum the resolution. Experiment result showed that the full width half maximum m/z 115 is better than 2 500. The detect limit for acetone, benzene and toluene is from 6×10-12 mol/mol to 9.6×10-11 mol/mol. The instrument also shows good linearity between concentration 1×10-8 mol/mol and 1×10-6 mol/mol. The instrument was successfully applied to component analysis of human exhaled gas. Further works will be concentrated on the quantitative analysis of components of real samples. The developed high-performance small size PTR-TOF MS has potential in applications in environment, biology, petrochemical industry etc.
Keywords:time of flight mass spectrometry  proton transfer reaction  volatile organic compounds detection  on-line analysis  