首页 | 官方网站   微博 | 高级检索  
     


Nondestructive Evaluation of a Haulage Rope in a Monocable Continuously Moving Passenger Ropeway
Authors:Debasish Basak  Srimanta Pal  Dipak Chandra Patranabis
Affiliation:(1) Electrical Laboratory, Central Institute of Mining and Fuel Research, Barwa Road, Dhanbad, 826001, India;(2) Electronics & Communication Sciences Unit, Indian Statistical Institute, 203 B.T. Road, Kolkata, 700108, India;(3) Department of Instrumentation and Electronics Engineering, Jadavpur University, Salt Lake Campus, Kolkata, 700098, India;(4) Heritage Institute of Technology, Kolkata, 700107, India
Abstract:The theoretical basis of detecting wire rope anomalies using permanent magnetic field has been fully established. The local faults (LF) such as broken wires and loss of metal area (LMA) signals are provided by nondestructive evaluation instruments. These signals represent the electronic equivalent of the mechanical anomalies present in the wire rope. The saturating magnetic field of the instrument makes the anomalies visible to the magnetic sensors placed around the rope. The condition of a haulage rope (construction 6X19) in a monocable continuously moving passenger ropeway has been studied using this nondestructive method, and the results are presented in this paper.
Keywords:Haulage  Nondestructive evaluation  Flaws
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23