摘    要:用电负荷的大范围波动导致传统电能表计量误差很大。本文设计了一种应用于0.05级三相标准电能表的数据采集系统,该系统由高精度数据采集电路和FPGA搭建而成。高精度数据采集电路由信号调理电路和24位A/D转换器组成,采样率高达52.73kHz,满足了系统采集精度的要求。采集系统的精度通过采集直流电压信号进行测试,误差小于0.02%。

关 键 词:A/D采集;FPGA;三相标准电能表;信号调理
收稿时间:2015-01-06
修稿时间:2015-04-29

High Precision Data Acquisition System for Three-Phase Standard Energy Meter
SHEN Li,BI Wei,GAN Yi-yi,LU Jun,PENG Yun and WANG Xianwei. High Precision Data Acquisition System for Three-Phase Standard Energy Meter[J]. Electrical Measurement & Instrumentation, 2015, 52(18)
Authors:SHEN Li  BI Wei  GAN Yi-yi  LU Jun  PENG Yun  WANG Xianwei
Affiliation:State Grid Hubei Electric Power Research Institute,Wuhan,State Grid Hubei Electric Power Research Institute,Wuhan,State Grid Hubei Electric Power Research Institute,Wuhan,Radium-Ray Shanghai Precision Instrument Co,Ltd,Shanghai,Radium-Ray Shanghai Precision Instrument Co,Ltd,Shanghai,School of Instrumentation Science and Opto-electronics Engineering,
Abstract:Wide range fluctuation load leads the traditional electric energy meter have large measurement uncertainty. This paper designed a high precision data acquisition system for three-phase standard energy meter. The system is consisted by FPGA and high precision data acquisition circuit. The high precision data acquisition circuit is combination by signal modulate circuit and 24 bit A/D converter in which the sampling rate is up to 52.73 kHz, these meet the requirement of acquisition precision. The system is test by acquire DC voltage, and the error is less than 0.02%.
Keywords:AD sampling   FPGA   three-phase standard energy meter   signal modulate
本文献已被 万方数据 等数据库收录!
点击此处可从《电测与仪表》浏览原始摘要信息
点击此处可从《电测与仪表》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号