摘    要:介绍了集中空调系统安装调试阶段的水质控制方法。采用化学清洗、钝化预膜和阻垢缓蚀的处理工艺,能使水质达到标准要求,降低铁的腐蚀速度,保证系统正常运行。

关 键 词:集中空调系统 正常运行 腐蚀速度 水质控制 安装调试 钝化 化学清洗 预膜 阻垢 缓蚀

Water quality control for central air conditioning systems
Cao Qin. Water quality control for central air conditioning systems[J]. Journal Heating Ventilating and Airconditioning, 2005, 35(3): 125-126,128
Authors:Cao Qin
Abstract:Presents the water quality control measures for central air conditioning systems during installation and commissioning periods. After the process of chemical cleaning, inactivating treatment and scale and corrosion inhibition, water quality can be improved to meet the standard requirement and corrosion rate of iron can be reduced, which assuring good running of the systems.